基于优化工程纳米材料的绿原酸检测电化学传感器的高灵敏度和稳定性

IF 3.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Analyst Pub Date : 2025-01-06 DOI:10.1039/D4AN01483A
Lin-Wei Chen, Nannan Lu and Lei Wang
{"title":"基于优化工程纳米材料的绿原酸检测电化学传感器的高灵敏度和稳定性","authors":"Lin-Wei Chen, Nannan Lu and Lei Wang","doi":"10.1039/D4AN01483A","DOIUrl":null,"url":null,"abstract":"<p >Developing cost-effective and efficient analytical methods is essential for detecting chlorogenic acid (CGA), as excessive consumption of CGA, despite its significant antioxidant, anticancer, and anti-inflammatory properties, can cause serious health problems. The remarkable progress and adjustable features of nanomaterials have significantly improved the analytical capabilities of electrochemical sensors for CGA. This review examines the use of optimally engineered nanomaterials in CGA electrochemical sensors, emphasizing the design and modification strategies of various nanomaterials. It starts with an introduction to the basic principles of electrochemical sensors, detailing their components and the analytical methods employed. Subsequently, the review explores how structural and compositional adjustments in electrocatalysts from different nanomaterial categories enhance CGA detection performance. In conclusion, it discusses the challenges and opportunities linked to designing nanomaterials for modified electrodes in CGA sensors. This review seeks to enhance the understanding of the connection between nanomaterial structures and the performance of CGA electrochemical sensors, offering new perspectives for the future design of highly efficient CGA electrochemical sensors.</p>","PeriodicalId":63,"journal":{"name":"Analyst","volume":" 3","pages":" 447-459"},"PeriodicalIF":3.6000,"publicationDate":"2025-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High-sensitivity and stability electrochemical sensors for chlorogenic acid detection based on optimally engineered nanomaterials\",\"authors\":\"Lin-Wei Chen, Nannan Lu and Lei Wang\",\"doi\":\"10.1039/D4AN01483A\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Developing cost-effective and efficient analytical methods is essential for detecting chlorogenic acid (CGA), as excessive consumption of CGA, despite its significant antioxidant, anticancer, and anti-inflammatory properties, can cause serious health problems. The remarkable progress and adjustable features of nanomaterials have significantly improved the analytical capabilities of electrochemical sensors for CGA. This review examines the use of optimally engineered nanomaterials in CGA electrochemical sensors, emphasizing the design and modification strategies of various nanomaterials. It starts with an introduction to the basic principles of electrochemical sensors, detailing their components and the analytical methods employed. Subsequently, the review explores how structural and compositional adjustments in electrocatalysts from different nanomaterial categories enhance CGA detection performance. In conclusion, it discusses the challenges and opportunities linked to designing nanomaterials for modified electrodes in CGA sensors. This review seeks to enhance the understanding of the connection between nanomaterial structures and the performance of CGA electrochemical sensors, offering new perspectives for the future design of highly efficient CGA electrochemical sensors.</p>\",\"PeriodicalId\":63,\"journal\":{\"name\":\"Analyst\",\"volume\":\" 3\",\"pages\":\" 447-459\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2025-01-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analyst\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2025/an/d4an01483a\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/an/d4an01483a","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

开发经济高效的分析方法对于检测绿原酸(CGA)至关重要,因为尽管绿原酸具有显著的抗氧化、抗癌和抗炎特性,但过量摄入绿原酸会导致严重的健康问题。纳米材料的显著进步和可调特性极大地提高了电化学传感器对CGA的分析能力。本文综述了优化工程纳米材料在CGA电化学传感器中的应用,重点介绍了各种纳米材料的设计和修饰策略。首先介绍了电化学传感器的基本原理,详细介绍了它们的组成和使用的分析方法。随后,综述探讨了不同纳米类别的电催化剂的结构和成分调整如何提高CGA检测性能。最后,讨论了在CGA传感器中设计修饰电极的纳米材料所面临的挑战和机遇。本文旨在加深对纳米材料结构与CGA电化学传感器性能之间关系的理解,为未来设计高效的CGA电化学传感器提供新的视角。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

High-sensitivity and stability electrochemical sensors for chlorogenic acid detection based on optimally engineered nanomaterials

High-sensitivity and stability electrochemical sensors for chlorogenic acid detection based on optimally engineered nanomaterials

Developing cost-effective and efficient analytical methods is essential for detecting chlorogenic acid (CGA), as excessive consumption of CGA, despite its significant antioxidant, anticancer, and anti-inflammatory properties, can cause serious health problems. The remarkable progress and adjustable features of nanomaterials have significantly improved the analytical capabilities of electrochemical sensors for CGA. This review examines the use of optimally engineered nanomaterials in CGA electrochemical sensors, emphasizing the design and modification strategies of various nanomaterials. It starts with an introduction to the basic principles of electrochemical sensors, detailing their components and the analytical methods employed. Subsequently, the review explores how structural and compositional adjustments in electrocatalysts from different nanomaterial categories enhance CGA detection performance. In conclusion, it discusses the challenges and opportunities linked to designing nanomaterials for modified electrodes in CGA sensors. This review seeks to enhance the understanding of the connection between nanomaterial structures and the performance of CGA electrochemical sensors, offering new perspectives for the future design of highly efficient CGA electrochemical sensors.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: "Analyst" journal is the home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信