Keenan O Hogan, Geethanjalee Mudunkotuwa, Milind Phadnis, X Long Zheng, Zhan Ye
{"title":"ABO 不相容和成分辐照与血小板输血反应率独立相关。","authors":"Keenan O Hogan, Geethanjalee Mudunkotuwa, Milind Phadnis, X Long Zheng, Zhan Ye","doi":"10.1111/trf.18130","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Allocating incompatible platelet components to avoid product wastage must be balanced against the risk of reduced efficacy and adverse outcomes. The impact of platelet compatibility in association with product irradiation or pathogen reduction is unknown. This study aims to determine the combined and independent impact of platelet compatibility and component modification on transfusion reaction rate.</p><p><strong>Study design and methods: </strong>A retrospective review of all adult platelet transfusions from 2020 to 2022 was performed, including all reported reactions. Logistic regression was performed to evaluate the significance of ABO compatibility and unit modification for reaction rate.</p><p><strong>Results: </strong>Out of 21,330 transfusions to 3450 patients, 285 (1.33%) reactions were reported and 178 (0.83%) were diagnosed as related to transfusion, predominantly febrile nonhemolytic (n = 59) and allergic (n = 102). The compatibility of transfusion was 67.7% ABO identical, 13.8% ABO minor incompatible, 17.2% ABO major incompatible, and 1.4% ABO bidirectionally incompatible. Irradiated, unmodified, and pathogen-reduced single-donor platelets were transfused in 70.9%, 21.8%, and 7.3% of cases, respectively. Univariable regression demonstrated increased odds of reaction for major incompatibility vs. ABO identical (OR: 1.92; 95% CI: 1.36-2.71) and irradiated vs. unmodified (OR: 2.34; 95% CI: 1.45-3.91), which were confirmed by multivariable analysis. The effect of compatibility and unit modification were independent in all analyses.</p><p><strong>Conclusions: </strong>The results demonstrate a trend of increasing reaction rate associated with major incompatibility and product irradiation. This study provides additional data to inform institutional policies guiding product selection for individual patients.</p>","PeriodicalId":23266,"journal":{"name":"Transfusion","volume":" ","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2025-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ABO incompatibility and component irradiation are independently associated with platelet transfusion reaction rate.\",\"authors\":\"Keenan O Hogan, Geethanjalee Mudunkotuwa, Milind Phadnis, X Long Zheng, Zhan Ye\",\"doi\":\"10.1111/trf.18130\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Allocating incompatible platelet components to avoid product wastage must be balanced against the risk of reduced efficacy and adverse outcomes. The impact of platelet compatibility in association with product irradiation or pathogen reduction is unknown. This study aims to determine the combined and independent impact of platelet compatibility and component modification on transfusion reaction rate.</p><p><strong>Study design and methods: </strong>A retrospective review of all adult platelet transfusions from 2020 to 2022 was performed, including all reported reactions. Logistic regression was performed to evaluate the significance of ABO compatibility and unit modification for reaction rate.</p><p><strong>Results: </strong>Out of 21,330 transfusions to 3450 patients, 285 (1.33%) reactions were reported and 178 (0.83%) were diagnosed as related to transfusion, predominantly febrile nonhemolytic (n = 59) and allergic (n = 102). The compatibility of transfusion was 67.7% ABO identical, 13.8% ABO minor incompatible, 17.2% ABO major incompatible, and 1.4% ABO bidirectionally incompatible. Irradiated, unmodified, and pathogen-reduced single-donor platelets were transfused in 70.9%, 21.8%, and 7.3% of cases, respectively. Univariable regression demonstrated increased odds of reaction for major incompatibility vs. ABO identical (OR: 1.92; 95% CI: 1.36-2.71) and irradiated vs. unmodified (OR: 2.34; 95% CI: 1.45-3.91), which were confirmed by multivariable analysis. The effect of compatibility and unit modification were independent in all analyses.</p><p><strong>Conclusions: </strong>The results demonstrate a trend of increasing reaction rate associated with major incompatibility and product irradiation. This study provides additional data to inform institutional policies guiding product selection for individual patients.</p>\",\"PeriodicalId\":23266,\"journal\":{\"name\":\"Transfusion\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2025-01-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transfusion\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/trf.18130\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transfusion","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/trf.18130","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:分配不相容的血小板成分以避免产品浪费必须与降低疗效和不良后果的风险相平衡。血小板相容性与产品辐照或病原体减少相关的影响尚不清楚。本研究旨在确定血小板相容性和组分修饰对输血反应率的联合和独立影响。研究设计和方法:对2020年至2022年所有成人血小板输注进行回顾性分析,包括所有报告的反应。采用Logistic回归分析ABO相容性和单位修饰对反应速率的影响。结果:在3450例患者的21330例输血中,报告了285例(1.33%)反应,178例(0.83%)诊断为与输血有关,主要是发热性非溶血性(n = 59)和过敏性(n = 102)。输血相容性为:血型相同67.7%,血型次要不相容13.8%,血型主要不相容17.2%,血型双向不相容1.4%。照射过的、未修饰的和病原体减少的单供者血小板输注率分别为70.9%、21.8%和7.3%。单变量回归显示,与ABO血型相同的患者相比,主要不相容患者的反应几率增加(OR: 1.92;95% CI: 1.36-2.71)和辐照vs.未修饰(OR: 2.34;95% CI: 1.45-3.91),经多变量分析证实。在所有的分析中,配伍性和单位修饰的影响是独立的。结论:反应速率的增加与主要不相容性和产物辐照有关。本研究提供了额外的数据,为指导个别患者的产品选择的机构政策提供信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
ABO incompatibility and component irradiation are independently associated with platelet transfusion reaction rate.

