Nikol Gottfriedová, Michaela Škerková, Martina Zbořilová, Martina Kovalová, Hana Tomaskova, Eva Mrázková
{"title":"青少年个人听力设备使用者在常规高频和扩展高频的听力阈值:一项初步研究。","authors":"Nikol Gottfriedová, Michaela Škerková, Martina Zbořilová, Martina Kovalová, Hana Tomaskova, Eva Mrázková","doi":"10.5604/01.3001.0054.8776","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> The exposure to unsafe sound levels is considered a risk factor for developing noise-induced hearing loss (NIHL). Personal listening devices (PLDs) represent a common source of recreational noise among young adults. First changes of NIHL could be detected at extended high frequencies (EHFs).<b>Aim:</b> This pilot study aimed to analyze hearing thresholds at conventional frequencies (CFs) and EHFs in young adults due to the PLD use.<b>Methods:</b> Hearing thresholds of 114 otologically normal adults aged 18 to 30 years unexposed to occupational noise were assessed using conventional and extended high-frequency audiometry. Data on PLD use, leisure time noise exposure, health and lifestyle, were acquired using a questionnaire.<b>Results:</b> Differences in hearing thresholds were found at CFs but not at EHFs according to the listening frequency (daily vs less frequent listening); duration of one PLD use of more than 30 minutes; and total listening time ≥7 hours/week. Only the highest frequency was affected by loud volume listening.<b>Conclusions:</b> Changes in hearing thresholds were found at CFs, whereby long duration, high volume and daily use were associated with lower hearing thresholds in otologically healthy adults.</p>","PeriodicalId":42608,"journal":{"name":"Polish Journal of Otolaryngology","volume":"79 1","pages":"1-9"},"PeriodicalIF":1.0000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Hearing thresholds at conventional and extended high frequencies in young personal listening devices' users: A pilot study.\",\"authors\":\"Nikol Gottfriedová, Michaela Škerková, Martina Zbořilová, Martina Kovalová, Hana Tomaskova, Eva Mrázková\",\"doi\":\"10.5604/01.3001.0054.8776\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Introduction:</b> The exposure to unsafe sound levels is considered a risk factor for developing noise-induced hearing loss (NIHL). Personal listening devices (PLDs) represent a common source of recreational noise among young adults. First changes of NIHL could be detected at extended high frequencies (EHFs).<b>Aim:</b> This pilot study aimed to analyze hearing thresholds at conventional frequencies (CFs) and EHFs in young adults due to the PLD use.<b>Methods:</b> Hearing thresholds of 114 otologically normal adults aged 18 to 30 years unexposed to occupational noise were assessed using conventional and extended high-frequency audiometry. Data on PLD use, leisure time noise exposure, health and lifestyle, were acquired using a questionnaire.<b>Results:</b> Differences in hearing thresholds were found at CFs but not at EHFs according to the listening frequency (daily vs less frequent listening); duration of one PLD use of more than 30 minutes; and total listening time ≥7 hours/week. Only the highest frequency was affected by loud volume listening.<b>Conclusions:</b> Changes in hearing thresholds were found at CFs, whereby long duration, high volume and daily use were associated with lower hearing thresholds in otologically healthy adults.</p>\",\"PeriodicalId\":42608,\"journal\":{\"name\":\"Polish Journal of Otolaryngology\",\"volume\":\"79 1\",\"pages\":\"1-9\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2025-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polish Journal of Otolaryngology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5604/01.3001.0054.8776\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Otolaryngology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0054.8776","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
Hearing thresholds at conventional and extended high frequencies in young personal listening devices' users: A pilot study.
<b>Introduction:</b> The exposure to unsafe sound levels is considered a risk factor for developing noise-induced hearing loss (NIHL). Personal listening devices (PLDs) represent a common source of recreational noise among young adults. First changes of NIHL could be detected at extended high frequencies (EHFs).<b>Aim:</b> This pilot study aimed to analyze hearing thresholds at conventional frequencies (CFs) and EHFs in young adults due to the PLD use.<b>Methods:</b> Hearing thresholds of 114 otologically normal adults aged 18 to 30 years unexposed to occupational noise were assessed using conventional and extended high-frequency audiometry. Data on PLD use, leisure time noise exposure, health and lifestyle, were acquired using a questionnaire.<b>Results:</b> Differences in hearing thresholds were found at CFs but not at EHFs according to the listening frequency (daily vs less frequent listening); duration of one PLD use of more than 30 minutes; and total listening time ≥7 hours/week. Only the highest frequency was affected by loud volume listening.<b>Conclusions:</b> Changes in hearing thresholds were found at CFs, whereby long duration, high volume and daily use were associated with lower hearing thresholds in otologically healthy adults.