磁性分子印迹聚合物联用UPLC-MS/MS同时检测人血浆中19种类固醇激素

IF 4 2区 化学 Q1 BIOCHEMICAL RESEARCH METHODS
Chunyi Yu , Xujing Kong , Wenting Li , Boyu Li , Baorong Chen , Mengyao Gao , Susu Cai , Yun Wei
{"title":"磁性分子印迹聚合物联用UPLC-MS/MS同时检测人血浆中19种类固醇激素","authors":"Chunyi Yu ,&nbsp;Xujing Kong ,&nbsp;Wenting Li ,&nbsp;Boyu Li ,&nbsp;Baorong Chen ,&nbsp;Mengyao Gao ,&nbsp;Susu Cai ,&nbsp;Yun Wei","doi":"10.1016/j.chroma.2025.465655","DOIUrl":null,"url":null,"abstract":"<div><div>Steroid hormones constitute a group of hormones with molecular weights ranging from 200 to 400 daltons, characterized by their highly similar chemical structures. Each hormone within this group holds significant value for the diagnosis of various diseases. Accurate clinical measurement of the levels of each hormone is crucial for the diagnosis in clinical settings. Due to the wide variety and different properties of steroid hormones in organisms, sample pretreatment is the rate-limiting step for analysis and detection. In this paper, magnetic molecule-imprinting polymers (MMIPs) were prepared by surface imprinting on silicon coated magnetic spheres, and a detection method of MMIPs-combined with liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for 19 steroid hormones in plasma was developed and verified. Fourier transform infrared spectroscopy, field emission scanning electron microscopy and transmission electron microscopy were used to confirm the formation of MMIPs materials, and the conditions of material synthesis and pretreatment of steroid hormones from plasma were optimized. The detection method was evaluated by using linearity, LOD and LOQ, precision, accuracy and matrix effect. The linearity of 19 steroid hormones was good, and the linear correlation coefficient was greater than 0.995. The coefficients of variation were 2.1–9.8 % and 1.1–9.7 % for intra-day and inter-day, respectively, and the recoveries were 83.6 %-118.2 % at low concentration, and the recoveries of medium and high concentrations were 94.6 %-113.8 % and 89.5 %-113.6 %, respectively. The coefficient of variation of Relative matrix effect of 19 steroid hormones measured in different batches of plasma was 2.1–5.4 % after isotope internal standard correction, which eliminated the influence of matrix effect.</div></div>","PeriodicalId":347,"journal":{"name":"Journal of Chromatography A","volume":"1742 ","pages":"Article 465655"},"PeriodicalIF":4.0000,"publicationDate":"2025-01-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Magnetic molecularly imprinted polymers coupled with UPLC-MS/MS for simultaneous detection of 19 steroid hormones in human plasma\",\"authors\":\"Chunyi Yu ,&nbsp;Xujing Kong ,&nbsp;Wenting Li ,&nbsp;Boyu Li ,&nbsp;Baorong Chen ,&nbsp;Mengyao Gao ,&nbsp;Susu Cai ,&nbsp;Yun Wei\",\"doi\":\"10.1016/j.chroma.2025.465655\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Steroid hormones constitute a group of hormones with molecular weights ranging from 200 to 400 daltons, characterized by their highly similar chemical structures. Each hormone within this group holds significant value for the diagnosis of various diseases. Accurate clinical measurement of the levels of each hormone is crucial for the diagnosis in clinical settings. Due to the wide variety and different properties of steroid hormones in organisms, sample pretreatment is the rate-limiting step for analysis and detection. In this paper, magnetic molecule-imprinting polymers (MMIPs) were prepared by surface imprinting on silicon coated magnetic spheres, and a detection method of MMIPs-combined with liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for 19 steroid hormones in plasma was developed and verified. Fourier transform infrared spectroscopy, field emission scanning electron microscopy and transmission electron microscopy were used to confirm the formation of MMIPs materials, and the conditions of material synthesis and pretreatment of steroid hormones from plasma were optimized. The detection method was evaluated by using linearity, LOD and LOQ, precision, accuracy and matrix effect. The linearity of 19 steroid hormones was good, and the linear correlation coefficient was greater than 0.995. The coefficients of variation were 2.1–9.8 % and 1.1–9.7 % for intra-day and inter-day, respectively, and the recoveries were 83.6 %-118.2 % at low concentration, and the recoveries of medium and high concentrations were 94.6 %-113.8 % and 89.5 %-113.6 %, respectively. The coefficient of variation of Relative matrix effect of 19 steroid hormones measured in different batches of plasma was 2.1–5.4 % after isotope internal standard correction, which eliminated the influence of matrix effect.