{"title":"tirobot辅助与徒手放置股骨颈系统治疗股骨颈骨折:系统回顾和荟萃分析","authors":"Yupei Dai, Kaiyong Wang, Guohang Shen, Yang Chen, Anneng Hu, Qunhua Jin","doi":"10.1007/s11701-024-02204-1","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study is to assess the safety and effectiveness of TiRobot-assisted treatment for femoral neck fractures, in comparison to traditional freehand treatment methods. Throughout the research process, we conducted an extensive literature search across numerous databases, including PubMed, EMBASE, Cochrane Library, Web of Science, China National Knowledge Infrastructure (CNKI), CQVIP, and Wanfang. Based on the literature screening criteria, we selected six studies, encompassing 358 cases of femoral neck fracture patients, for this meta-analysis. The study evaluated the effectiveness of TiRobot-assisted versus freehand placement of the Femoral Neck System (FNS). The results indicate that the TiRobot-assisted group demonstrated significant advantages in several surgical parameters. Specifically, the robot-assisted group showed superior outcomes regarding the frequency of guide pin insertion, frequency of X-ray fluoroscopy, operative time, invasive fixation time, intraoperative blood loss and incision length (MD < 0, p < 0.05). Furthermore, there was a significant difference in the Harris score, between the TiRobot-assisted group and the traditional freehand group (MD > 0, p < 0.05). However, the two groups had no significant differences concerning postoperative complications, fracture healing time, and fracture healing rate (p > 0.05). In conclusion, the comprehensive analysis suggests that the TiRobot-assisted technique has distinct advantages over the traditional freehand technique in treating femoral neck fractures. TiRobot-assisted technology, owing to its enhanced safety and efficacy, minimizes surgical trauma and expedites postoperative recovery.</p>","PeriodicalId":47616,"journal":{"name":"Journal of Robotic Surgery","volume":"19 1","pages":"43"},"PeriodicalIF":2.2000,"publicationDate":"2025-01-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"TiRobot-assisted versus freehand femoral neck system placement in the treatment of femoral neck fractures: a systematic review and meta-analysis.\",\"authors\":\"Yupei Dai, Kaiyong Wang, Guohang Shen, Yang Chen, Anneng Hu, Qunhua Jin\",\"doi\":\"10.1007/s11701-024-02204-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this study is to assess the safety and effectiveness of TiRobot-assisted treatment for femoral neck fractures, in comparison to traditional freehand treatment methods. Throughout the research process, we conducted an extensive literature search across numerous databases, including PubMed, EMBASE, Cochrane Library, Web of Science, China National Knowledge Infrastructure (CNKI), CQVIP, and Wanfang. Based on the literature screening criteria, we selected six studies, encompassing 358 cases of femoral neck fracture patients, for this meta-analysis. The study evaluated the effectiveness of TiRobot-assisted versus freehand placement of the Femoral Neck System (FNS). The results indicate that the TiRobot-assisted group demonstrated significant advantages in several surgical parameters. Specifically, the robot-assisted group showed superior outcomes regarding the frequency of guide pin insertion, frequency of X-ray fluoroscopy, operative time, invasive fixation time, intraoperative blood loss and incision length (MD < 0, p < 0.05). Furthermore, there was a significant difference in the Harris score, between the TiRobot-assisted group and the traditional freehand group (MD > 0, p < 0.05). However, the two groups had no significant differences concerning postoperative complications, fracture healing time, and fracture healing rate (p > 0.05). In conclusion, the comprehensive analysis suggests that the TiRobot-assisted technique has distinct advantages over the traditional freehand technique in treating femoral neck fractures. TiRobot-assisted technology, owing to its enhanced safety and efficacy, minimizes surgical trauma and expedites postoperative recovery.</p>\",\"PeriodicalId\":47616,\"journal\":{\"name\":\"Journal of Robotic Surgery\",\"volume\":\"19 1\",\"pages\":\"43\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2025-01-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Robotic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11701-024-02204-1\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Robotic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11701-024-02204-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
摘要
本研究的目的是评估tirobot辅助治疗股骨颈骨折的安全性和有效性,并与传统的徒手治疗方法进行比较。在整个研究过程中,我们在PubMed、EMBASE、Cochrane Library、Web of Science、CNKI、CQVIP和万方等多个数据库中进行了广泛的文献检索。根据文献筛选标准,我们选择了6项研究,包括358例股骨颈骨折患者,进行meta分析。该研究评估了tirobot辅助与徒手放置股骨颈系统(FNS)的有效性。结果表明,tirobot辅助组在几个手术参数上表现出显著的优势。其中,机器人辅助组在导针插入次数、x线透视次数、手术时间、有创固定时间、术中出血量、切口长度等方面均优于机器人辅助组(MD 0, p 0.05)。综上所述,综合分析表明,tirobot辅助技术在治疗股骨颈骨折方面比传统的徒手技术具有明显的优势。tirobot辅助技术,由于其增强的安全性和有效性,最大限度地减少手术创伤,加快术后恢复。
TiRobot-assisted versus freehand femoral neck system placement in the treatment of femoral neck fractures: a systematic review and meta-analysis.
The purpose of this study is to assess the safety and effectiveness of TiRobot-assisted treatment for femoral neck fractures, in comparison to traditional freehand treatment methods. Throughout the research process, we conducted an extensive literature search across numerous databases, including PubMed, EMBASE, Cochrane Library, Web of Science, China National Knowledge Infrastructure (CNKI), CQVIP, and Wanfang. Based on the literature screening criteria, we selected six studies, encompassing 358 cases of femoral neck fracture patients, for this meta-analysis. The study evaluated the effectiveness of TiRobot-assisted versus freehand placement of the Femoral Neck System (FNS). The results indicate that the TiRobot-assisted group demonstrated significant advantages in several surgical parameters. Specifically, the robot-assisted group showed superior outcomes regarding the frequency of guide pin insertion, frequency of X-ray fluoroscopy, operative time, invasive fixation time, intraoperative blood loss and incision length (MD < 0, p < 0.05). Furthermore, there was a significant difference in the Harris score, between the TiRobot-assisted group and the traditional freehand group (MD > 0, p < 0.05). However, the two groups had no significant differences concerning postoperative complications, fracture healing time, and fracture healing rate (p > 0.05). In conclusion, the comprehensive analysis suggests that the TiRobot-assisted technique has distinct advantages over the traditional freehand technique in treating femoral neck fractures. TiRobot-assisted technology, owing to its enhanced safety and efficacy, minimizes surgical trauma and expedites postoperative recovery.
期刊介绍:
The aim of the Journal of Robotic Surgery is to become the leading worldwide journal for publication of articles related to robotic surgery, encompassing surgical simulation and integrated imaging techniques. The journal provides a centralized, focused resource for physicians wishing to publish their experience or those wishing to avail themselves of the most up-to-date findings.The journal reports on advance in a wide range of surgical specialties including adult and pediatric urology, general surgery, cardiac surgery, gynecology, ENT, orthopedics and neurosurgery.The use of robotics in surgery is broad-based and will undoubtedly expand over the next decade as new technical innovations and techniques increase the applicability of its use. The journal intends to capture this trend as it develops.