9482例患者的倾向匹配分析:在机器人辅助手术中,Palmer、脐静脉针和开放入路技术的比较结果。

IF 2.2 3区 医学 Q2 SURGERY
Ahmed Eraky, Mohammed Almoflihi, Modassar Awan, Mohammad Jaabou, Miriam Campistol, Neeraja Tillu, Manish Kumar Choudhary, Arjun Venkatesh, Kaushik P Kolanukuduru, Zachary Dovey, Osama Zaytoun, Maurizio Buscarini
{"title":"9482例患者的倾向匹配分析:在机器人辅助手术中,Palmer、脐静脉针和开放入路技术的比较结果。","authors":"Ahmed Eraky, Mohammed Almoflihi, Modassar Awan, Mohammad Jaabou, Miriam Campistol, Neeraja Tillu, Manish Kumar Choudhary, Arjun Venkatesh, Kaushik P Kolanukuduru, Zachary Dovey, Osama Zaytoun, Maurizio Buscarini","doi":"10.1007/s11701-024-02208-x","DOIUrl":null,"url":null,"abstract":"<p><p>Robotic-assisted surgery offers several advantages over traditional methods, such as reduced blood loss and fewer complications. Establishing pneumoperitoneum is a critical step, with two primary techniques: the Veress needle (closed) and the Hasson (open) technique. Despite extensive studies in laparoscopic surgery, limited data exist regarding their use in robotic surgery. This study compares complication rates and predictors between Palmer, umbilical Veress needle, and open Hasson techniques in robotic surgery. In this retrospective cohort study of 9482 patients undergoing robotic surgery, we compared palmer, umbilical Veress needle, and Open Hasson techniques using propensity score matching. Primary outcomes were complication rates classified by the Clavien-Dindo system. We used logistic regression to analyze predictors of complications, such as needle attempts and adhesions. One thousand sixteen patients were matched between Palmer and umbilical groups and 310 between Veress needle and open groups. Umbilical insertion was associated with more complications than Palmer (OR 2.14, p = 0.033). Patients requiring more than four needle attempts had higher complication rates (OR 15.43, p = 0.002). Severe adhesions significantly increased complications. After adjustment, the choice of entry method was not independently associated with complications. Surgical entry complications in robotic-assisted surgery are more influenced by needle attempts and adhesions than by the choice of entry technique. Tailoring surgical plans based on patient characteristics and minimizing needle attempts can improve outcomes, underscoring the importance of individualized approaches over standardized methods.</p>","PeriodicalId":47616,"journal":{"name":"Journal of Robotic Surgery","volume":"19 1","pages":"48"},"PeriodicalIF":2.2000,"publicationDate":"2025-01-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative outcomes of Palmer, Umbilical Veress needle, and open entry techniques in robotic-assisted surgery: a propensity-matched analysis of 9482 patients.\",\"authors\":\"Ahmed Eraky, Mohammed Almoflihi, Modassar Awan, Mohammad Jaabou, Miriam Campistol, Neeraja Tillu, Manish Kumar Choudhary, Arjun Venkatesh, Kaushik P Kolanukuduru, Zachary Dovey, Osama Zaytoun, Maurizio Buscarini\",\"doi\":\"10.1007/s11701-024-02208-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Robotic-assisted surgery offers several advantages over traditional methods, such as reduced blood loss and fewer complications. Establishing pneumoperitoneum is a critical step, with two primary techniques: the Veress needle (closed) and the Hasson (open) technique. Despite extensive studies in laparoscopic surgery, limited data exist regarding their use in robotic surgery. This study compares complication rates and predictors between Palmer, umbilical Veress needle, and open Hasson techniques in robotic surgery. In this retrospective cohort study of 9482 patients undergoing robotic surgery, we compared palmer, umbilical Veress needle, and Open Hasson techniques using propensity score matching. Primary outcomes were complication rates classified by the Clavien-Dindo system. We used logistic regression to analyze predictors of complications, such as needle attempts and adhesions. One thousand sixteen patients were matched between Palmer and umbilical groups and 310 between Veress needle and open groups. Umbilical insertion was associated with more complications than Palmer (OR 2.14, p = 0.033). Patients requiring more than four needle attempts had higher complication rates (OR 15.43, p = 0.002). Severe adhesions significantly increased complications. After adjustment, the choice of entry method was not independently associated with complications. Surgical entry complications in robotic-assisted surgery are more influenced by needle attempts and adhesions than by the choice of entry technique. Tailoring surgical plans based on patient characteristics and minimizing needle attempts can improve outcomes, underscoring the importance of individualized approaches over standardized methods.</p>\",\"PeriodicalId\":47616,\"journal\":{\"name\":\"Journal of Robotic Surgery\",\"volume\":\"19 1\",\"pages\":\"48\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2025-01-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Robotic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11701-024-02208-x\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Robotic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11701-024-02208-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