</div></div>\",\"PeriodicalId\":347,\"journal\":{\"name\":\"Journal of Chromatography A\",\"volume\":\"1742 \",\"pages\":\"Article 465655\"},\"PeriodicalIF\":4.0000,\"publicationDate\":\"2025-01-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Chromatography A\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0021967325000044\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography A","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021967325000044","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

类固醇激素是一组分子量在200 - 400道尔顿之间的激素,其化学结构高度相似。该组中的每一种激素对各种疾病的诊断都具有重要的价值。准确的临床测量每一种激素的水平对于临床诊断是至关重要的。由于生物体内类固醇激素种类繁多,性质各异,样品预处理是分析和检测的限速步骤。本文通过在硅包覆磁球表面印迹制备磁性分子印迹聚合物(MMIPs),建立了MMIPs-液相色谱-串联质谱(UPLC-MS/MS)联合检测血浆中19种类固醇激素的方法并进行了验证。利用傅里叶变换红外光谱、场发射扫描电镜和透射电镜证实了MMIPs材料的形成,并优化了材料合成和血浆中类固醇激素预处理的条件。从线性度、LOD和LOQ、精密度、准确度和矩阵效应等方面对检测方法进行评价。19种类固醇激素的线性关系良好,线性相关系数均大于0.995。日内、日间变异系数分别为2.1 ~ 9.8%和1.1 ~ 9.7%,低浓度时加样回收率为83.6% ~ 118.2%,中、高浓度时加样回收率分别为94.6% ~ 113.8%和89.5% ~ 113.6%。不同批次血浆中19种类固醇激素经同位素内标校正后的相对基质效应变异系数为2.1 ~ 5.4%,消除了基质效应的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Magnetic molecularly imprinted polymers coupled with UPLC-MS/MS for simultaneous detection of 19 steroid hormones in human plasma
Steroid hormones constitute a group of hormones with molecular weights ranging from 200 to 400 daltons, characterized by their highly similar chemical structures. Each hormone within this group holds significant value for the diagnosis of various diseases. Accurate clinical measurement of the levels of each hormone is crucial for the diagnosis in clinical settings. Due to the wide variety and different properties of steroid hormones in organisms, sample pretreatment is the rate-limiting step for analysis and detection. In this paper, magnetic molecule-imprinting polymers (MMIPs) were prepared by surface imprinting on silicon coated magnetic spheres, and a detection method of MMIPs-combined with liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for 19 steroid hormones in plasma was developed and verified. Fourier transform infrared spectroscopy, field emission scanning electron microscopy and transmission electron microscopy were used to confirm the formation of MMIPs materials, and the conditions of material synthesis and pretreatment of steroid hormones from plasma were optimized. The detection method was evaluated by using linearity, LOD and LOQ, precision, accuracy and matrix effect. The linearity of 19 steroid hormones was good, and the linear correlation coefficient was greater than 0.995. The coefficients of variation were 2.1–9.8 % and 1.1–9.7 % for intra-day and inter-day, respectively, and the recoveries were 83.6 %-118.2 % at low concentration, and the recoveries of medium and high concentrations were 94.6 %-113.8 % and 89.5 %-113.6 %, respectively. The coefficient of variation of Relative matrix effect of 19 steroid hormones measured in different batches of plasma was 2.1–5.4 % after isotope internal standard correction, which eliminated the influence of matrix effect.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Chromatography A
Journal of Chromatography A 化学-分析化学
CiteScore
7.90
自引率
14.60%
发文量
742
审稿时长
45 days
期刊介绍: The Journal of Chromatography A provides a forum for the publication of original research and critical reviews on all aspects of fundamental and applied separation science. The scope of the journal includes chromatography and related techniques, electromigration techniques (e.g. electrophoresis, electrochromatography), hyphenated and other multi-dimensional techniques, sample preparation, and detection methods such as mass spectrometry. Contributions consist mainly of research papers dealing with the theory of separation methods, instrumental developments and analytical and preparative applications of general interest.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信