无铅起搏器植入在具有挑战性的情况下:机械三尖瓣患者的病例报告系列。

Q3 Medicine
Surachat Jaroonpipatkul, Sutham Sutheerapatranont, Leenhapong Navaravong, Apichai Pokawattana
{"title":"无铅起搏器植入在具有挑战性的情况下:机械三尖瓣患者的病例报告系列。","authors":"Surachat Jaroonpipatkul, Sutham Sutheerapatranont, Leenhapong Navaravong, Apichai Pokawattana","doi":"10.1016/j.ipej.2024.12.002","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The advancement of medical technology has introduced leadless pacemakers (LPMs) as a significant innovation in cardiac pacing, offering potential advantages over traditional ventricular transvenous pacemakers. This report explores the application of LPMs in two patients with complex valvular histories, particularly those with mechanical tricuspid valves.</p><p><strong>Case reports: </strong>The first case involves a 60-year-old male with a history of rheumatic heart disease and triple valve replacement who developed a high-grade AV block. Due to significant RV pacing, a single-chamber VVI pacemaker using the Micra Transcatheter Pacing System was successfully implanted, navigating the mechanical tricuspid valve with stable pacing parameters. The second case describes a 70-year-old female with HIV, diabetes, hypothyroidism, and multiple valve surgeries presenting with syncope and dyspnea. Given her complex medical history and recurrent conduction issues, the Micra pacemaker was chosen. Despite initial resistance, successful deployment was achieved at the lower septum with acceptable pacing thresholds.</p><p><strong>Discussion: </strong>LPMs offer a promising alternative for patients with mechanical tricuspid valves, eliminating the risks associated with transvenous leads. The Micra system's minimally invasive approach and stable performance in these challenging cases suggest its potential viability in high-risk patients with complex valvular conditions.</p><p><strong>Conclusion: </strong>These cases demonstrate the feasibility of LPM implantation through mechanical tricuspid valves; however, given the associated risks, careful evaluation and meticulous procedural planning are essential before considering this approach.</p>","PeriodicalId":35900,"journal":{"name":"Indian Pacing and Electrophysiology Journal","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Leadless pacemaker implantation in challenging scenarios: A case report series of patients with mechanical tricuspid valves.\",\"authors\":\"Surachat Jaroonpipatkul, Sutham Sutheerapatranont, Leenhapong Navaravong, Apichai Pokawattana\",\"doi\":\"10.1016/j.ipej.2024.12.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The advancement of medical technology has introduced leadless pacemakers (LPMs) as a significant innovation in cardiac pacing, offering potential advantages over traditional ventricular transvenous pacemakers. This report explores the application of LPMs in two patients with complex valvular histories, particularly those with mechanical tricuspid valves.</p><p><strong>Case reports: </strong>The first case involves a 60-year-old male with a history of rheumatic heart disease and triple valve replacement who developed a high-grade AV block. Due to significant RV pacing, a single-chamber VVI pacemaker using the Micra Transcatheter Pacing System was successfully implanted, navigating the mechanical tricuspid valve with stable pacing parameters. The second case describes a 70-year-old female with HIV, diabetes, hypothyroidism, and multiple valve surgeries presenting with syncope and dyspnea. Given her complex medical history and recurrent conduction issues, the Micra pacemaker was chosen. Despite initial resistance, successful deployment was achieved at the lower septum with acceptable pacing thresholds.</p><p><strong>Discussion: </strong>LPMs offer a promising alternative for patients with mechanical tricuspid valves, eliminating the risks associated with transvenous leads. The Micra system's minimally invasive approach and stable performance in these challenging cases suggest its potential viability in high-risk patients with complex valvular conditions.</p><p><strong>Conclusion: </strong>These cases demonstrate the feasibility of LPM implantation through mechanical tricuspid valves; however, given the associated risks, careful evaluation and meticulous procedural planning are essential before considering this approach.</p>\",\"PeriodicalId\":35900,\"journal\":{\"name\":\"Indian Pacing and Electrophysiology Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Pacing and Electrophysiology Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1016/j.ipej.2024.12.002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Pacing and Electrophysiology Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.ipej.2024.12.002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

导读:医疗技术的进步使得无导线起搏器(lpm)成为心脏起搏领域的一项重大创新,与传统的心室经静脉起搏器相比,它具有潜在的优势。本报告探讨了lpm在两例复杂瓣膜病史患者中的应用,特别是那些机械三尖瓣患者。病例报告:第一例患者为60岁男性,有风湿性心脏病和三瓣置换术史,并发高级别房室传导阻滞。由于RV起搏明显,我们成功植入了一个使用Micra经导管起搏系统的单室VVI起搏器,以稳定的起搏参数导航机械三尖瓣。第二个病例描述了一个70岁的女性,患有艾滋病,糖尿病,甲状腺功能减退,多次瓣膜手术,表现为晕厥和呼吸困难。考虑到她复杂的病史和复发性传导问题,我们选择了Micra起搏器。尽管最初有阻力,但在可接受的起搏阈值下,下隔膜成功部署。讨论:lpm为机械三尖瓣患者提供了一个有希望的选择,消除了与经静脉导联相关的风险。Micra系统的微创入路和在这些具有挑战性的病例中的稳定表现表明其在复杂瓣膜疾病的高风险患者中的潜在可行性。结论:通过机械三尖瓣植入LPM是可行的;但是,考虑到相关的风险,在考虑这一办法之前必须进行仔细的评估和周密的程序规划。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Leadless pacemaker implantation in challenging scenarios: A case report series of patients with mechanical tricuspid valves.

Introduction: The advancement of medical technology has introduced leadless pacemakers (LPMs) as a significant innovation in cardiac pacing, offering potential advantages over traditional ventricular transvenous pacemakers. This report explores the application of LPMs in two patients with complex valvular histories, particularly those with mechanical tricuspid valves.

Case reports: The first case involves a 60-year-old male with a history of rheumatic heart disease and triple valve replacement who developed a high-grade AV block. Due to significant RV pacing, a single-chamber VVI pacemaker using the Micra Transcatheter Pacing System was successfully implanted, navigating the mechanical tricuspid valve with stable pacing parameters. The second case describes a 70-year-old female with HIV, diabetes, hypothyroidism, and multiple valve surgeries presenting with syncope and dyspnea. Given her complex medical history and recurrent conduction issues, the Micra pacemaker was chosen. Despite initial resistance, successful deployment was achieved at the lower septum with acceptable pacing thresholds.

Discussion: LPMs offer a promising alternative for patients with mechanical tricuspid valves, eliminating the risks associated with transvenous leads. The Micra system's minimally invasive approach and stable performance in these challenging cases suggest its potential viability in high-risk patients with complex valvular conditions.

Conclusion: These cases demonstrate the feasibility of LPM implantation through mechanical tricuspid valves; however, given the associated risks, careful evaluation and meticulous procedural planning are essential before considering this approach.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indian Pacing and Electrophysiology Journal
Indian Pacing and Electrophysiology Journal Medicine-Cardiology and Cardiovascular Medicine
CiteScore
2.20
自引率
0.00%
发文量
91
审稿时长
61 days
期刊介绍: Indian Pacing and Electrophysiology Journal is a peer reviewed online journal devoted to cardiac pacing and electrophysiology. Editorial Advisory Board includes eminent personalities in the field of cardiac pacing and electrophysiology from Asia, Australia, Europe and North America.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信