{"title":"激光解吸-电离质谱法对小分子的定量分析和测绘:碳基纳米基质和样品制备方案的组合","authors":"Ruochen Guo, Rui Lv, Rui Shi, Enhui Wu, Chongqing Ma, Chang Sun, Govinda Mandal, Jian Liu","doi":"10.1039/d4an01172d","DOIUrl":null,"url":null,"abstract":"The choices of matrices and the protocols of sample deposition are critical factors which are convolving with each other in the matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging. Previous reports on MALDI MS matrices only compared their performance in MS signal intensities, and provided the optical microphotos or MALDI MS images of the sample spots, lacking of quantitative evaluation. There is an urgent need to develop multivariate model to evaluate the performance of different combinations between matrices and sample protocols. Herein we report a weighted multivariate model for quantitative profiling combinations of matrices/protocols systematically. Our work includes three types of carbon-based nano matrices, such as two-dimensional graphite oxide (GO) nanosheets, one-dimensional carbon nanotubes (CNTs), and zero-dimensional graphite dots (GDs). Four representative sample protocols for MALDI MSI, including rapid evaporation, seed layer, sandwich, and dry droplet, are examined in our model. We select five important parameters: (1) planar dispersity grading by SEM, (2) planar fluorescence homogeneity, (3) coefficient variations in MS signals, (4) MS signal-to-noise ratio, and (5) planar MS signal heatmap grading, with individually assigned weights according to their significance in MSI performance. Calculation of the radar chart areas based on our model provides quantitative profiles for individual combinations. Among them, the dry droplet protocol using the matrix of GDs offers the largest radar chart area, indicating a favorable combination choice for MSI. This work proposes a multivariate model to systematically compare different combinations of matrices and sample protocols, promising a useful tool for mapping small molecules by LDI MS.","PeriodicalId":63,"journal":{"name":"Analyst","volume":"28 1","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2025-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantitative Profiling and Mapping of Small Molecules by Laser Desorption-Ionization Mass Spectrometry: Combinations of Carbon-based Nano Matrices and Sample Preparation Protocols\",\"authors\":\"Ruochen Guo, Rui Lv, Rui Shi, Enhui Wu, Chongqing Ma, Chang Sun, Govinda Mandal, Jian Liu\",\"doi\":\"10.1039/d4an01172d\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The choices of matrices and the protocols of sample deposition are critical factors which are convolving with each other in the matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging. Previous reports on MALDI MS matrices only compared their performance in MS signal intensities, and provided the optical microphotos or MALDI MS images of the sample spots, lacking of quantitative evaluation. There is an urgent need to develop multivariate model to evaluate the performance of different combinations between matrices and sample protocols. Herein we report a weighted multivariate model for quantitative profiling combinations of matrices/protocols systematically. Our work includes three types of carbon-based nano matrices, such as two-dimensional graphite oxide (GO) nanosheets, one-dimensional carbon nanotubes (CNTs), and zero-dimensional graphite dots (GDs). Four representative sample protocols for MALDI MSI, including rapid evaporation, seed layer, sandwich, and dry droplet, are examined in our model. We select five important parameters: (1) planar dispersity grading by SEM, (2) planar fluorescence homogeneity, (3) coefficient variations in MS signals, (4) MS signal-to-noise ratio, and (5) planar MS signal heatmap grading, with individually assigned weights according to their significance in MSI performance. Calculation of the radar chart areas based on our model provides quantitative profiles for individual combinations. Among them, the dry droplet protocol using the matrix of GDs offers the largest radar chart area, indicating a favorable combination choice for MSI. This work proposes a multivariate model to systematically compare different combinations of matrices and sample protocols, promising a useful tool for mapping small molecules by LDI MS.\",\"PeriodicalId\":63,\"journal\":{\"name\":\"Analyst\",\"volume\":\"28 1\",\"pages\":\"\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2025-01-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analyst\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1039/d4an01172d\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4an01172d","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
摘要
在基质辅助激光解吸电离(MALDI)质谱成像过程中,基质的选择和样品沉积方案是相互影响的关键因素。以往关于 MALDI 质谱基质的报告仅比较了它们在质谱信号强度方面的性能,并提供了样品点的光学显微照片或 MALDI 质谱图像,缺乏定量评估。目前迫切需要建立多元模型来评估不同基质和样品方案组合的性能。在此,我们报告了一个加权多元模型,用于系统地定量分析基质/方案的组合。我们的工作包括三种碳基纳米基质,如二维氧化石墨(GO)纳米片、一维碳纳米管(CNTs)和零维石墨点(GDs)。我们的模型研究了四种具有代表性的 MALDI MSI 样品方案,包括快速蒸发、种子层、夹层和干液滴。我们选择了五个重要参数:(1) 扫描电镜平面分散性分级;(2) 平面荧光均匀性;(3) MS 信号的系数变化;(4) MS 信噪比;(5) 平面 MS 信号热图分级,并根据它们在 MSI 性能中的重要性分别赋予权重。根据我们的模型计算雷达图区域,可为各个组合提供定量剖面图。其中,使用 GD 矩阵的干液滴方案提供了最大的雷达图面积,表明这是 MSI 的有利组合选择。这项工作提出了一个多变量模型,用于系统地比较不同的基质和样品方案组合,有望成为利用 LDI MS 绘制小分子图谱的有用工具。
Quantitative Profiling and Mapping of Small Molecules by Laser Desorption-Ionization Mass Spectrometry: Combinations of Carbon-based Nano Matrices and Sample Preparation Protocols
The choices of matrices and the protocols of sample deposition are critical factors which are convolving with each other in the matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging. Previous reports on MALDI MS matrices only compared their performance in MS signal intensities, and provided the optical microphotos or MALDI MS images of the sample spots, lacking of quantitative evaluation. There is an urgent need to develop multivariate model to evaluate the performance of different combinations between matrices and sample protocols. Herein we report a weighted multivariate model for quantitative profiling combinations of matrices/protocols systematically. Our work includes three types of carbon-based nano matrices, such as two-dimensional graphite oxide (GO) nanosheets, one-dimensional carbon nanotubes (CNTs), and zero-dimensional graphite dots (GDs). Four representative sample protocols for MALDI MSI, including rapid evaporation, seed layer, sandwich, and dry droplet, are examined in our model. We select five important parameters: (1) planar dispersity grading by SEM, (2) planar fluorescence homogeneity, (3) coefficient variations in MS signals, (4) MS signal-to-noise ratio, and (5) planar MS signal heatmap grading, with individually assigned weights according to their significance in MSI performance. Calculation of the radar chart areas based on our model provides quantitative profiles for individual combinations. Among them, the dry droplet protocol using the matrix of GDs offers the largest radar chart area, indicating a favorable combination choice for MSI. This work proposes a multivariate model to systematically compare different combinations of matrices and sample protocols, promising a useful tool for mapping small molecules by LDI MS.