基于fpga的64通道读出电子器件用于高分辨率TOF-PET探测器

IF 4.6 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Xiang Zhang;Yonggang Wang;Mingchen Wang;Xiaoguang Kong
{"title":"基于fpga的64通道读出电子器件用于高分辨率TOF-PET探测器","authors":"Xiang Zhang;Yonggang Wang;Mingchen Wang;Xiaoguang Kong","doi":"10.1109/TRPMS.2024.3443831","DOIUrl":null,"url":null,"abstract":"Field programmable logic array (FPGA)-based readout electronics has shown its capability of channel-by-channel signal readout for time-of-flight positron emission tomography (TOF-PET) detectors. However, for detectors that rely on light sharing to achieve subpixel resolution, the high-linear measurement dynamic range of the readout electronics is highly required. In this article, the problems with dynamic range in our previously proposed FPGA-based fast linear discharge circuit are investigated and corresponding methods are proposed to enhance its small signal measurement capability and improve the timing performance as well. A practical 64-channel TOF-PET detector module was constructed and evaluated. The readout electronics test results demonstrated a 240x measurement dynamic range with 99.5% conversion linearity. In the case that the \n<inline-formula> <tex-math>$8\\times 8$ </tex-math></inline-formula>\n silicon photomultiplier (SiPM) array in the detector combines with an \n<inline-formula> <tex-math>$8\\times 8$ </tex-math></inline-formula>\n LYSO crystal (each \n<inline-formula> <tex-math>$3.2\\times 3.2\\times 10$ </tex-math></inline-formula>\n mm3) array, the average energy and coincidence time resolution of the detector are measured as 10.68% (511 keV) and 364.9 ps, respectively. To demonstrate the benefit of large dynamic range to high-resolution detectors, the crystal array in the detector was replaced by a \n<inline-formula> <tex-math>$24\\times 24$ </tex-math></inline-formula>\n LYSO array (each \n<inline-formula> <tex-math>$1.04\\times 1.04\\times 15$ </tex-math></inline-formula>\n mm3) and achieved 1-mm resolution. The test results confirm that the proposed FPGA-based readout circuit is practical for laboratory instrumentation","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":"9 1","pages":"11-19"},"PeriodicalIF":4.6000,"publicationDate":"2024-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An FPGA-Based 64-Channel Readout Electronics for High-Resolution TOF-PET Detectors\",\"authors\":\"Xiang Zhang;Yonggang Wang;Mingchen Wang;Xiaoguang Kong\",\"doi\":\"10.1109/TRPMS.2024.3443831\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Field programmable logic array (FPGA)-based readout electronics has shown its capability of channel-by-channel signal readout for time-of-flight positron emission tomography (TOF-PET) detectors. However, for detectors that rely on light sharing to achieve subpixel resolution, the high-linear measurement dynamic range of the readout electronics is highly required. In this article, the problems with dynamic range in our previously proposed FPGA-based fast linear discharge circuit are investigated and corresponding methods are proposed to enhance its small signal measurement capability and improve the timing performance as well. A practical 64-channel TOF-PET detector module was constructed and evaluated. The readout electronics test results demonstrated a 240x measurement dynamic range with 99.5% conversion linearity. In the case that the \\n<inline-formula> <tex-math>$8\\\\times 8$ </tex-math></inline-formula>\\n silicon photomultiplier (SiPM) array in the detector combines with an \\n<inline-formula> <tex-math>$8\\\\times 8$ </tex-math></inline-formula>\\n LYSO crystal (each \\n<inline-formula> <tex-math>$3.2\\\\times 3.2\\\\times 10$ </tex-math></inline-formula>\\n mm3) array, the average energy and coincidence time resolution of the detector are measured as 10.68% (511 keV) and 364.9 ps, respectively. To demonstrate the benefit of large dynamic range to high-resolution detectors, the crystal array in the detector was replaced by a \\n<inline-formula> <tex-math>$24\\\\times 24$ </tex-math></inline-formula>\\n LYSO array (each \\n<inline-formula> <tex-math>$1.04\\\\times 1.04\\\\times 15$ </tex-math></inline-formula>\\n mm3) and achieved 1-mm resolution. The test results confirm that the proposed FPGA-based readout circuit is practical for laboratory instrumentation\",\"PeriodicalId\":46807,\"journal\":{\"name\":\"IEEE Transactions on Radiation and Plasma Medical Sciences\",\"volume\":\"9 1\",\"pages\":\"11-19\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Radiation and Plasma Medical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10637268/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10637268/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

基于现场可编程逻辑阵列(FPGA)的读出电子器件显示了其对飞行时间正电子发射断层扫描(TOF-PET)探测器逐通道信号读出的能力。然而,对于依靠光共享来实现亚像素分辨率的探测器来说,读出电子器件的高线性测量动态范围是非常必要的。本文研究了前人提出的基于fpga的快速线性放电电路中存在的动态范围问题,并提出了相应的方法来增强其小信号测量能力和改善时序性能。构建了一个实用的64通道TOF-PET检测器模块,并对其进行了评价。读出电子测试结果显示240x的测量动态范围和99.5%的转换线性度。在探测器中的8\ × 8$硅光电倍增管(SiPM)阵列与8\ × 8$ LYSO晶体(每个$3.2\ × 3.2\ × 10$ mm3)阵列相结合的情况下,探测器的平均能量和符合时间分辨率分别为10.68% (511 keV)和364.9 ps。为了展示大动态范围对高分辨率探测器的好处,探测器中的晶体阵列被替换为24\ × 24$ LYSO阵列(每个$1.04\ × 1.04\ × 15$ mm3),并实现了1毫米的分辨率。测试结果证实了所提出的基于fpga的读出电路在实验室仪器中是实用的
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An FPGA-Based 64-Channel Readout Electronics for High-Resolution TOF-PET Detectors
Field programmable logic array (FPGA)-based readout electronics has shown its capability of channel-by-channel signal readout for time-of-flight positron emission tomography (TOF-PET) detectors. However, for detectors that rely on light sharing to achieve subpixel resolution, the high-linear measurement dynamic range of the readout electronics is highly required. In this article, the problems with dynamic range in our previously proposed FPGA-based fast linear discharge circuit are investigated and corresponding methods are proposed to enhance its small signal measurement capability and improve the timing performance as well. A practical 64-channel TOF-PET detector module was constructed and evaluated. The readout electronics test results demonstrated a 240x measurement dynamic range with 99.5% conversion linearity. In the case that the $8\times 8$ silicon photomultiplier (SiPM) array in the detector combines with an $8\times 8$ LYSO crystal (each $3.2\times 3.2\times 10$ mm3) array, the average energy and coincidence time resolution of the detector are measured as 10.68% (511 keV) and 364.9 ps, respectively. To demonstrate the benefit of large dynamic range to high-resolution detectors, the crystal array in the detector was replaced by a $24\times 24$ LYSO array (each $1.04\times 1.04\times 15$ mm3) and achieved 1-mm resolution. The test results confirm that the proposed FPGA-based readout circuit is practical for laboratory instrumentation
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Transactions on Radiation and Plasma Medical Sciences
IEEE Transactions on Radiation and Plasma Medical Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
8.00
自引率
18.20%
发文量
109
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信