Mario Henríquez-Beltrán, Iván D Benítez, Ivan Juez-Garcia, Jordi de Batlle, Thalía Belmonte, Anna Galan Gonzalez, Matías Burgos, Rocio Sanhueza, Claudia Jeria, Daniel Solomons, Adriano D S Targa, Ferran Barbé, Gonzalo Labarca
{"title":"两种不同腕部活动仪在成人人群中的评价。","authors":"Mario Henríquez-Beltrán, Iván D Benítez, Ivan Juez-Garcia, Jordi de Batlle, Thalía Belmonte, Anna Galan Gonzalez, Matías Burgos, Rocio Sanhueza, Claudia Jeria, Daniel Solomons, Adriano D S Targa, Ferran Barbé, Gonzalo Labarca","doi":"10.5664/jcsm.11536","DOIUrl":null,"url":null,"abstract":"<p><strong>Study objectives: </strong>Actigraphy devices are used in sleep medicine. The Actiwatch 2 (Philips Respironics) was an example of a frequently used device in this field. Nevertheless, the discontinuation of this device has led to an increased necessity for the implementation of other available actigraphy methods capable of providing objective information. The objective of this study was to assess the performance of the new ActTrust 2 compared to the Actiwatch 2 model.</p><p><strong>Methods: </strong>This observational prospective study included nine subjects (77.760 activity logs), who were monitored for seven days using two actigraphy wrist devices (ActTrust 2 and Actiwatch 2) simultaneously. The following variables were evaluated: Mesor, amplitude, and acrophase, Intradaily Variability (IV), Interdaily Stability (IS), Relative Amplitude (RA), the mean of five consecutive hours with the lowest activity (L5), and the ten consecutive hours with the highest activity (M10). Furthermore, total sleep time (TST), time in bed (TIB), sleep efficiency (SE), sleep onset latency (SOL), wake after sleep onset (WASO), and awakenings were also included.</p><p><strong>Results: </strong>Actigraphy models indicated statistically significant differences in activity levels. Regarding the analysis of circadian rest-activity rhythms, M10, Mesor, and amplitude also exhibited these differences. Furthermore, the analysis of sleep-wakefulness revealed significant differences in the sleep onset latency (SOL) and the number of awakenings.</p><p><strong>Conclusions: </strong>The ActTrust 2 and Actiwatch 2 models showed equivalent results in measuring circadian rest-activity rhythm and sleep. However, caution is advised when interpreting parameters like Mesor, amplitude, SOL, awakenings, and M10 variables.</p>","PeriodicalId":50233,"journal":{"name":"Journal of Clinical Sleep Medicine","volume":" ","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2025-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of two different wrist actigraphy devices in the adult population.\",\"authors\":\"Mario Henríquez-Beltrán, Iván D Benítez, Ivan Juez-Garcia, Jordi de Batlle, Thalía Belmonte, Anna Galan Gonzalez, Matías Burgos, Rocio Sanhueza, Claudia Jeria, Daniel Solomons, Adriano D S Targa, Ferran Barbé, Gonzalo Labarca\",\"doi\":\"10.5664/jcsm.11536\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Study objectives: </strong>Actigraphy devices are used in sleep medicine. The Actiwatch 2 (Philips Respironics) was an example of a frequently used device in this field. Nevertheless, the discontinuation of this device has led to an increased necessity for the implementation of other available actigraphy methods capable of providing objective information. The objective of this study was to assess the performance of the new ActTrust 2 compared to the Actiwatch 2 model.</p><p><strong>Methods: </strong>This observational prospective study included nine subjects (77.760 activity logs), who were monitored for seven days using two actigraphy wrist devices (ActTrust 2 and Actiwatch 2) simultaneously. The following variables were evaluated: Mesor, amplitude, and acrophase, Intradaily Variability (IV), Interdaily Stability (IS), Relative Amplitude (RA), the mean of five consecutive hours with the lowest activity (L5), and the ten consecutive hours with the highest activity (M10). Furthermore, total sleep time (TST), time in bed (TIB), sleep efficiency (SE), sleep onset latency (SOL), wake after sleep onset (WASO), and awakenings were also included.</p><p><strong>Results: </strong>Actigraphy models indicated statistically significant differences in activity levels. Regarding the analysis of circadian rest-activity rhythms, M10, Mesor, and amplitude also exhibited these differences. Furthermore, the analysis of sleep-wakefulness revealed significant differences in the sleep onset latency (SOL) and the number of awakenings.</p><p><strong>Conclusions: </strong>The ActTrust 2 and Actiwatch 2 models showed equivalent results in measuring circadian rest-activity rhythm and sleep. However, caution is advised when interpreting parameters like Mesor, amplitude, SOL, awakenings, and M10 variables.</p>\",\"PeriodicalId\":50233,\"journal\":{\"name\":\"Journal of Clinical Sleep Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2025-01-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Sleep Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5664/jcsm.11536\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Sleep Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5664/jcsm.11536","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
Evaluation of two different wrist actigraphy devices in the adult population.
Study objectives: Actigraphy devices are used in sleep medicine. The Actiwatch 2 (Philips Respironics) was an example of a frequently used device in this field. Nevertheless, the discontinuation of this device has led to an increased necessity for the implementation of other available actigraphy methods capable of providing objective information. The objective of this study was to assess the performance of the new ActTrust 2 compared to the Actiwatch 2 model.
Methods: This observational prospective study included nine subjects (77.760 activity logs), who were monitored for seven days using two actigraphy wrist devices (ActTrust 2 and Actiwatch 2) simultaneously. The following variables were evaluated: Mesor, amplitude, and acrophase, Intradaily Variability (IV), Interdaily Stability (IS), Relative Amplitude (RA), the mean of five consecutive hours with the lowest activity (L5), and the ten consecutive hours with the highest activity (M10). Furthermore, total sleep time (TST), time in bed (TIB), sleep efficiency (SE), sleep onset latency (SOL), wake after sleep onset (WASO), and awakenings were also included.
Results: Actigraphy models indicated statistically significant differences in activity levels. Regarding the analysis of circadian rest-activity rhythms, M10, Mesor, and amplitude also exhibited these differences. Furthermore, the analysis of sleep-wakefulness revealed significant differences in the sleep onset latency (SOL) and the number of awakenings.
Conclusions: The ActTrust 2 and Actiwatch 2 models showed equivalent results in measuring circadian rest-activity rhythm and sleep. However, caution is advised when interpreting parameters like Mesor, amplitude, SOL, awakenings, and M10 variables.
期刊介绍:
Journal of Clinical Sleep Medicine focuses on clinical sleep medicine. Its emphasis is publication of papers with direct applicability and/or relevance to the clinical practice of sleep medicine. This includes clinical trials, clinical reviews, clinical commentary and debate, medical economic/practice perspectives, case series and novel/interesting case reports. In addition, the journal will publish proceedings from conferences, workshops and symposia sponsored by the American Academy of Sleep Medicine or other organizations related to improving the practice of sleep medicine.