重组因子C在动物自体疫苗残留致病性评价中的应用

IF 2 2区 农林科学 Q2 VETERINARY SCIENCES
Antonella Di Paolo, Rosario Liberti, Lucia Anzalone, Claudia Colabella, Andrea Felici, Giulio Severi, Monica Cagiola
{"title":"重组因子C在动物自体疫苗残留致病性评价中的应用","authors":"Antonella Di Paolo, Rosario Liberti, Lucia Anzalone, Claudia Colabella, Andrea Felici, Giulio Severi, Monica Cagiola","doi":"10.3390/vetsci11120673","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Veterinary autogenous vaccines, similar to all injectable pharmaceutical products, must be tested to assess endotoxin concentrations. The Limulus Amebocyte Lysate Test (LAL test) is widely used in in vitro quality control assays for endotoxin detection, although it presents some ethical issues related to the production of reagents and is also characterized by a low specificity due to other contaminants that can activate the reaction. For all these reasons, a new recombinant factor C LAL test was developed.</p><p><strong>Aim: </strong>In this study, we described the comparison between two LAL test methods for in vitro quality control of veterinary autogenous vaccines, with the aim of evaluating the most suitable method and establishing an endotoxin concentration range for two different matrices.</p><p><strong>Methods: </strong>Two hundred batches of two different vaccine matrices were tested using the kinetic chromogenic LAL test and recombinant factor C endotoxin detection assay commercial kits.</p><p><strong>Results and conclusions: </strong>Statistical analysis conducted after the validation of the recombinant factor C test exhibited a statistically significant correlation between the two methods and for both vaccine matrices, suggesting that the animal-free assay can be used as a routine quality control test for veterinary autogenous vaccines.</p>","PeriodicalId":23694,"journal":{"name":"Veterinary Sciences","volume":"11 12","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11680121/pdf/","citationCount":"0","resultStr":"{\"title\":\"Recombinant Factor C as an In Vitro Assay for the Residual Pathogenicity Evaluation of Veterinary Autogenous Vaccines.\",\"authors\":\"Antonella Di Paolo, Rosario Liberti, Lucia Anzalone, Claudia Colabella, Andrea Felici, Giulio Severi, Monica Cagiola\",\"doi\":\"10.3390/vetsci11120673\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Veterinary autogenous vaccines, similar to all injectable pharmaceutical products, must be tested to assess endotoxin concentrations. The Limulus Amebocyte Lysate Test (LAL test) is widely used in in vitro quality control assays for endotoxin detection, although it presents some ethical issues related to the production of reagents and is also characterized by a low specificity due to other contaminants that can activate the reaction. For all these reasons, a new recombinant factor C LAL test was developed.</p><p><strong>Aim: </strong>In this study, we described the comparison between two LAL test methods for in vitro quality control of veterinary autogenous vaccines, with the aim of evaluating the most suitable method and establishing an endotoxin concentration range for two different matrices.</p><p><strong>Methods: </strong>Two hundred batches of two different vaccine matrices were tested using the kinetic chromogenic LAL test and recombinant factor C endotoxin detection assay commercial kits.</p><p><strong>Results and conclusions: </strong>Statistical analysis conducted after the validation of the recombinant factor C test exhibited a statistically significant correlation between the two methods and for both vaccine matrices, suggesting that the animal-free assay can be used as a routine quality control test for veterinary autogenous vaccines.</p>\",\"PeriodicalId\":23694,\"journal\":{\"name\":\"Veterinary Sciences\",\"volume\":\"11 12\",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-12-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11680121/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary Sciences\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.3390/vetsci11120673\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Sciences","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.3390/vetsci11120673","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

背景:兽医自体疫苗,类似于所有可注射药品,必须进行检测以评估内毒素浓度。鲎试剂裂解试验(LAL试验)广泛用于内毒素检测的体外质量控制分析,尽管它存在一些与试剂生产相关的伦理问题,并且由于其他污染物可以激活反应,其特异性较低。基于这些原因,我们开发了一种新的重组因子C LAL检测方法。目的:比较两种动物用自体疫苗体外质量控制的LAL检测方法,以评价两种不同基质的内毒素检测方法的最佳效果,并建立两种不同基质的内毒素浓度范围。方法:采用动态显色LAL试验和重组因子C内毒素检测试剂盒对200批2种不同疫苗基质进行检测。结果和结论:重组因子C试验验证后进行的统计分析显示,两种方法之间以及两种疫苗基质之间存在统计学上显著的相关性,表明无动物试验可作为兽医自体疫苗的常规质量控制试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Recombinant Factor C as an In Vitro Assay for the Residual Pathogenicity Evaluation of Veterinary Autogenous Vaccines.

Background: Veterinary autogenous vaccines, similar to all injectable pharmaceutical products, must be tested to assess endotoxin concentrations. The Limulus Amebocyte Lysate Test (LAL test) is widely used in in vitro quality control assays for endotoxin detection, although it presents some ethical issues related to the production of reagents and is also characterized by a low specificity due to other contaminants that can activate the reaction. For all these reasons, a new recombinant factor C LAL test was developed.

Aim: In this study, we described the comparison between two LAL test methods for in vitro quality control of veterinary autogenous vaccines, with the aim of evaluating the most suitable method and establishing an endotoxin concentration range for two different matrices.

Methods: Two hundred batches of two different vaccine matrices were tested using the kinetic chromogenic LAL test and recombinant factor C endotoxin detection assay commercial kits.

Results and conclusions: Statistical analysis conducted after the validation of the recombinant factor C test exhibited a statistically significant correlation between the two methods and for both vaccine matrices, suggesting that the animal-free assay can be used as a routine quality control test for veterinary autogenous vaccines.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Veterinary Sciences
Veterinary Sciences VETERINARY SCIENCES-
CiteScore
2.90
自引率
8.30%
发文量
612
审稿时长
6 weeks
期刊介绍: Veterinary Sciences is an international and interdisciplinary scholarly open access journal. It publishes original that are relevant to any field of veterinary sciences, including prevention, diagnosis and treatment of disease, disorder and injury in animals. This journal covers almost all topics related to animal health and veterinary medicine. Research fields of interest include but are not limited to: anaesthesiology anatomy bacteriology biochemistry cardiology dentistry dermatology embryology endocrinology epidemiology genetics histology immunology microbiology molecular biology mycology neurobiology oncology ophthalmology parasitology pathology pharmacology physiology radiology surgery theriogenology toxicology virology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信