Background: Allocating incompatible platelet components to avoid product wastage must be balanced against the risk of reduced efficacy and adverse outcomes. The impact of platelet compatibility in association with product irradiation or pathogen reduction is unknown. This study aims to determine the combined and independent impact of platelet compatibility and component modification on transfusion reaction rate.

Study design and methods: A retrospective review of all adult platelet transfusions from 2020 to 2022 was performed, including all reported reactions. Logistic regression was performed to evaluate the significance of ABO compatibility and unit modification for reaction rate.

Results: Out of 21,330 transfusions to 3450 patients, 285 (1.33%) reactions were reported and 178 (0.83%) were diagnosed as related to transfusion, predominantly febrile nonhemolytic (n = 59) and allergic (n = 102). The compatibility of transfusion was 67.7% ABO identical, 13.8% ABO minor incompatible, 17.2% ABO major incompatible, and 1.4% ABO bidirectionally incompatible. Irradiated, unmodified, and pathogen-reduced single-donor platelets were transfused in 70.9%, 21.8%, and 7.3% of cases, respectively. Univariable regression demonstrated increased odds of reaction for major incompatibility vs. ABO identical (OR: 1.92; 95% CI: 1.36-2.71) and irradiated vs. unmodified (OR: 2.34; 95% CI: 1.45-3.91), which were confirmed by multivariable analysis. The effect of compatibility and unit modification were independent in all analyses.

Conclusions: The results demonstrate a trend of increasing reaction rate associated with major incompatibility and product irradiation. This study provides additional data to inform institutional policies guiding product selection for individual patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Transfusion
Transfusion 医学-血液学
CiteScore
4.70
自引率
20.70%
发文量
426
审稿时长
1 months
期刊介绍: TRANSFUSION is the foremost publication in the world for new information regarding transfusion medicine. Written by and for members of AABB and other health-care workers, TRANSFUSION reports on the latest technical advances, discusses opposing viewpoints regarding controversial issues, and presents key conference proceedings. In addition to blood banking and transfusion medicine topics, TRANSFUSION presents submissions concerning patient blood management, tissue transplantation and hematopoietic, cellular, and gene therapies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信