中国电子血压计的验证状况:全国调查。

IF 6.9 1区 医学 Q1 PERIPHERAL VASCULAR DISEASE
Xianghui Zhang, Zhimin Xu, Yingchun Yao, Huilei Zheng, Jian Wu, Jingwen Hu, Shenggen Wu, Quanjun Lyu, Yong Liu, Min Wu, Liangxia Chen, Lina Xu, Haiyan Zhou, Peifen Duan, Jianghong Dai, Hong Ding, Shuang Wang, Yi Zhao, Jihong Hu, Liyue Zhu, Rong Hai, Baoliang Zhong, Huilian Zhu, Kui Li, Yao Lu, Shaowen Tang, Xingming Li, Yan Zhang, Zongtao Chen, Tongyu Wang, Mei Li, Fuxu Liu, Chengluan Liu, Xiaoling Yang, Lihua Dong, Jixiang Ma, Pei Gao, Wuxiang Xie, Yangfeng Wu
{"title":"中国电子血压计的验证状况:全国调查。","authors":"Xianghui Zhang, Zhimin Xu, Yingchun Yao, Huilei Zheng, Jian Wu, Jingwen Hu, Shenggen Wu, Quanjun Lyu, Yong Liu, Min Wu, Liangxia Chen, Lina Xu, Haiyan Zhou, Peifen Duan, Jianghong Dai, Hong Ding, Shuang Wang, Yi Zhao, Jihong Hu, Liyue Zhu, Rong Hai, Baoliang Zhong, Huilian Zhu, Kui Li, Yao Lu, Shaowen Tang, Xingming Li, Yan Zhang, Zongtao Chen, Tongyu Wang, Mei Li, Fuxu Liu, Chengluan Liu, Xiaoling Yang, Lihua Dong, Jixiang Ma, Pei Gao, Wuxiang Xie, Yangfeng Wu","doi":"10.1161/HYPERTENSIONAHA.124.24203","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Although the information on the validation status of electronic sphygmomanometer (ES) devices in use in health care institutions and households is much more clinically relevant than that of ES models available on the market, it remains insufficient.</p><p><strong>Methods: </strong>A national survey was conducted across all administrative regions of mainland China to assess the validation status of ESs. Fifty-eight cities were selected with stratification by municipality, provincial capital, and other cities, and health care institutions and households in each city were chosen by convenience to identify ES devices in use according to the study protocol. Information on devices' model, type, was collected. The validation status of each device was ascertained through searching international online registries of its models.</p><p><strong>Results: </strong>A total of 3230 ES devices (1924 from health care institutions and 1306 from households), encompassing 498 ES models, were actually selected. The weighted proportion of accuracy-validated devices was significantly higher in health care institutions (33.9% [95% CI, 31.8-36.0%]) compared with households (23.0% [95% CI, 20.8-25.4%]; <i>P</i><0.001), and both exceeded the proportions for models (17.7% [95% CI, 13.7-22.6%] and 12.5% [95% CI, 9.5-16.3%], respectively). Regional economic development, device type, and years in use were associated with the proportion of accuracy-validated devices. Notably, 8.8% of devices used in secondary hospitals were wrist type.</p><p><strong>Conclusions: </strong>The accuracy validation status of ESs in China in the number of devices in use shows a more favorable situation than that in the number of models but remains low and concerning. Policies are urgently needed to promote the widespread adoption of accuracy-validated models among all users.</p>","PeriodicalId":13042,"journal":{"name":"Hypertension","volume":" ","pages":""},"PeriodicalIF":6.9000,"publicationDate":"2025-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation Status of Electronic Sphygmomanometers in China: A National Survey.\",\"authors\":\"Xianghui Zhang, Zhimin Xu, Yingchun Yao, Huilei Zheng, Jian Wu, Jingwen Hu, Shenggen Wu, Quanjun Lyu, Yong Liu, Min Wu, Liangxia Chen, Lina Xu, Haiyan Zhou, Peifen Duan, Jianghong Dai, Hong Ding, Shuang Wang, Yi Zhao, Jihong Hu, Liyue Zhu, Rong Hai, Baoliang Zhong, Huilian Zhu, Kui Li, Yao Lu, Shaowen Tang, Xingming Li, Yan Zhang, Zongtao Chen, Tongyu Wang, Mei Li, Fuxu Liu, Chengluan Liu, Xiaoling Yang, Lihua Dong, Jixiang Ma, Pei Gao, Wuxiang Xie, Yangfeng Wu\",\"doi\":\"10.1161/HYPERTENSIONAHA.124.24203\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Although the information on the validation status of electronic sphygmomanometer (ES) devices in use in health care institutions and households is much more clinically relevant than that of ES models available on the market, it remains insufficient.</p><p><strong>Methods: </strong>A national survey was conducted across all administrative regions of mainland China to assess the validation status of ESs. Fifty-eight cities were selected with stratification by municipality, provincial capital, and other cities, and health care institutions and households in each city were chosen by convenience to identify ES devices in use according to the study protocol. Information on devices' model, type, was collected. The validation status of each device was ascertained through searching international online registries of its models.</p><p><strong>Results: </strong>A total of 3230 ES devices (1924 from health care institutions and 1306 from households), encompassing 498 ES models, were actually selected. The weighted proportion of accuracy-validated devices was significantly higher in health care institutions (33.9% [95% CI, 31.8-36.0%]) compared with households (23.0% [95% CI, 20.8-25.4%]; <i>P</i><0.001), and both exceeded the proportions for models (17.7% [95% CI, 13.7-22.6%] and 12.5% [95% CI, 9.5-16.3%], respectively). Regional economic development, device type, and years in use were associated with the proportion of accuracy-validated devices. Notably, 8.8% of devices used in secondary hospitals were wrist type.</p><p><strong>Conclusions: </strong>The accuracy validation status of ESs in China in the number of devices in use shows a more favorable situation than that in the number of models but remains low and concerning. Policies are urgently needed to promote the widespread adoption of accuracy-validated models among all users.</p>\",\"PeriodicalId\":13042,\"journal\":{\"name\":\"Hypertension\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":6.9000,\"publicationDate\":\"2025-01-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hypertension\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1161/HYPERTENSIONAHA.124.24203\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hypertension","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/HYPERTENSIONAHA.124.24203","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

