基于瘦体重的肝CT造影剂注射方案:造影剂剂量的优化。

IF 9.7 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Damiano Caruso, Domenico De Santis, Antonella Del Gaudio, Daniela Valanzuolo, Dominga Pugliese, Marta Zerunian, Michela Polici, Giuseppe Tremamunno, Benedetta Masci, Andrea Laghi
{"title":"基于瘦体重的肝CT造影剂注射方案:造影剂剂量的优化。","authors":"Damiano Caruso, Domenico De Santis, Antonella Del Gaudio, Daniela Valanzuolo, Dominga Pugliese, Marta Zerunian, Michela Polici, Giuseppe Tremamunno, Benedetta Masci, Andrea Laghi","doi":"10.1007/s11547-024-01944-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate liver enhancement and image quality of abdominal CECT examinations acquired with multiple LBW-based contrast medium injection protocols.</p><p><strong>Material & methods: </strong>One hundred fifty patients who underwent a clinically indicated CECT examination were prospectively and randomly assigned to one of the following contrast medium injection protocol groups: A, 700 mg iodine(I)/kg of LBW; B, 650 mgI/kg of LBW; and C, 600 mgI/kg of LBW. Liver signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and magnitude of contrast enhancement (ΔHU) were calculated. Subjective image quality was assessed with 5-point Likert scale.</p><p><strong>Results: </strong>The final population included 145 patients (64 females), with 50, 48, and 47 in group A, B, and C, respectively. Group A showed significantly higher SNR, CNR and ΔHU than group B (p = .018, p = .004, and p = .031, respectively) and group C (p = .024, p = .043, and p = .004). Group B had similar SNR, CNR, and ΔHU to group C (all p = 1). ΔHU was < 50 HU in 2, 7, and 11 patients in group A (48.2 ± 0.1), B (43.7 ± 5), and C (44.4 ± 5), respectively. Group A achieved the highest scores in terms of overall image quality, artifacts, and diagnostic confidence (both scores: 4; IQRs: 4-5) compared to group B (both scores: 3; IQRs: 3-5; p ≥ .037) and group C (overall image quality score: 3; IQR: 2-5; p = .011. Artifact and diagnostic confidence score: 3; IQR: 1-4; p ≥ .009).</p><p><strong>Conclusions: </strong>A dosage of 700 mgI/kg of LBW yields optimal liver enhancement and grants higher image quality compared to lower contrast medium dosages.</p>","PeriodicalId":20817,"journal":{"name":"Radiologia Medica","volume":" ","pages":""},"PeriodicalIF":9.7000,"publicationDate":"2024-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Lean body weight-based contrast injection protocol in liver CT: optimization of contrast medium dose.\",\"authors\":\"Damiano Caruso, Domenico De Santis, Antonella Del Gaudio, Daniela Valanzuolo, Dominga Pugliese, Marta Zerunian, Michela Polici, Giuseppe Tremamunno, Benedetta Masci, Andrea Laghi\",\"doi\":\"10.1007/s11547-024-01944-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To evaluate liver enhancement and image quality of abdominal CECT examinations acquired with multiple LBW-based contrast medium injection protocols.</p><p><strong>Material & methods: </strong>One hundred fifty patients who underwent a clinically indicated CECT examination were prospectively and randomly assigned to one of the following contrast medium injection protocol groups: A, 700 mg iodine(I)/kg of LBW; B, 650 mgI/kg of LBW; and C, 600 mgI/kg of LBW. Liver signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and magnitude of contrast enhancement (ΔHU) were calculated. Subjective image quality was assessed with 5-point Likert scale.</p><p><strong>Results: </strong>The final population included 145 patients (64 females), with 50, 48, and 47 in group A, B, and C, respectively. Group A showed significantly higher SNR, CNR and ΔHU than group B (p = .018, p = .004, and p = .031, respectively) and group C (p = .024, p = .043, and p = .004). Group B had similar SNR, CNR, and ΔHU to group C (all p = 1). ΔHU was < 50 HU in 2, 7, and 11 patients in group A (48.2 ± 0.1), B (43.7 ± 5), and C (44.4 ± 5), respectively. Group A achieved the highest scores in terms of overall image quality, artifacts, and diagnostic confidence (both scores: 4; IQRs: 4-5) compared to group B (both scores: 3; IQRs: 3-5; p ≥ .037) and group C (overall image quality score: 3; IQR: 2-5; p = .011. Artifact and diagnostic confidence score: 3; IQR: 1-4; p ≥ .009).</p><p><strong>Conclusions: </strong>A dosage of 700 mgI/kg of LBW yields optimal liver enhancement and grants higher image quality compared to lower contrast medium dosages.</p>\",\"PeriodicalId\":20817,\"journal\":{\"name\":\"Radiologia Medica\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":9.7000,\"publicationDate\":\"2024-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiologia Medica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11547-024-01944-2\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiologia Medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11547-024-01944-2","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价多种基于lbw的造影剂注射方案所获得的腹部CECT肝脏增强和图像质量。材料与方法:150例接受临床指征CECT检查的患者前瞻性随机分配到以下对比剂注射方案组:a, 700 mg碘(I)/kg LBW;B, 650 mgI/kg LBW;C为600 mgI/kg LBW。计算肝脏信噪比(SNR)、对比噪声比(CNR)和对比度增强幅度(ΔHU)。主观图像质量采用李克特5分制评价。结果:最终纳入145例患者(女性64例),A、B、C组分别为50例、48例、47例。A组的SNR、CNR和ΔHU均显著高于B组(p =。018, p =。004, p =。031)和C组(p =。024, p =。043, p = .004)。B组SNR、CNR、ΔHU与C组相似(均p = 1)。结论:与较低造影剂剂量相比,700 mgI/kg的LBW剂量可产生最佳的肝脏增强效果,并获得更高的图像质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Lean body weight-based contrast injection protocol in liver CT: optimization of contrast medium dose.

