金属诱导水解Tl3+离子的选择性荧光探针及其在人工尿液直接测定中的应用

IF 4.6 3区 化学 Q2 CHEMISTRY, MULTIDISCIPLINARY
RSC Advances Pub Date : 2025-01-15 DOI:10.1039/D4RA06726F
Myung Gil Choi, Yerin Jang, Mi Gang Kim, Sangdoo Ahn and Suk-Kyu Chang
{"title":"金属诱导水解Tl3+离子的选择性荧光探针及其在人工尿液直接测定中的应用","authors":"Myung Gil Choi, Yerin Jang, Mi Gang Kim, Sangdoo Ahn and Suk-Kyu Chang","doi":"10.1039/D4RA06726F","DOIUrl":null,"url":null,"abstract":"<p >In this research, we report a simple fluorescent probe designed to detect thallium(<small>III</small>) ions (Tl<small><sup>3+</sup></small>) in artificial urine samples. The Tl<small><sup>3+</sup></small> signaling probe (<strong>TP-1</strong>) was readily prepared from 2-acetyl-6-methoxynaphthalene and hydrazine. In a pH 4.8 acetate buffer solution containing 1% (v/v) <em>N</em>,<em>N</em>-dimethylformamide as a solubilizer, probe <strong>TP-1</strong> exhibited turn-on fluorescence signaling behavior in the presence of Tl<small><sup>3+</sup></small>. Other metal ions, anions, and major urine components such as uric acid, urea, and creatinine did not produce any noticeable fluorescence changes. The Tl<small><sup>3+</sup></small> signaling of <strong>TP-1</strong> was attributed to the hydrolysis of the hydrazone moiety, yielding the parent fluorophore 2-acetyl-6-methoxynaphthalene. The detection limit of <strong>TP-1</strong> for Tl<small><sup>3+</sup></small> sensing was 19 nM, and the signaling was completed within 2 min. Additionally, to further optimize the Tl<small><sup>3+</sup></small> signaling of the hydrazone derivatives, we compared the effect of structural variations between the closely related ketone-hydrazone (<strong>TP-1</strong>) and aldehyde-hydrazone (<strong>TP-2</strong>) derivatives. We confirmed that the ketone-hydrazone (<strong>TP-1</strong>) demonstrated rapid and stable Tl<small><sup>3+</sup></small> signaling behavior with satisfactory stability under the measurement conditions. Finally, as a practical application, a Tl<small><sup>3+</sup></small> assay in artificial urine samples was performed using a smartphone as a portable signaling measurement and data analysis device.</p>","PeriodicalId":102,"journal":{"name":"RSC Advances","volume":" 2","pages":" 1336-1343"},"PeriodicalIF":4.6000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2025/ra/d4ra06726f?page=search","citationCount":"0","resultStr":"{\"title\":\"Selective fluorescent probe for Tl3+ ions through metal-induced hydrolysis and its application for direct assay of artificial urine†\",\"authors\":\"Myung Gil Choi, Yerin Jang, Mi Gang Kim, Sangdoo Ahn and Suk-Kyu Chang\",\"doi\":\"10.1039/D4RA06726F\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >In this research, we report a simple fluorescent probe designed to detect thallium(<small>III</small>) ions (Tl<small><sup>3+</sup></small>) in artificial urine samples. The Tl<small><sup>3+</sup></small> signaling probe (<strong>TP-1</strong>) was readily prepared from 2-acetyl-6-methoxynaphthalene and hydrazine. In a pH 4.8 acetate buffer solution containing 1% (v/v) <em>N</em>,<em>N</em>-dimethylformamide as a solubilizer, probe <strong>TP-1</strong> exhibited turn-on fluorescence signaling behavior in the presence of Tl<small><sup>3+</sup></small>. Other metal ions, anions, and major urine components such as uric acid, urea, and creatinine did not produce any noticeable fluorescence changes. The Tl<small><sup>3+</sup></small> signaling of <strong>TP-1</strong> was attributed to the hydrolysis of the hydrazone moiety, yielding the parent fluorophore 2-acetyl-6-methoxynaphthalene. The detection limit of <strong>TP-1</strong> for Tl<small><sup>3+</sup></small> sensing was 19 nM, and the signaling was completed within 2 min. Additionally, to further optimize the Tl<small><sup>3+</sup></small> signaling of the hydrazone derivatives, we compared the effect of structural variations between the closely related ketone-hydrazone (<strong>TP-1</strong>) and aldehyde-hydrazone (<strong>TP-2</strong>) derivatives. We confirmed that the ketone-hydrazone (<strong>TP-1</strong>) demonstrated rapid and stable Tl<small><sup>3+</sup></small> signaling behavior with satisfactory stability under the measurement conditions. Finally, as a practical application, a Tl<small><sup>3+</sup></small> assay in artificial urine samples was performed using a smartphone as a portable signaling measurement and data analysis device.</p>\",\"PeriodicalId\":102,\"journal\":{\"name\":\"RSC Advances\",\"volume\":\" 2\",\"pages\":\" 1336-1343\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2025-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://pubs.rsc.org/en/content/articlepdf/2025/ra/d4ra06726f?page=search\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"RSC Advances\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2025/ra/d4ra06726f\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"RSC Advances","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ra/d4ra06726f","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