与传统方法相比,机器人辅助手术有几个优点,比如减少失血和减少并发症。建立气腹是关键的一步,有两种主要技术:Veress针(闭式)和Hasson针(开放式)技术。尽管对腹腔镜手术进行了广泛的研究,但关于腹腔镜在机器人手术中的应用的数据有限。本研究比较了Palmer、脐Veress针和开放式Hasson技术在机器人手术中的并发症发生率和预测因素。在这项9482例接受机器人手术的患者的回顾性队列研究中,我们使用倾向评分匹配比较了帕尔默、脐带Veress针和Open Hasson技术。主要结局是并发症发生率按Clavien-Dindo系统分类。我们使用逻辑回归分析并发症的预测因素,如针头尝试和粘连。帕尔默组和脐带组有1616名患者匹配,韦雷斯针组和开放组有310名患者匹配。脐带置入比帕尔默置入并发症更多(OR 2.14, p = 0.033)。需要4次以上针头尝试的患者并发症发生率更高(OR 15.43, p = 0.002)。严重的粘连明显增加并发症。调整后,入路选择与并发症无独立相关性。在机器人辅助手术中,手术入路并发症更多的是受针头尝试和粘连的影响,而不是受入路技术选择的影响。根据患者的特点量身定制手术计划,尽量减少针头尝试,可以改善结果,强调个性化方法比标准化方法的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative outcomes of Palmer, Umbilical Veress needle, and open entry techniques in robotic-assisted surgery: a propensity-matched analysis of 9482 patients.

Robotic-assisted surgery offers several advantages over traditional methods, such as reduced blood loss and fewer complications. Establishing pneumoperitoneum is a critical step, with two primary techniques: the Veress needle (closed) and the Hasson (open) technique. Despite extensive studies in laparoscopic surgery, limited data exist regarding their use in robotic surgery. This study compares complication rates and predictors between Palmer, umbilical Veress needle, and open Hasson techniques in robotic surgery. In this retrospective cohort study of 9482 patients undergoing robotic surgery, we compared palmer, umbilical Veress needle, and Open Hasson techniques using propensity score matching. Primary outcomes were complication rates classified by the Clavien-Dindo system. We used logistic regression to analyze predictors of complications, such as needle attempts and adhesions. One thousand sixteen patients were matched between Palmer and umbilical groups and 310 between Veress needle and open groups. Umbilical insertion was associated with more complications than Palmer (OR 2.14, p = 0.033). Patients requiring more than four needle attempts had higher complication rates (OR 15.43, p = 0.002). Severe adhesions significantly increased complications. After adjustment, the choice of entry method was not independently associated with complications. Surgical entry complications in robotic-assisted surgery are more influenced by needle attempts and adhesions than by the choice of entry technique. Tailoring surgical plans based on patient characteristics and minimizing needle attempts can improve outcomes, underscoring the importance of individualized approaches over standardized methods.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.20
自引率
8.70%
发文量
145
期刊介绍: The aim of the Journal of Robotic Surgery is to become the leading worldwide journal for publication of articles related to robotic surgery, encompassing surgical simulation and integrated imaging techniques. The journal provides a centralized, focused resource for physicians wishing to publish their experience or those wishing to avail themselves of the most up-to-date findings.The journal reports on advance in a wide range of surgical specialties including adult and pediatric urology, general surgery, cardiac surgery, gynecology, ENT, orthopedics and neurosurgery.The use of robotics in surgery is broad-based and will undoubtedly expand over the next decade as new technical innovations and techniques increase the applicability of its use. The journal intends to capture this trend as it develops.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信