pH值对固定矫治器在人工唾液中镍离子释放的影响。

Q2 Dentistry
Journal of Orthodontic Science Pub Date : 2024-11-25 eCollection Date: 2024-01-01 DOI:10.4103/jos.jos_8_24
Youssouf Ouédraogo, Abdoul Karim Sakira, Moussa Ouédraogo, Issa Tapsoba, Tarcissus Konsem, Jean Bertin Beugré
{"title":"pH值对固定矫治器在人工唾液中镍离子释放的影响。","authors":"Youssouf Ouédraogo, Abdoul Karim Sakira, Moussa Ouédraogo, Issa Tapsoba, Tarcissus Konsem, Jean Bertin Beugré","doi":"10.4103/jos.jos_8_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The aim of this study was to make a laboratory assessment of pH influence on the kinetics of the release of nickel ions in artificial saliva.</p><p><strong>Methods and material: </strong>In this study, 15 basic orthodontic appliances are immersed in 15 polyethylene tubes each containing 40 ml of artificial saliva. Tubes were divided into three sub-groups of 5 tubes depending on the pH: pH 5, pH 7 and pH 8. The release of nickel ions was measured using atomic absorption spectrometry in a sample of 5 ml of artificial saliva taken one hour, four hours and one hundred and sixty-eight hours after immersion in a water bath at 37°.</p><p><strong>Statistical analysis used: </strong>Significance threshold <i>P</i> was set at 0.05. A Student T test and the 2-way Anova test (with a Bonferoni post-test) were used respectively to compare the means.</p><p><strong>Results: </strong>The neutral pH causes a low release of nickel ions. The release kinetics of nickel ions is minimal for neutral pH, it increases when pH varies. After one hour of immersion, the nickel released did not reach the spectrometer quantification threshold as for neutral and acid pH. The alkaline pH causes an average release of nickel ions from the beginning without kinetic variation. As time passes (T3), the acidic pH causes more nickel ions release through a succession of oxidation-reduction reactions. After 168 hours, the average mass of nickel released is 0.30 µg for pH 7, 1.35 µg for pH 8 and up to 2.85 µg for pH 5.</p><p><strong>Conclusions: </strong>Quantities released did not reach nickel toxicity threshold in humans. Orthodontists must consider the potential risk of hypersensitivity due to nickel in fixed orthodontic appliances.</p>","PeriodicalId":16604,"journal":{"name":"Journal of Orthodontic Science","volume":"13 ","pages":"49"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11698249/pdf/","citationCount":"0","resultStr":"{\"title\":\"Influence of pH on the release of nickel ions from fixed orthodontic appliances in artificial saliva.\",\"authors\":\"Youssouf Ouédraogo, Abdoul Karim Sakira, Moussa Ouédraogo, Issa Tapsoba, Tarcissus Konsem, Jean Bertin Beugré\",\"doi\":\"10.4103/jos.jos_8_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>The aim of this study was to make a laboratory assessment of pH influence on the kinetics of the release of nickel ions in artificial saliva.</p><p><strong>Methods and material: </strong>In this study, 15 basic orthodontic appliances are immersed in 15 polyethylene tubes each containing 40 ml of artificial saliva. Tubes were divided into three sub-groups of 5 tubes depending on the pH: pH 5, pH 7 and pH 8. The release of nickel ions was measured using atomic absorption spectrometry in a sample of 5 ml of artificial saliva taken one hour, four hours and one hundred and sixty-eight hours after immersion in a water bath at 37°.</p><p><strong>Statistical analysis used: </strong>Significance threshold <i>P</i> was set at 0.05. A Student T test and the 2-way Anova test (with a Bonferoni post-test) were used respectively to compare the means.</p><p><strong>Results: </strong>The neutral pH causes a low release of nickel ions. The release kinetics of nickel ions is minimal for neutral pH, it increases when pH varies. After one hour of immersion, the nickel released did not reach the spectrometer quantification threshold as for neutral and acid pH. The alkaline pH causes an average release of nickel ions from the beginning without kinetic variation. As time passes (T3), the acidic pH causes more nickel ions release through a succession of oxidation-reduction reactions. After 168 hours, the average mass of nickel released is 0.30 µg for pH 7, 1.35 µg for pH 8 and up to 2.85 µg for pH 5.</p><p><strong>Conclusions: </strong>Quantities released did not reach nickel toxicity threshold in humans. Orthodontists must consider the potential risk of hypersensitivity due to nickel in fixed orthodontic appliances.</p>\",\"PeriodicalId\":16604,\"journal\":{\"name\":\"Journal of Orthodontic Science\",\"volume\":\"13 \",\"pages\":\"49\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-11-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11698249/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthodontic Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jos.jos_8_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthodontic Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jos.jos_8_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是实验室评价pH值对人工唾液中镍离子释放动力学的影响。方法和材料:在本研究中,将15个基本正畸器浸入15个聚乙烯管中,每个管中含有40 ml人工唾液。根据pH值,将试管分为三个亚组,每组5个试管:pH 5, pH 7和pH 8。在37°水浴中浸泡1小时、4小时和168小时后,分别取5 ml人工唾液样品,用原子吸收光谱法测量镍离子的释放。采用统计学分析:显著性阈值P为0.05。分别采用Student T检验和2-way Anova检验(含Bonferoni后验检验)比较均值。结果:中性pH导致镍离子的低释放。中性pH下镍离子的释放动力学最小,随pH变化而增加。浸泡1小时后,中性和酸性pH释放的镍未达到光谱仪定量阈值。碱性pH从一开始就导致镍离子的平均释放,没有动力学变化。随着时间的推移(T3),酸性pH值通过一系列氧化还原反应导致更多的镍离子释放。168小时后,pH为7时镍的平均释放质量为0.30µg, pH为8时为1.35µg, pH为5时为2.85µg。结论:释放量未达到人体镍毒性阈值。正畸医师必须考虑固定正畸器具中镍的潜在过敏风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of pH on the release of nickel ions from fixed orthodontic appliances in artificial saliva.

Aim: The aim of this study was to make a laboratory assessment of pH influence on the kinetics of the release of nickel ions in artificial saliva.

Methods and material: In this study, 15 basic orthodontic appliances are immersed in 15 polyethylene tubes each containing 40 ml of artificial saliva. Tubes were divided into three sub-groups of 5 tubes depending on the pH: pH 5, pH 7 and pH 8. The release of nickel ions was measured using atomic absorption spectrometry in a sample of 5 ml of artificial saliva taken one hour, four hours and one hundred and sixty-eight hours after immersion in a water bath at 37°.

Statistical analysis used: Significance threshold P was set at 0.05. A Student T test and the 2-way Anova test (with a Bonferoni post-test) were used respectively to compare the means.

Results: The neutral pH causes a low release of nickel ions. The release kinetics of nickel ions is minimal for neutral pH, it increases when pH varies. After one hour of immersion, the nickel released did not reach the spectrometer quantification threshold as for neutral and acid pH. The alkaline pH causes an average release of nickel ions from the beginning without kinetic variation. As time passes (T3), the acidic pH causes more nickel ions release through a succession of oxidation-reduction reactions. After 168 hours, the average mass of nickel released is 0.30 µg for pH 7, 1.35 µg for pH 8 and up to 2.85 µg for pH 5.

Conclusions: Quantities released did not reach nickel toxicity threshold in humans. Orthodontists must consider the potential risk of hypersensitivity due to nickel in fixed orthodontic appliances.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Orthodontic Science
Journal of Orthodontic Science Dentistry-Orthodontics
CiteScore
0.90
自引率
0.00%
发文量
46
审稿时长
19 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信