在不同拧紧力矩下评估四种不同互锁的种植体系统的微间隙和密封能力:一项体外研究。

IF 2.7 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Advanced Prosthodontics Pub Date : 2024-12-01 Epub Date: 2024-12-19 DOI:10.4047/jap.2024.16.6.336
Mohammed Assayed Mousa, Hasna Alshubrmi, Rakhi Issrani, Bader Kureyem Alzarea
{"title":"在不同拧紧力矩下评估四种不同互锁的种植体系统的微间隙和密封能力:一项体外研究。","authors":"Mohammed Assayed Mousa, Hasna Alshubrmi, Rakhi Issrani, Bader Kureyem Alzarea","doi":"10.4047/jap.2024.16.6.336","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study assessed the microgap width and adhesion of three bacterial species in four dental implants with different interlocks under four screwing torques.</p><p><strong>Materials and methods: </strong>Ten samples of four implant systems with various interlockings, including full-hexagonal (FHI), cylindrical-conical trilobe-index (TLI), Morse-taper with octagon terminal index (OI), and hexagonal interlock (slip-fit) (HI-SF), were used. The abutments were screwed to the fixtures under torques of 10, 20, 30, and 40 Ncm. The microgap between the abutment and the platform was assessed using a Scanning Electron Microscope (SEM). The leakage of 3 bacteria, including Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa, was evaluated under 30 Ncm torque.</p><p><strong>Results: </strong>The TLI system showed the widest gap under all torques compared to others. There was no significance among all systems under different screwing torques. Regarding the leakage, there was no adherence to <i>E. coli</i> and <i>S. aureus</i> and 36.4% of <i>Ps. aeruginosa</i> to the HI-SF, followed by the OI system. The FHI and TLI systems showed the highest bacterial adherence.</p><p><strong>Conclusion: </strong>Even with low torque, the studied systems showed gap widths narrower than acceptable width. Implant systems with FHI and OI demonstrated misfits of less than 2 µm upon 10 Ncm and less than 1 µm when the torque increases, giving them priority to be used in areas with poor bone quality. The HI-SF demonstrated a high ability to resist the adherence to <i>E. coli</i> and <i>S. aureus</i>, followed by OI. However, <i>Ps. aeruginosa</i> demonstrated a high ability to adhere to all systems.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"16 6","pages":"336-347"},"PeriodicalIF":2.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11711449/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluating the microgap and sealing capability in four implant systems with different interlockings under different tightening torques: an <i>in-vitro</i> study.\",\"authors\":\"Mohammed Assayed Mousa, Hasna Alshubrmi, Rakhi Issrani, Bader Kureyem Alzarea\",\"doi\":\"10.4047/jap.2024.16.6.336\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study assessed the microgap width and adhesion of three bacterial species in four dental implants with different interlocks under four screwing torques.</p><p><strong>Materials and methods: </strong>Ten samples of four implant systems with various interlockings, including full-hexagonal (FHI), cylindrical-conical trilobe-index (TLI), Morse-taper with octagon terminal index (OI), and hexagonal interlock (slip-fit) (HI-SF), were used. The abutments were screwed to the fixtures under torques of 10, 20, 30, and 40 Ncm. The microgap between the abutment and the platform was assessed using a Scanning Electron Microscope (SEM). The leakage of 3 bacteria, including Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa, was evaluated under 30 Ncm torque.</p><p><strong>Results: </strong>The TLI system showed the widest gap under all torques compared to others. There was no significance among all systems under different screwing torques. Regarding the leakage, there was no adherence to <i>E. coli</i> and <i>S. aureus</i> and 36.4% of <i>Ps. aeruginosa</i> to the HI-SF, followed by the OI system. The FHI and TLI systems showed the highest bacterial adherence.</p><p><strong>Conclusion: </strong>Even with low torque, the studied systems showed gap widths narrower than acceptable width. Implant systems with FHI and OI demonstrated misfits of less than 2 µm upon 10 Ncm and less than 1 µm when the torque increases, giving them priority to be used in areas with poor bone quality. The HI-SF demonstrated a high ability to resist the adherence to <i>E. coli</i> and <i>S. aureus</i>, followed by OI. However, <i>Ps. aeruginosa</i> demonstrated a high ability to adhere to all systems.</p>\",\"PeriodicalId\":51291,\"journal\":{\"name\":\"Journal of Advanced Prosthodontics\",\"volume\":\"16 6\",\"pages\":\"336-347\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11711449/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4047/jap.2024.16.6.336\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4047/jap.2024.16.6.336","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/19 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究4种不同连锁牙种植体在4种螺纹扭矩下的微间隙宽度和3种细菌的粘附力。材料和方法:采用四种不同互锁的种植体系统,包括全六边形(FHI)、圆柱-圆锥三叶指数(TLI)、带有八边形终端指数的莫尔斯锥(OI)和六边形互锁(滑合)(HI-SF),共10个样品。在10、20、30和40 Ncm的扭矩下,将基台拧到固定装置上。利用扫描电子显微镜(SEM)评估基台与平台之间的微间隙。在30 Ncm扭矩下评估金黄色葡萄球菌、大肠杆菌、铜绿假单胞菌3种细菌的渗漏情况。结果:与其他系统相比,TLI系统在所有扭矩下的间隙最大。不同旋紧力矩下各系统间无显著性差异。对于渗漏,大肠杆菌和金黄色葡萄球菌没有粘附,铜绿假单胞菌对HI-SF的粘附率为36.4%,其次是OI系统。FHI和TLI系统显示出最高的细菌粘附。结论:即使在低扭矩的情况下,所研究的系统的间隙宽度也比可接受的宽度窄。具有FHI和OI的植入体系统在10 Ncm时显示不匹配小于2 μ m,当扭矩增加时小于1 μ m,这使得它们优先用于骨质量差的区域。HI-SF表现出对大肠杆菌和金黄色葡萄球菌粘附的高抵抗能力,其次是OI。然而,铜绿假单胞菌表现出对所有系统的高粘附能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluating the microgap and sealing capability in four implant systems with different interlockings under different tightening torques: an in-vitro study.

