开发和验证一种强大的单一提取方法,用于分析沿海环境中的多环芳烃,六溴环己烷,二溴二苯醚和多氯联苯。

IF 2.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Pooja Thathola, Hitesh T. Saravaia, Harshad Brahmbhatt, Sanak Roy and Soumya Haldar
{"title":"开发和验证一种强大的单一提取方法,用于分析沿海环境中的多环芳烃,六溴环己烷,二溴二苯醚和多氯联苯。","authors":"Pooja Thathola, Hitesh T. Saravaia, Harshad Brahmbhatt, Sanak Roy and Soumya Haldar","doi":"10.1039/D4AY02003K","DOIUrl":null,"url":null,"abstract":"<p >Monitoring persistent organic pollutants (POPs) with endocrine-disrupting properties poses significant analytical challenges due to labor-intensive, costly, and environmentally unsustainable procedures. This study developed an efficient and robust approach for the simultaneous detection of diverse groups of semi-volatile organics in water and sediment samples using gas chromatography-tandem mass spectrometry (GC-MS). Two extraction methods were studied for determining POPs in water and sediments. For water samples, the solid phase extraction (SPE) method was followed, while for sediments the sonication method was followed by using different solvents. The methods showed good accuracy, with recoveries of 96.41–100% for water and 85.65–100% for sediments, and relative standard deviations under 20%. In greywater, recoveries were 99.14–100% with a relative standard deviation under 18%, and in wastewater, recoveries were 90.52–98.63% with a relative standard deviation under 14%. Detection limits for water samples ranged from 0.023 to 0.037 μg L<small><sup>−1</sup></small>, while for sediments the detection limit ranges from 0.021 to 0.057 μg kg<small><sup>−1</sup></small>. These extraction methods are used to confirm the presence of POPs in environmental samples from the Gulf of Khambat, thereby validating their effectiveness and robustness for analyzing diverse environmental matrices and demonstrating their applicability in comprehensive environmental monitoring programs.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" 6","pages":" 1296-1305"},"PeriodicalIF":2.6000,"publicationDate":"2025-01-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development and validation of a robust single extraction method for analysis of PAHs, HBCD, BDE, and PCBs in the coastal environment†\",\"authors\":\"Pooja Thathola, Hitesh T. Saravaia, Harshad Brahmbhatt, Sanak Roy and Soumya Haldar\",\"doi\":\"10.1039/D4AY02003K\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Monitoring persistent organic pollutants (POPs) with endocrine-disrupting properties poses significant analytical challenges due to labor-intensive, costly, and environmentally unsustainable procedures. This study developed an efficient and robust approach for the simultaneous detection of diverse groups of semi-volatile organics in water and sediment samples using gas chromatography-tandem mass spectrometry (GC-MS). Two extraction methods were studied for determining POPs in water and sediments. For water samples, the solid phase extraction (SPE) method was followed, while for sediments the sonication method was followed by using different solvents. The methods showed good accuracy, with recoveries of 96.41–100% for water and 85.65–100% for sediments, and relative standard deviations under 20%. In greywater, recoveries were 99.14–100% with a relative standard deviation under 18%, and in wastewater, recoveries were 90.52–98.63% with a relative standard deviation under 14%. Detection limits for water samples ranged from 0.023 to 0.037 μg L<small><sup>−1</sup></small>, while for sediments the detection limit ranges from 0.021 to 0.057 μg kg<small><sup>−1</sup></small>. These extraction methods are used to confirm the presence of POPs in environmental samples from the Gulf of Khambat, thereby validating their effectiveness and robustness for analyzing diverse environmental matrices and demonstrating their applicability in comprehensive environmental monitoring programs.</p>\",\"PeriodicalId\":64,\"journal\":{\"name\":\"Analytical Methods\",\"volume\":\" 6\",\"pages\":\" 1296-1305\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2025-01-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Methods\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2025/ay/d4ay02003k\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ay/d4ay02003k","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

监测具有内分泌干扰特性的持久性有机污染物(POPs)由于劳动密集型、成本高且环境不可持续,给分析带来了重大挑战。本研究开发了一种高效可靠的方法,用于同时检测水和沉积物样品中不同类型的半挥发性有机物,使用气相色谱-串联质谱(GC-MS)。研究了两种提取方法对水中和沉积物中持久性有机污染物的测定。对水样采用固相萃取(SPE)法,对沉积物采用不同溶剂的超声法。结果表明,该方法准确度较高,水的回收率为96.41 ~ 100%,沉积物的回收率为85.65 ~ 100%,相对标准偏差在20%以下。在灰水中,回收率为99.14 ~ 100%,相对标准偏差小于18%;在废水中,回收率为90.52 ~ 98.63%,相对标准偏差小于14%。水样的检出限为0.023 ~ 0.037 μg -1,沉积物的检出限为0.021 ~ 0.057 μg -1。这些提取方法被用于确认来自汉巴特湾的环境样本中持久性有机污染物的存在,从而验证了它们在分析不同环境矩阵方面的有效性和稳健性,并证明了它们在综合环境监测计划中的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Development and validation of a robust single extraction method for analysis of PAHs, HBCD, BDE, and PCBs in the coastal environment†

Development and validation of a robust single extraction method for analysis of PAHs, HBCD, BDE, and PCBs in the coastal environment†

Monitoring persistent organic pollutants (POPs) with endocrine-disrupting properties poses significant analytical challenges due to labor-intensive, costly, and environmentally unsustainable procedures. This study developed an efficient and robust approach for the simultaneous detection of diverse groups of semi-volatile organics in water and sediment samples using gas chromatography-tandem mass spectrometry (GC-MS). Two extraction methods were studied for determining POPs in water and sediments. For water samples, the solid phase extraction (SPE) method was followed, while for sediments the sonication method was followed by using different solvents. The methods showed good accuracy, with recoveries of 96.41–100% for water and 85.65–100% for sediments, and relative standard deviations under 20%. In greywater, recoveries were 99.14–100% with a relative standard deviation under 18%, and in wastewater, recoveries were 90.52–98.63% with a relative standard deviation under 14%. Detection limits for water samples ranged from 0.023 to 0.037 μg L−1, while for sediments the detection limit ranges from 0.021 to 0.057 μg kg−1. These extraction methods are used to confirm the presence of POPs in environmental samples from the Gulf of Khambat, thereby validating their effectiveness and robustness for analyzing diverse environmental matrices and demonstrating their applicability in comprehensive environmental monitoring programs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信