背景:尽管医疗机构和家庭中使用的电子血压计(ES)设备的验证状况信息比市场上的ES型号更贴近临床,但仍然不够充分:方法:在中国大陆所有行政区域开展了一项全国性调查,以评估电子血压计的验证情况。按直辖市、省会城市和其他城市分层选择了 58 个城市,并根据研究方案在每个城市的医疗机构和家庭中方便地选择了正在使用的 ES 设备。收集设备的型号、类型等信息。通过搜索国际在线登记册中的型号,确定每种设备的验证状态:实际共选取了 3230 台 ES 设备(1924 台来自医疗机构,1306 台来自家庭),包括 498 种 ES 型号。与家庭(23.0% [95% CI, 20.8-25.4%])相比,医疗机构的加权准确性验证设备比例(33.9% [95% CI, 31.8-36.0%])明显更高:与模型数量相比,中国在使用设备数量方面的准确性验证情况更为有利,但仍处于较低水平,令人担忧。亟需制定相关政策,促进所有用户广泛采用经过准确性验证的模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validation Status of Electronic Sphygmomanometers in China: A National Survey.

Background: Although the information on the validation status of electronic sphygmomanometer (ES) devices in use in health care institutions and households is much more clinically relevant than that of ES models available on the market, it remains insufficient.

Methods: A national survey was conducted across all administrative regions of mainland China to assess the validation status of ESs. Fifty-eight cities were selected with stratification by municipality, provincial capital, and other cities, and health care institutions and households in each city were chosen by convenience to identify ES devices in use according to the study protocol. Information on devices' model, type, was collected. The validation status of each device was ascertained through searching international online registries of its models.

Results: A total of 3230 ES devices (1924 from health care institutions and 1306 from households), encompassing 498 ES models, were actually selected. The weighted proportion of accuracy-validated devices was significantly higher in health care institutions (33.9% [95% CI, 31.8-36.0%]) compared with households (23.0% [95% CI, 20.8-25.4%]; P<0.001), and both exceeded the proportions for models (17.7% [95% CI, 13.7-22.6%] and 12.5% [95% CI, 9.5-16.3%], respectively). Regional economic development, device type, and years in use were associated with the proportion of accuracy-validated devices. Notably, 8.8% of devices used in secondary hospitals were wrist type.

Conclusions: The accuracy validation status of ESs in China in the number of devices in use shows a more favorable situation than that in the number of models but remains low and concerning. Policies are urgently needed to promote the widespread adoption of accuracy-validated models among all users.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Hypertension
Hypertension 医学-外周血管病
CiteScore
15.90
自引率
4.80%
发文量
1006
审稿时长
1 months
期刊介绍: Hypertension presents top-tier articles on high blood pressure in each monthly release. These articles delve into basic science, clinical treatment, and prevention of hypertension and associated cardiovascular, metabolic, and renal conditions. Renowned for their lasting significance, these papers contribute to advancing our understanding and management of hypertension-related issues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信