Lucia Gomez Prieto, Dominic Byron-Chance, Ashton J Hollwarth, Thomas A G Dutton
{"title":"有意识的成年埃及秃鹫(Neophron percnopterus)的回弹眼压测量参考值。","authors":"Lucia Gomez Prieto, Dominic Byron-Chance, Ashton J Hollwarth, Thomas A G Dutton","doi":"10.2460/ajvr.24.10.0308","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To obtain standard reference values of intraocular pressure measured with rebound tonometry in conscious healthy Egyptian vultures (Neophron percnopterus).</p><p><strong>Methods: </strong>17 Egyptian vultures presented for a routine health check, involving a full physical examination, blood film examination, Hct, manual total leukocyte count, and plasma biochemistry. 15 animals considered healthy and with no signs of stress underwent an ophthalmic examination, including observation of facial symmetry, adnexa, and direct fundoscopy to screen for ocular disease. Healthy animals, with no evidence of ocular disease and no signs of stress, were included in the study. The birds were manually restraint in an upright position for rebound tonometry of the right and left eyes.</p><p><strong>Results: </strong>Mean and SD of intraocular pressure were 27.33 ± 3.54 mm Hg for the right eye and 27.00 ± 4.11 mm Hg for the left eye. There was no statistical difference when comparing the right and left eyes. The combined mean ± SD for both eyes was 27.2 ± 3.76 mm Hg.</p><p><strong>Conclusions: </strong>Rebound tonometry was well tolerated in all animals included in the study. The results of intraocular pressure with rebound tonometry can be used as reference values during the ophthalmological examination of Egyptian vultures.</p><p><strong>Clinical relevance: </strong>The investigation of vision threatening diseases in Egyptian vultures may necessitate rebound tonometry as part of a comprehensive ophthalmologic examination. Rebound tonometry values obtained from anesthetized Egyptian vultures, or Egyptian vultures restrained in lateral, dorsal, or sternal positions, may differ from those reported here.</p>","PeriodicalId":7754,"journal":{"name":"American journal of veterinary research","volume":" ","pages":"1-6"},"PeriodicalIF":1.3000,"publicationDate":"2025-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rebound tonometry intraocular pressure reference values for conscious adult Egyptian vultures (Neophron percnopterus).\",\"authors\":\"Lucia Gomez Prieto, Dominic Byron-Chance, Ashton J Hollwarth, Thomas A G Dutton\",\"doi\":\"10.2460/ajvr.24.10.0308\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To obtain standard reference values of intraocular pressure measured with rebound tonometry in conscious healthy Egyptian vultures (Neophron percnopterus).</p><p><strong>Methods: </strong>17 Egyptian vultures presented for a routine health check, involving a full physical examination, blood film examination, Hct, manual total leukocyte count, and plasma biochemistry. 15 animals considered healthy and with no signs of stress underwent an ophthalmic examination, including observation of facial symmetry, adnexa, and direct fundoscopy to screen for ocular disease. Healthy animals, with no evidence of ocular disease and no signs of stress, were included in the study. The birds were manually restraint in an upright position for rebound tonometry of the right and left eyes.</p><p><strong>Results: </strong>Mean and SD of intraocular pressure were 27.33 ± 3.54 mm Hg for the right eye and 27.00 ± 4.11 mm Hg for the left eye. There was no statistical difference when comparing the right and left eyes. The combined mean ± SD for both eyes was 27.2 ± 3.76 mm Hg.</p><p><strong>Conclusions: </strong>Rebound tonometry was well tolerated in all animals included in the study. The results of intraocular pressure with rebound tonometry can be used as reference values during the ophthalmological examination of Egyptian vultures.</p><p><strong>Clinical relevance: </strong>The investigation of vision threatening diseases in Egyptian vultures may necessitate rebound tonometry as part of a comprehensive ophthalmologic examination. Rebound tonometry values obtained from anesthetized Egyptian vultures, or Egyptian vultures restrained in lateral, dorsal, or sternal positions, may differ from those reported here.