一种一体化的微流体低温保存系统和逐渐增加CPA浓度的方案。

IF 6.1 2区 工程技术 Q1 BIOCHEMICAL RESEARCH METHODS
Lab on a Chip Pub Date : 2025-01-16 DOI:10.1039/d4lc00888j
Tianhang Yang, Xinbei Lv, Yuqiao Bai, Huabin Jiang, Xiaoran Chang, Jinxian Wang, Gangyin Luo
{"title":"一种一体化的微流体低温保存系统和逐渐增加CPA浓度的方案。","authors":"Tianhang Yang, Xinbei Lv, Yuqiao Bai, Huabin Jiang, Xiaoran Chang, Jinxian Wang, Gangyin Luo","doi":"10.1039/d4lc00888j","DOIUrl":null,"url":null,"abstract":"<p><p>In regular biosample cryopreservation operations, dropwise pipetting and continuous swirling are ordinarily needed to prevent cell damage (<i>e.g.</i> sudden osmotic change, toxicity and dissolution heat) caused by the high-concentration cryoprotectant (CPA) addition process. The following CPA removal process after freezing and rewarming also requires multiple sample transfer processes and manual work. In order to optimize the cryopreservation process, especially for trace sample preservation, here we present a microfluidic approach integrating CPA addition, sample storage, CPA removal and sample resuspension processes on a 30 × 30 × 4 mm<sup>3</sup> three-layer chip. The sample solution could be added into CPA solution with pre-generated increasing concentration to decrease possible osmotic damage. Utilizing specially designed microfluidic structure and fluid field analysis, on-chip sample enrichment and CPA removal were achieved. A novel dead-end micro valve strategy with a simplified control module was applied and evaluated to assist on-chip mixing and sample pellet resuspension. The entire biosample cryopreservation process was also performed that verified the functions of the integrated microfluidic platform. Altogether, this developed platform could be an effective approach to realize automatic, all-in-one, low-damage cryopreservation operation.</p>","PeriodicalId":85,"journal":{"name":"Lab on a Chip","volume":" ","pages":""},"PeriodicalIF":6.1000,"publicationDate":"2025-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An all-in-one microfluidic cryopreservation system and protocols with gradually increasing CPA concentration.\",\"authors\":\"Tianhang Yang, Xinbei Lv, Yuqiao Bai, Huabin Jiang, Xiaoran Chang, Jinxian Wang, Gangyin Luo\",\"doi\":\"10.1039/d4lc00888j\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In regular biosample cryopreservation operations, dropwise pipetting and continuous swirling are ordinarily needed to prevent cell damage (<i>e.g.</i> sudden osmotic change, toxicity and dissolution heat) caused by the high-concentration cryoprotectant (CPA) addition process. The following CPA removal process after freezing and rewarming also requires multiple sample transfer processes and manual work. In order to optimize the cryopreservation process, especially for trace sample preservation, here we present a microfluidic approach integrating CPA addition, sample storage, CPA removal and sample resuspension processes on a 30 × 30 × 4 mm<sup>3</sup> three-layer chip. The sample solution could be added into CPA solution with pre-generated increasing concentration to decrease possible osmotic damage. Utilizing specially designed microfluidic structure and fluid field analysis, on-chip sample enrichment and CPA removal were achieved. A novel dead-end micro valve strategy with a simplified control module was applied and evaluated to assist on-chip mixing and sample pellet resuspension. The entire biosample cryopreservation process was also performed that verified the functions of the integrated microfluidic platform. Altogether, this developed platform could be an effective approach to realize automatic, all-in-one, low-damage cryopreservation operation.</p>\",\"PeriodicalId\":85,\"journal\":{\"name\":\"Lab on a Chip\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":6.1000,\"publicationDate\":\"2025-01-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lab on a Chip\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1039/d4lc00888j\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lab on a Chip","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1039/d4lc00888j","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

在常规的生物样品冷冻保存操作中,通常需要滴移液和连续旋转,以防止高浓度冷冻保护剂(CPA)添加过程引起的细胞损伤(例如突然渗透变化,毒性和溶解热)。下面的CPA在冷冻和再暖后的去除过程也需要多个样品转移过程和人工操作。为了优化低温保存工艺,特别是对微量样品的保存,我们提出了一种在30 × 30 × 4 mm3三层芯片上集成CPA添加、样品储存、CPA去除和样品重悬过程的微流控方法。将样品溶液加入到CPA溶液中,预先增加浓度,以减少可能的渗透损伤。利用特殊设计的微流控结构和流场分析,实现了片上样品富集和CPA去除。采用了一种具有简化控制模块的新型死端微阀策略,并对其进行了评估,以辅助片上混合和样品球团重悬。整个生物样品冷冻保存过程验证了集成微流控平台的功能。该平台是实现全自动、一体化、低损伤冷冻保存的有效途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An all-in-one microfluidic cryopreservation system and protocols with gradually increasing CPA concentration.

In regular biosample cryopreservation operations, dropwise pipetting and continuous swirling are ordinarily needed to prevent cell damage (e.g. sudden osmotic change, toxicity and dissolution heat) caused by the high-concentration cryoprotectant (CPA) addition process. The following CPA removal process after freezing and rewarming also requires multiple sample transfer processes and manual work. In order to optimize the cryopreservation process, especially for trace sample preservation, here we present a microfluidic approach integrating CPA addition, sample storage, CPA removal and sample resuspension processes on a 30 × 30 × 4 mm3 three-layer chip. The sample solution could be added into CPA solution with pre-generated increasing concentration to decrease possible osmotic damage. Utilizing specially designed microfluidic structure and fluid field analysis, on-chip sample enrichment and CPA removal were achieved. A novel dead-end micro valve strategy with a simplified control module was applied and evaluated to assist on-chip mixing and sample pellet resuspension. The entire biosample cryopreservation process was also performed that verified the functions of the integrated microfluidic platform. Altogether, this developed platform could be an effective approach to realize automatic, all-in-one, low-damage cryopreservation operation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Lab on a Chip
Lab on a Chip 工程技术-化学综合
CiteScore
11.10
自引率
8.20%
发文量
434
审稿时长
2.6 months
期刊介绍: Lab on a Chip is the premiere journal that publishes cutting-edge research in the field of miniaturization. By their very nature, microfluidic/nanofluidic/miniaturized systems are at the intersection of disciplines, spanning fundamental research to high-end application, which is reflected by the broad readership of the journal. Lab on a Chip publishes two types of papers on original research: full-length research papers and communications. Papers should demonstrate innovations, which can come from technical advancements or applications addressing pressing needs in globally important areas. The journal also publishes Comments, Reviews, and Perspectives.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信