Wan-Zheng Fang , Sathyadevi Palanisamy , Priya Vijayaraghavan , Chiao-Yun Chen , Shun-Long Weng , Chung-Shi Yang , Yun-Ming Wang
{"title":"用于抗苗勒管激素最低水平评估的MOF-on-mof阻抗体原位调控生长的构建。","authors":"Wan-Zheng Fang , Sathyadevi Palanisamy , Priya Vijayaraghavan , Chiao-Yun Chen , Shun-Long Weng , Chung-Shi Yang , Yun-Ming Wang","doi":"10.1016/j.bios.2024.117113","DOIUrl":null,"url":null,"abstract":"<div><div>Anti-mullerian hormone (AMH) detection receives much attention since it is used as an ideal biomarker for quantitative assessment of ovarian reserve. The present study proposed a first report on the use of MOF-on-MOF as an electrochemical sensor for recognizing AMH in buffer and serum media. The MOF-on-MOF, MIL-88 B@UiO66NH<sub>2</sub> was synthesized by the internal extended growth method (IEGM) involving MIL-88 B on UiO66NH<sub>2</sub> by <em>in situ</em> method for the first time. MOF matrix could be established to form a three-dimensional (3D) core-shell hybrid unit using MOFs with distinct characteristics. The morphology, structural characteristics, and electrochemical performance of MIL-88 B@UiO66NH<sub>2</sub> were studied. It was successfully used for AMH sensing to demonstrate the detection performance of the internal extended growth method (IEGM) grown MIL-88 B@UiO66NH<sub>2</sub> made immunosensor. The electrochemical results indicated that MOF-on-MOF exhibited linear EIS response for AMH concentration varying from 100 ng/mL to 1 fg/mL. Further, the immunosensor displayed high specificity and sensitivity for AMH detection. The fabricated sensor attained a remarkable limit of detection (LOD) of 1.07 fg/mL and 0.82 fg/mL, when studied in PBS and 10% serum buffer media, respectively. The biosensor achieved the limit of quantification (LOQ) of 3.25 fg/mL and 2.5 fg/mL, respectively, when analyzed in PBS buffer and 10% serum buffer. The significant results emphasized that the fabricated biosensor holds a promising potential to act as an appropriate tool for rapid assessment of AMH levels.</div></div>","PeriodicalId":259,"journal":{"name":"Biosensors and Bioelectronics","volume":"272 ","pages":"Article 117113"},"PeriodicalIF":10.7000,"publicationDate":"2024-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Construction of in situ modulated controlled growth of MOF-on-mof impedimetric assembly for the practical minimal level assessment of anti-mullerian hormone\",\"authors\":\"Wan-Zheng Fang , Sathyadevi Palanisamy , Priya Vijayaraghavan , Chiao-Yun Chen , Shun-Long Weng , Chung-Shi Yang , Yun-Ming Wang\",\"doi\":\"10.1016/j.bios.2024.117113\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Anti-mullerian hormone (AMH) detection receives much attention since it is used as an ideal biomarker for quantitative assessment of ovarian reserve. The present study proposed a first report on the use of MOF-on-MOF as an electrochemical sensor for recognizing AMH in buffer and serum media. The MOF-on-MOF, MIL-88 B@UiO66NH<sub>2</sub> was synthesized by the internal extended growth method (IEGM) involving MIL-88 B on UiO66NH<sub>2</sub> by <em>in situ</em> method for the first time. MOF matrix could be established to form a three-dimensional (3D) core-shell hybrid unit using MOFs with distinct characteristics. The morphology, structural characteristics, and electrochemical performance of MIL-88 B@UiO66NH<sub>2</sub> were studied. It was successfully used for AMH sensing to demonstrate the detection performance of the internal extended growth method (IEGM) grown MIL-88 B@UiO66NH<sub>2</sub> made immunosensor. The electrochemical results indicated that MOF-on-MOF exhibited linear EIS response for AMH concentration varying from 100 ng/mL to 1 fg/mL. Further, the immunosensor displayed high specificity and sensitivity for AMH detection. The fabricated sensor attained a remarkable limit of detection (LOD) of 1.07 fg/mL and 0.82 fg/mL, when studied in PBS and 10% serum buffer media, respectively. The biosensor achieved the limit of quantification (LOQ) of 3.25 fg/mL and 2.5 fg/mL, respectively, when analyzed in PBS buffer and 10% serum buffer. The significant results emphasized that the fabricated biosensor holds a promising potential to act as an appropriate tool for rapid assessment of AMH levels.</div></div>\",\"PeriodicalId\":259,\"journal\":{\"name\":\"Biosensors and Bioelectronics\",\"volume\":\"272 \",\"pages\":\"Article 117113\"},\"PeriodicalIF\":10.7000,\"publicationDate\":\"2024-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors and Bioelectronics\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0956566324011205\",\"RegionNum\":1,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0956566324011205","RegionNum":1,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOPHYSICS","Score":null,"Total":0}
Construction of in situ modulated controlled growth of MOF-on-mof impedimetric assembly for the practical minimal level assessment of anti-mullerian hormone
Anti-mullerian hormone (AMH) detection receives much attention since it is used as an ideal biomarker for quantitative assessment of ovarian reserve. The present study proposed a first report on the use of MOF-on-MOF as an electrochemical sensor for recognizing AMH in buffer and serum media. The MOF-on-MOF, MIL-88 B@UiO66NH2 was synthesized by the internal extended growth method (IEGM) involving MIL-88 B on UiO66NH2 by in situ method for the first time. MOF matrix could be established to form a three-dimensional (3D) core-shell hybrid unit using MOFs with distinct characteristics. The morphology, structural characteristics, and electrochemical performance of MIL-88 B@UiO66NH2 were studied. It was successfully used for AMH sensing to demonstrate the detection performance of the internal extended growth method (IEGM) grown MIL-88 B@UiO66NH2 made immunosensor. The electrochemical results indicated that MOF-on-MOF exhibited linear EIS response for AMH concentration varying from 100 ng/mL to 1 fg/mL. Further, the immunosensor displayed high specificity and sensitivity for AMH detection. The fabricated sensor attained a remarkable limit of detection (LOD) of 1.07 fg/mL and 0.82 fg/mL, when studied in PBS and 10% serum buffer media, respectively. The biosensor achieved the limit of quantification (LOQ) of 3.25 fg/mL and 2.5 fg/mL, respectively, when analyzed in PBS buffer and 10% serum buffer. The significant results emphasized that the fabricated biosensor holds a promising potential to act as an appropriate tool for rapid assessment of AMH levels.
期刊介绍:
Biosensors & Bioelectronics, along with its open access companion journal Biosensors & Bioelectronics: X, is the leading international publication in the field of biosensors and bioelectronics. It covers research, design, development, and application of biosensors, which are analytical devices incorporating biological materials with physicochemical transducers. These devices, including sensors, DNA chips, electronic noses, and lab-on-a-chip, produce digital signals proportional to specific analytes. Examples include immunosensors and enzyme-based biosensors, applied in various fields such as medicine, environmental monitoring, and food industry. The journal also focuses on molecular and supramolecular structures for enhancing device performance.