Purpose: This study assessed the microgap width and adhesion of three bacterial species in four dental implants with different interlocks under four screwing torques.

Materials and methods: Ten samples of four implant systems with various interlockings, including full-hexagonal (FHI), cylindrical-conical trilobe-index (TLI), Morse-taper with octagon terminal index (OI), and hexagonal interlock (slip-fit) (HI-SF), were used. The abutments were screwed to the fixtures under torques of 10, 20, 30, and 40 Ncm. The microgap between the abutment and the platform was assessed using a Scanning Electron Microscope (SEM). The leakage of 3 bacteria, including Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa, was evaluated under 30 Ncm torque.

Results: The TLI system showed the widest gap under all torques compared to others. There was no significance among all systems under different screwing torques. Regarding the leakage, there was no adherence to E. coli and S. aureus and 36.4% of Ps. aeruginosa to the HI-SF, followed by the OI system. The FHI and TLI systems showed the highest bacterial adherence.

Conclusion: Even with low torque, the studied systems showed gap widths narrower than acceptable width. Implant systems with FHI and OI demonstrated misfits of less than 2 µm upon 10 Ncm and less than 1 µm when the torque increases, giving them priority to be used in areas with poor bone quality. The HI-SF demonstrated a high ability to resist the adherence to E. coli and S. aureus, followed by OI. However, Ps. aeruginosa demonstrated a high ability to adhere to all systems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Advanced Prosthodontics
Journal of Advanced Prosthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.70
自引率
3.80%
发文量
25
期刊介绍: This journal aims to convey scientific and clinical progress in the field of prosthodontics and its related areas to many dental communities concerned with esthetic and functional restorations, occlusion, implants, prostheses, and biomaterials related to prosthodontics. This journal publishes • Original research data of high scientific merit in the field of diagnosis, function, esthetics and stomatognathic physiology related to prosthodontic rehabilitation, physiology and mechanics of occlusion, mechanical and biologic aspects of prosthodontic materials including dental implants. • Review articles by experts on controversies and new developments in prosthodontics. • Case reports if they provide or document new fundamental knowledge.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信