{"title":"提高阴离子交换膜电解用孔填充膜的性能和耐久性。","authors":"Minyoung Lee, Jin-Soo Park","doi":"10.3390/membranes14120269","DOIUrl":null,"url":null,"abstract":"<p><p>Four distinct pore-filling anion exchange membranes (PFAEMs) were prepared, and their mechanical properties, ion conductivity, and performance in anion exchange membrane water electrolysis (AEMWE) were evaluated. The fabricated PFAEMs demonstrated exceptional tensile strength, which was approximately 14 times higher than that of the commercial membrane, despite being nearly half as thin. Ion conductivity measurements revealed that acrylamide-based membranes outperformed benzyl-based ones, exhibiting 25% and 41% higher conductivity when using crosslinkers with two and three crosslinking sites, respectively. The AEMWE performance directly correlated with the hydrophilicity and ion exchange capacity (IEC) of the membranes. Specifically, AE_3C achieved the highest performance, supported by its superior IEC and ionic conductivity. Durability tests showed that AE_3C outlasted the commercial membrane, with a delayed voltage increase corresponding to its higher IEC, confirming the importance of increased ion-exchange functional groups in ensuring longevity. These results highlight the critical role of hydrophilic monomers and crosslinker structure in optimizing PFAEMs for enhanced performance and durability in AEMWE applications.</p>","PeriodicalId":18410,"journal":{"name":"Membranes","volume":"14 12","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2024-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11678338/pdf/","citationCount":"0","resultStr":"{\"title\":\"Enhanced Performance and Durability of Pore-Filling Membranes for Anion Exchange Membrane Water Electrolysis.\",\"authors\":\"Minyoung Lee, Jin-Soo Park\",\"doi\":\"10.3390/membranes14120269\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Four distinct pore-filling anion exchange membranes (PFAEMs) were prepared, and their mechanical properties, ion conductivity, and performance in anion exchange membrane water electrolysis (AEMWE) were evaluated. The fabricated PFAEMs demonstrated exceptional tensile strength, which was approximately 14 times higher than that of the commercial membrane, despite being nearly half as thin. Ion conductivity measurements revealed that acrylamide-based membranes outperformed benzyl-based ones, exhibiting 25% and 41% higher conductivity when using crosslinkers with two and three crosslinking sites, respectively. The AEMWE performance directly correlated with the hydrophilicity and ion exchange capacity (IEC) of the membranes. Specifically, AE_3C achieved the highest performance, supported by its superior IEC and ionic conductivity. Durability tests showed that AE_3C outlasted the commercial membrane, with a delayed voltage increase corresponding to its higher IEC, confirming the importance of increased ion-exchange functional groups in ensuring longevity. These results highlight the critical role of hydrophilic monomers and crosslinker structure in optimizing PFAEMs for enhanced performance and durability in AEMWE applications.</p>\",\"PeriodicalId\":18410,\"journal\":{\"name\":\"Membranes\",\"volume\":\"14 12\",\"pages\":\"\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11678338/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Membranes\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/membranes14120269\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Membranes","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/membranes14120269","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
Enhanced Performance and Durability of Pore-Filling Membranes for Anion Exchange Membrane Water Electrolysis.
Four distinct pore-filling anion exchange membranes (PFAEMs) were prepared, and their mechanical properties, ion conductivity, and performance in anion exchange membrane water electrolysis (AEMWE) were evaluated. The fabricated PFAEMs demonstrated exceptional tensile strength, which was approximately 14 times higher than that of the commercial membrane, despite being nearly half as thin. Ion conductivity measurements revealed that acrylamide-based membranes outperformed benzyl-based ones, exhibiting 25% and 41% higher conductivity when using crosslinkers with two and three crosslinking sites, respectively. The AEMWE performance directly correlated with the hydrophilicity and ion exchange capacity (IEC) of the membranes. Specifically, AE_3C achieved the highest performance, supported by its superior IEC and ionic conductivity. Durability tests showed that AE_3C outlasted the commercial membrane, with a delayed voltage increase corresponding to its higher IEC, confirming the importance of increased ion-exchange functional groups in ensuring longevity. These results highlight the critical role of hydrophilic monomers and crosslinker structure in optimizing PFAEMs for enhanced performance and durability in AEMWE applications.
MembranesChemical Engineering-Filtration and Separation
CiteScore
6.10
自引率
16.70%
发文量
1071
审稿时长
11 weeks
期刊介绍:
Membranes (ISSN 2077-0375) is an international, peer-reviewed open access journal of separation science and technology. It publishes reviews, research articles, communications and technical notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. Full experimental and/or methodical details must be provided.