Mohammed Ahmed Alghauli, Ahmed Yaseen Alqutaibi, Rola Aljohani, Sarah Almuzaini, Musab Hamed Saeed
{"title":"不同打印方向对增材制造树脂牙科器械性能和行为的影响:系统综述和荟萃分析。","authors":"Mohammed Ahmed Alghauli, Ahmed Yaseen Alqutaibi, Rola Aljohani, Sarah Almuzaini, Musab Hamed Saeed","doi":"10.1016/j.prosdent.2024.12.002","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>Different factors affect 3-dimensionally (3D) printed resin products. However, evidence on the effect of the print orientation on resin dental devices is lacking.</p><p><strong>Purpose: </strong>The purpose of this systematic review and meta-analysis was to assess the impact of print orientation on the properties and accuracy of 3D printed implant surgical guides, occlusal devices, clear orthodontic retainers, and aligners.</p><p><strong>Material and methods: </strong>The electronic databases PubMed (MEDLINE), Cochrane, and Scopus were comprehensively searched in July 2024. A modified Consolidated Standards of Reporting Trials (CONSORT) statement was used to judge the included studies, and the data were analyzed by the RevMan 5.4 software program of the Cochrane collaboration by applying an inverse variance analysis (α=.05).</p><p><strong>Results: </strong>Twenty-six records were included. Complete arch, solid surgical guides with horizontal printing orientation exhibited the highest accuracy (P≤.01). Short-span surgical guides printed vertically showed relatively high accuracy (P≤.05). Hollow or mesh devices might not be affected by orientations. Occlusal device accuracy favored horizontal orientation, but correlated with the technology and materials, while the accuracy of orthodontic aligners revealed controversial findings, assuming the limited impact of orientation on orthodontic aligners. The cytotoxicity of occlusal devices was a material-related biological characteristic and unaffected by orientation. Although flexural strength favors horizontal orientation, conflicting results were observed for physical and other mechanical properties due to several variables.</p><p><strong>Conclusions: </strong>Horizontal orientation is recommended for printing complete arch surgical guides, while the accuracy of short surgical guides might favor vertical orientation. The physical mechanical properties depend on the printing orientation, technology, material, and printed parts, but horizontal orientation might produce parts with the best mechanical performance.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of different print orientations on properties and behavior of additively manufactured resin dental devices: A systematic review and meta-analysis.\",\"authors\":\"Mohammed Ahmed Alghauli, Ahmed Yaseen Alqutaibi, Rola Aljohani, Sarah Almuzaini, Musab Hamed Saeed\",\"doi\":\"10.1016/j.prosdent.2024.12.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Statement of problem: </strong>Different factors affect 3-dimensionally (3D) printed resin products. However, evidence on the effect of the print orientation on resin dental devices is lacking.</p><p><strong>Purpose: </strong>The purpose of this systematic review and meta-analysis was to assess the impact of print orientation on the properties and accuracy of 3D printed implant surgical guides, occlusal devices, clear orthodontic retainers, and aligners.</p><p><strong>Material and methods: </strong>The electronic databases PubMed (MEDLINE), Cochrane, and Scopus were comprehensively searched in July 2024. A modified Consolidated Standards of Reporting Trials (CONSORT) statement was used to judge the included studies, and the data were analyzed by the RevMan 5.4 software program of the Cochrane collaboration by applying an inverse variance analysis (α=.05).</p><p><strong>Results: </strong>Twenty-six records were included. Complete arch, solid surgical guides with horizontal printing orientation exhibited the highest accuracy (P≤.01). Short-span surgical guides printed vertically showed relatively high accuracy (P≤.05). Hollow or mesh devices might not be affected by orientations. Occlusal device accuracy favored horizontal orientation, but correlated with the technology and materials, while the accuracy of orthodontic aligners revealed controversial findings, assuming the limited impact of orientation on orthodontic aligners. The cytotoxicity of occlusal devices was a material-related biological characteristic and unaffected by orientation. Although flexural strength favors horizontal orientation, conflicting results were observed for physical and other mechanical properties due to several variables.</p><p><strong>Conclusions: </strong>Horizontal orientation is recommended for printing complete arch surgical guides, while the accuracy of short surgical guides might favor vertical orientation. The physical mechanical properties depend on the printing orientation, technology, material, and printed parts, but horizontal orientation might produce parts with the best mechanical performance.</p>\",\"PeriodicalId\":16866,\"journal\":{\"name\":\"Journal of Prosthetic Dentistry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2025-01-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthetic Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.prosdent.2024.12.002\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2024.12.002","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Influence of different print orientations on properties and behavior of additively manufactured resin dental devices: A systematic review and meta-analysis.
Statement of problem: Different factors affect 3-dimensionally (3D) printed resin products. However, evidence on the effect of the print orientation on resin dental devices is lacking.
Purpose: The purpose of this systematic review and meta-analysis was to assess the impact of print orientation on the properties and accuracy of 3D printed implant surgical guides, occlusal devices, clear orthodontic retainers, and aligners.
Material and methods: The electronic databases PubMed (MEDLINE), Cochrane, and Scopus were comprehensively searched in July 2024. A modified Consolidated Standards of Reporting Trials (CONSORT) statement was used to judge the included studies, and the data were analyzed by the RevMan 5.4 software program of the Cochrane collaboration by applying an inverse variance analysis (α=.05).
Results: Twenty-six records were included. Complete arch, solid surgical guides with horizontal printing orientation exhibited the highest accuracy (P≤.01). Short-span surgical guides printed vertically showed relatively high accuracy (P≤.05). Hollow or mesh devices might not be affected by orientations. Occlusal device accuracy favored horizontal orientation, but correlated with the technology and materials, while the accuracy of orthodontic aligners revealed controversial findings, assuming the limited impact of orientation on orthodontic aligners. The cytotoxicity of occlusal devices was a material-related biological characteristic and unaffected by orientation. Although flexural strength favors horizontal orientation, conflicting results were observed for physical and other mechanical properties due to several variables.
Conclusions: Horizontal orientation is recommended for printing complete arch surgical guides, while the accuracy of short surgical guides might favor vertical orientation. The physical mechanical properties depend on the printing orientation, technology, material, and printed parts, but horizontal orientation might produce parts with the best mechanical performance.
期刊介绍:
The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.