{"title":"增强现实技术在第一阶段骶神经调节中精确穿刺的应用。","authors":"Haoyu Yuan, Yuansong Xiao, Xiaoyu Lin, Lei Zhang, Chenglin Yang, Zhengfei Hu, Yue Yang, Peixian Wu","doi":"10.5213/inj.2448330.165","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Precise electrode placement is crucial for the success of sacral neuromodulation (SNM). The aim of this study was to explore a more accurate and convenient method for positioning punctures during the first stage of SNM.</p><p><strong>Methods: </strong>This retrospective study compared preoperative baseline values, intraoperative indicators, postoperative scores, and other clinical data from 130 patients who underwent SNM electrode implantation at our department between 2018 and 2023. The patients were divided into an experimental group and a control group to assess the advantages and feasibility of augmented reality (AR)-guided sacral nerve electrode implantation.</p><p><strong>Results: </strong>The experimental group experienced fewer intraoperative puncture attempts and achieved more accurate AR-guided localization punctures. Additionally, there were more responsive electrode contact points (2.74±0.51 vs. 2.46±0.74) and a lower initial voltage postimplantation (1.09±0.39 V vs. 1.69±0.43 V). The number of intraoperative x-ray fluoroscopies was significantly lower in the experimental group than in the control group (5.94±1.46 vs. 9.22±1.93), leading to a shorter overall operation time (61.32±11.27 minutes vs. 83.49±15.84 minutes). Furthermore, there was no need for additional local anesthetic drugs during the surgery in the experimental group. Comparative observations revealed no significant differences in intraoperative blood loss or the sacral hole location for electrode implantation between the 2 groups. Although the incidence of wound infection and the rate of permanent implantation in stage 2 were similar in both groups, the pain score on the first day postoperation was significantly lower in the experimental group than in the control group (2.62±0.697 vs. 2.83±0.816).</p><p><strong>Conclusion: </strong>AR-guided sacral nerve modulation implantation can reduce both the number of punctures and the duration of the operation while ensuring safety and effectiveness. This technique can enhance the contact points of the response electrode, effectively lower the initial response voltage, and stabilize the electrode.</p>","PeriodicalId":14466,"journal":{"name":"International Neurourology Journal","volume":"28 4","pages":"302-311"},"PeriodicalIF":1.8000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11710959/pdf/","citationCount":"0","resultStr":"{\"title\":\"Application of Augmented Reality for Accurate Punctures During Stage 1 Sacral Neuromodulation.\",\"authors\":\"Haoyu Yuan, Yuansong Xiao, Xiaoyu Lin, Lei Zhang, Chenglin Yang, Zhengfei Hu, Yue Yang, Peixian Wu\",\"doi\":\"10.5213/inj.2448330.165\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Precise electrode placement is crucial for the success of sacral neuromodulation (SNM). The aim of this study was to explore a more accurate and convenient method for positioning punctures during the first stage of SNM.</p><p><strong>Methods: </strong>This retrospective study compared preoperative baseline values, intraoperative indicators, postoperative scores, and other clinical data from 130 patients who underwent SNM electrode implantation at our department between 2018 and 2023. The patients were divided into an experimental group and a control group to assess the advantages and feasibility of augmented reality (AR)-guided sacral nerve electrode implantation.</p><p><strong>Results: </strong>The experimental group experienced fewer intraoperative puncture attempts and achieved more accurate AR-guided localization punctures. Additionally, there were more responsive electrode contact points (2.74±0.51 vs. 2.46±0.74) and a lower initial voltage postimplantation (1.09±0.39 V vs. 1.69±0.43 V). The number of intraoperative x-ray fluoroscopies was significantly lower in the experimental group than in the control group (5.94±1.46 vs. 9.22±1.93), leading to a shorter overall operation time (61.32±11.27 minutes vs. 83.49±15.84 minutes). Furthermore, there was no need for additional local anesthetic drugs during the surgery in the experimental group. Comparative observations revealed no significant differences in intraoperative blood loss or the sacral hole location for electrode implantation between the 2 groups. Although the incidence of wound infection and the rate of permanent implantation in stage 2 were similar in both groups, the pain score on the first day postoperation was significantly lower in the experimental group than in the control group (2.62±0.697 vs. 2.83±0.816).