</p>\",\"PeriodicalId\":7754,\"journal\":{\"name\":\"American journal of veterinary research\",\"volume\":\" \",\"pages\":\"1-6\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-01-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of veterinary research\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.2460/ajvr.24.10.0308\",\"RegionNum\":3,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of veterinary research","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.2460/ajvr.24.10.0308","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
摘要
目的方法:对 17 只埃及秃鹫进行常规健康检查,包括全面体格检查、血片检查、眼压、人工白细胞总数和血浆生化检查。15只被认为健康且无应激迹象的动物接受了眼科检查,包括观察面部对称性、附件和直接眼底镜检查,以筛查眼部疾病。没有眼部疾病和应激迹象的健康动物被纳入研究范围。人工将鸟类束缚在直立位置,对左右眼进行眼压回弹测量:结果:右眼和左眼眼压的平均值和标度分别为 27.33 ± 3.54 mm Hg 和 27.00 ± 4.11 mm Hg。左右眼比较无统计学差异。双眼的综合平均值(±SD)为 27.2 ± 3.76 mm Hg:结论:所有参与研究的动物都能很好地耐受反弹式眼压测量法。回弹式眼压计的眼压结果可作为埃及秃鹫眼科检查的参考值:临床意义:在对埃及秃鹫进行视力威胁性疾病检查时,可能需要将反弹式眼压测量法作为眼科综合检查的一部分。从麻醉的埃及秃鹫或在侧位、背位或胸骨位受约束的埃及秃鹫身上获得的回弹眼压测量值可能与此处报告的数值不同。
Objective: To obtain standard reference values of intraocular pressure measured with rebound tonometry in conscious healthy Egyptian vultures (Neophron percnopterus).
Methods: 17 Egyptian vultures presented for a routine health check, involving a full physical examination, blood film examination, Hct, manual total leukocyte count, and plasma biochemistry. 15 animals considered healthy and with no signs of stress underwent an ophthalmic examination, including observation of facial symmetry, adnexa, and direct fundoscopy to screen for ocular disease. Healthy animals, with no evidence of ocular disease and no signs of stress, were included in the study. The birds were manually restraint in an upright position for rebound tonometry of the right and left eyes.
Results: Mean and SD of intraocular pressure were 27.33 ± 3.54 mm Hg for the right eye and 27.00 ± 4.11 mm Hg for the left eye. There was no statistical difference when comparing the right and left eyes. The combined mean ± SD for both eyes was 27.2 ± 3.76 mm Hg.
Conclusions: Rebound tonometry was well tolerated in all animals included in the study. The results of intraocular pressure with rebound tonometry can be used as reference values during the ophthalmological examination of Egyptian vultures.
Clinical relevance: The investigation of vision threatening diseases in Egyptian vultures may necessitate rebound tonometry as part of a comprehensive ophthalmologic examination. Rebound tonometry values obtained from anesthetized Egyptian vultures, or Egyptian vultures restrained in lateral, dorsal, or sternal positions, may differ from those reported here.
期刊介绍:
The American Journal of Veterinary Research supports the collaborative exchange of information between researchers and clinicians by publishing novel research findings that bridge the gulf between basic research and clinical practice or that help to translate laboratory research and preclinical studies to the development of clinical trials and clinical practice. The journal welcomes submission of high-quality original studies and review articles in a wide range of scientific fields, including anatomy, anesthesiology, animal welfare, behavior, epidemiology, genetics, heredity, infectious disease, molecular biology, oncology, pharmacology, pathogenic mechanisms, physiology, surgery, theriogenology, toxicology, and vaccinology. Species of interest include production animals, companion animals, equids, exotic animals, birds, reptiles, and wild and marine animals. Reports of laboratory animal studies and studies involving the use of animals as experimental models of human diseases are considered only when the study results are of demonstrable benefit to the species used in the research or to another species of veterinary interest. Other fields of interest or animals species are not necessarily excluded from consideration, but such reports must focus on novel research findings. Submitted papers must make an original and substantial contribution to the veterinary medicine knowledge base; preliminary studies are not appropriate.