Objectives: To evaluate liver enhancement and image quality of abdominal CECT examinations acquired with multiple LBW-based contrast medium injection protocols.

Material & methods: One hundred fifty patients who underwent a clinically indicated CECT examination were prospectively and randomly assigned to one of the following contrast medium injection protocol groups: A, 700 mg iodine(I)/kg of LBW; B, 650 mgI/kg of LBW; and C, 600 mgI/kg of LBW. Liver signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and magnitude of contrast enhancement (ΔHU) were calculated. Subjective image quality was assessed with 5-point Likert scale.

Results: The final population included 145 patients (64 females), with 50, 48, and 47 in group A, B, and C, respectively. Group A showed significantly higher SNR, CNR and ΔHU than group B (p = .018, p = .004, and p = .031, respectively) and group C (p = .024, p = .043, and p = .004). Group B had similar SNR, CNR, and ΔHU to group C (all p = 1). ΔHU was < 50 HU in 2, 7, and 11 patients in group A (48.2 ± 0.1), B (43.7 ± 5), and C (44.4 ± 5), respectively. Group A achieved the highest scores in terms of overall image quality, artifacts, and diagnostic confidence (both scores: 4; IQRs: 4-5) compared to group B (both scores: 3; IQRs: 3-5; p ≥ .037) and group C (overall image quality score: 3; IQR: 2-5; p = .011. Artifact and diagnostic confidence score: 3; IQR: 1-4; p ≥ .009).

Conclusions: A dosage of 700 mgI/kg of LBW yields optimal liver enhancement and grants higher image quality compared to lower contrast medium dosages.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiologia Medica
Radiologia Medica 医学-核医学
CiteScore
14.10
自引率
7.90%
发文量
133
审稿时长
4-8 weeks
期刊介绍: Felice Perussia founded La radiologia medica in 1914. It is a peer-reviewed journal and serves as the official journal of the Italian Society of Medical and Interventional Radiology (SIRM). The primary purpose of the journal is to disseminate information related to Radiology, especially advancements in diagnostic imaging and related disciplines. La radiologia medica welcomes original research on both fundamental and clinical aspects of modern radiology, with a particular focus on diagnostic and interventional imaging techniques. It also covers topics such as radiotherapy, nuclear medicine, radiobiology, health physics, and artificial intelligence in the context of clinical implications. The journal includes various types of contributions such as original articles, review articles, editorials, short reports, and letters to the editor. With an esteemed Editorial Board and a selection of insightful reports, the journal is an indispensable resource for radiologists and professionals in related fields. Ultimately, La radiologia medica aims to serve as a platform for international collaboration and knowledge sharing within the radiological community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信