在这项研究中,我们报道了一种简单的荧光探针,用于检测人工尿液样本中的铊(III)离子(Tl3+)。Tl3+信号探针(TP-1)由2-乙酰基-6-甲氧基萘和肼制备而成。在pH为4.8的醋酸缓冲溶液中,含有1% (v/v) N,N-二甲基甲酰胺作为增溶剂,探针TP-1在Tl3+存在下表现出开启荧光信号行为。其他金属离子、阴离子和尿液的主要成分如尿酸、尿素和肌酐没有产生任何明显的荧光变化。TP-1的Tl3+信号传导归因于腙部分的水解,产生亲本荧光基团2-乙酰基-6-甲氧基萘。TP-1对Tl3+传感的检出限为19 nM,在2 min内完成信号传递。此外,为了进一步优化腙衍生物的Tl3+信号传递,我们比较了密切相关的酮腙(TP-1)和醛腙(TP-2)衍生物之间结构变化的影响。我们证实了酮腙(TP-1)在测量条件下表现出快速稳定的Tl3+信号行为,具有令人满意的稳定性。最后,作为实际应用,使用智能手机作为便携式信号测量和数据分析设备,对人工尿液样本进行Tl3+检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Selective fluorescent probe for Tl3+ ions through metal-induced hydrolysis and its application for direct assay of artificial urine†

Selective fluorescent probe for Tl3+ ions through metal-induced hydrolysis and its application for direct assay of artificial urine†

In this research, we report a simple fluorescent probe designed to detect thallium(III) ions (Tl3+) in artificial urine samples. The Tl3+ signaling probe (TP-1) was readily prepared from 2-acetyl-6-methoxynaphthalene and hydrazine. In a pH 4.8 acetate buffer solution containing 1% (v/v) N,N-dimethylformamide as a solubilizer, probe TP-1 exhibited turn-on fluorescence signaling behavior in the presence of Tl3+. Other metal ions, anions, and major urine components such as uric acid, urea, and creatinine did not produce any noticeable fluorescence changes. The Tl3+ signaling of TP-1 was attributed to the hydrolysis of the hydrazone moiety, yielding the parent fluorophore 2-acetyl-6-methoxynaphthalene. The detection limit of TP-1 for Tl3+ sensing was 19 nM, and the signaling was completed within 2 min. Additionally, to further optimize the Tl3+ signaling of the hydrazone derivatives, we compared the effect of structural variations between the closely related ketone-hydrazone (TP-1) and aldehyde-hydrazone (TP-2) derivatives. We confirmed that the ketone-hydrazone (TP-1) demonstrated rapid and stable Tl3+ signaling behavior with satisfactory stability under the measurement conditions. Finally, as a practical application, a Tl3+ assay in artificial urine samples was performed using a smartphone as a portable signaling measurement and data analysis device.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
RSC Advances
RSC Advances chemical sciences-
CiteScore
7.50
自引率
2.60%
发文量
3116
审稿时长
1.6 months
期刊介绍: An international, peer-reviewed journal covering all of the chemical sciences, including multidisciplinary and emerging areas. RSC Advances is a gold open access journal allowing researchers free access to research articles, and offering an affordable open access publishing option for authors around the world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信