</p><p><strong>Conclusion: </strong>AR-guided sacral nerve modulation implantation can reduce both the number of punctures and the duration of the operation while ensuring safety and effectiveness. This technique can enhance the contact points of the response electrode, effectively lower the initial response voltage, and stabilize the electrode.</p>\",\"PeriodicalId\":14466,\"journal\":{\"name\":\"International Neurourology Journal\",\"volume\":\"28 4\",\"pages\":\"302-311\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11710959/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Neurourology Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5213/inj.2448330.165\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Neurourology Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5213/inj.2448330.165","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0
摘要
目的:精确的电极放置是骶神经调节(SNM)成功的关键。本研究旨在探索一种更准确、更方便的SNM第一阶段穿刺定位方法。方法:本回顾性研究比较了2018年至2023年在我科接受SNM电极植入的130例患者的术前基线值、术中指标、术后评分等临床资料。将患者分为实验组和对照组,评估增强现实(AR)引导下骶神经电极植入的优势和可行性。结果:实验组术中穿刺次数较少,ar引导定位穿刺更准确。此外,实验组有更多的电极接触点(2.74±0.51 vs. 2.46±0.74)和更低的植入后初始电压(1.09±0.39 V vs. 1.69±0.43 V),术中x线透视次数明显少于对照组(5.94±1.46 vs. 9.22±1.93),导致总手术时间缩短(61.32±11.27分钟vs. 83.49±15.84分钟)。此外,实验组在手术过程中不需要额外的局麻药物。对比观察,两组患者术中出血量及电极植入骶骨孔位置无显著差异。两组术后创面感染发生率及二期永久植入率相近,但术后第1天疼痛评分实验组明显低于对照组(2.62±0.697∶2.83±0.816)。结论:ar引导下骶神经调节植入术在保证安全性和有效性的同时,减少了穿刺次数和手术时间。该技术可以增强响应电极的接触点,有效降低初始响应电压,稳定电极。
Application of Augmented Reality for Accurate Punctures During Stage 1 Sacral Neuromodulation.
Purpose: Precise electrode placement is crucial for the success of sacral neuromodulation (SNM). The aim of this study was to explore a more accurate and convenient method for positioning punctures during the first stage of SNM.
Methods: This retrospective study compared preoperative baseline values, intraoperative indicators, postoperative scores, and other clinical data from 130 patients who underwent SNM electrode implantation at our department between 2018 and 2023. The patients were divided into an experimental group and a control group to assess the advantages and feasibility of augmented reality (AR)-guided sacral nerve electrode implantation.
Results: The experimental group experienced fewer intraoperative puncture attempts and achieved more accurate AR-guided localization punctures. Additionally, there were more responsive electrode contact points (2.74±0.51 vs. 2.46±0.74) and a lower initial voltage postimplantation (1.09±0.39 V vs. 1.69±0.43 V). The number of intraoperative x-ray fluoroscopies was significantly lower in the experimental group than in the control group (5.94±1.46 vs. 9.22±1.93), leading to a shorter overall operation time (61.32±11.27 minutes vs. 83.49±15.84 minutes). Furthermore, there was no need for additional local anesthetic drugs during the surgery in the experimental group. Comparative observations revealed no significant differences in intraoperative blood loss or the sacral hole location for electrode implantation between the 2 groups. Although the incidence of wound infection and the rate of permanent implantation in stage 2 were similar in both groups, the pain score on the first day postoperation was significantly lower in the experimental group than in the control group (2.62±0.697 vs. 2.83±0.816).
Conclusion: AR-guided sacral nerve modulation implantation can reduce both the number of punctures and the duration of the operation while ensuring safety and effectiveness. This technique can enhance the contact points of the response electrode, effectively lower the initial response voltage, and stabilize the electrode.
期刊介绍:
The International Neurourology Journal (Int Neurourol J, INJ) is a quarterly international journal that publishes high-quality research papers that provide the most significant and promising achievements in the fields of clinical neurourology and fundamental science. Specifically, fundamental science includes the most influential research papers from all fields of science and technology, revolutionizing what physicians and researchers practicing the art of neurourology worldwide know. Thus, we welcome valuable basic research articles to introduce cutting-edge translational research of fundamental sciences to clinical neurourology. In the editorials, urologists will present their perspectives on these articles. The original mission statement of the INJ was published on October 12, 1997.
INJ provides authors a fast review of their work and makes a decision in an average of three to four weeks of receiving submissions. If accepted, articles are posted online in fully citable form. Supplementary issues will be published interim to quarterlies, as necessary, to fully allow berth to accept and publish relevant articles.