术中光谱域光学相干断层成像评价人工晶状体与后囊膜接触的改变对人工晶状体触觉取向的影响。

IF 2.1 4区 医学 Q2 OPHTHALMOLOGY
Naren Shetty, Yash Patel, Reshma Ranade, Akash Jain, Raghav Narasimhan, Apurva Bansod, Rudy Nuijts
{"title":"术中光谱域光学相干断层成像评价人工晶状体与后囊膜接触的改变对人工晶状体触觉取向的影响。","authors":"Naren Shetty, Yash Patel, Reshma Ranade, Akash Jain, Raghav Narasimhan, Apurva Bansod, Rudy Nuijts","doi":"10.4103/IJO.IJO_348_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic-optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT).</p><p><strong>Methods: </strong>Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging. These patients were imaged using intraoperative SD-OCT after implantation of IOL, with the haptics oriented horizontally and then vertically.</p><p><strong>Results: </strong>The vertical height between the posterior surface of the lens capsule and the posterior surface of IOL reduced significantly when the haptics were oriented vertically compared to horizontal orientation. This difference was found on analyzing both vertical as well as horizontal axis scans.</p><p><strong>Conclusion: </strong>We found a greater contact between the posterior capsule and the posterior surface of IOL, with the haptic optic junction of the IOL oriented vertically. This study also suggests the need for newer toric IOL designs which allow vertical orientation of haptics, leading to better contact between IOL and the bag.</p>","PeriodicalId":13329,"journal":{"name":"Indian Journal of Ophthalmology","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2024-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of change in the contact of IOL with the posterior capsule with respect to the orientation of haptics of the IOL using intraoperative spectral domain optical coherence tomography.\",\"authors\":\"Naren Shetty, Yash Patel, Reshma Ranade, Akash Jain, Raghav Narasimhan, Apurva Bansod, Rudy Nuijts\",\"doi\":\"10.4103/IJO.IJO_348_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic-optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT).</p><p><strong>Methods: </strong>Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging. These patients were imaged using intraoperative SD-OCT after implantation of IOL, with the haptics oriented horizontally and then vertically.</p><p><strong>Results: </strong>The vertical height between the posterior surface of the lens capsule and the posterior surface of IOL reduced significantly when the haptics were oriented vertically compared to horizontal orientation. This difference was found on analyzing both vertical as well as horizontal axis scans.</p><p><strong>Conclusion: </strong>We found a greater contact between the posterior capsule and the posterior surface of IOL, with the haptic optic junction of the IOL oriented vertically. This study also suggests the need for newer toric IOL designs which allow vertical orientation of haptics, leading to better contact between IOL and the bag.</p>\",\"PeriodicalId\":13329,\"journal\":{\"name\":\"Indian Journal of Ophthalmology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-12-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4103/IJO.IJO_348_24\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/IJO.IJO_348_24","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:应用术中光谱域光学相干断层扫描(SD-OCT)研究人工晶状体(IOL)与后囊膜接触的变化与IOL触觉-光学连接点的垂直方向和水平方向的关系。方法:50例老年性未成熟白内障患者50眼,由一位经验丰富的外科医生行局部超声乳化术联合单焦点人工晶体植入术。术中成像使用Rescan 700 SD-OCT系统。这些患者在人工晶状体植入术中采用SD-OCT成像,触觉先水平后垂直。结果:与水平定向相比,垂直定向时晶状体囊后表面与人工晶状体后表面之间的垂直高度明显降低。这种差异是在分析垂直和水平轴扫描时发现的。结论:人工晶状体后囊与晶状体后表面有较大的接触,晶状体的视触觉结垂直取向。这项研究也表明需要更新的环形人工晶状体设计,允许垂直方向的触觉,使人工晶状体和眼袋之间更好地接触。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of change in the contact of IOL with the posterior capsule with respect to the orientation of haptics of the IOL using intraoperative spectral domain optical coherence tomography.

Purpose: To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic-optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT).

Methods: Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging. These patients were imaged using intraoperative SD-OCT after implantation of IOL, with the haptics oriented horizontally and then vertically.

Results: The vertical height between the posterior surface of the lens capsule and the posterior surface of IOL reduced significantly when the haptics were oriented vertically compared to horizontal orientation. This difference was found on analyzing both vertical as well as horizontal axis scans.

Conclusion: We found a greater contact between the posterior capsule and the posterior surface of IOL, with the haptic optic junction of the IOL oriented vertically. This study also suggests the need for newer toric IOL designs which allow vertical orientation of haptics, leading to better contact between IOL and the bag.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.80
自引率
19.40%
发文量
1963
审稿时长
38 weeks
期刊介绍: Indian Journal of Ophthalmology covers clinical, experimental, basic science research and translational research studies related to medical, ethical and social issues in field of ophthalmology and vision science. Articles with clinical interest and implications will be given preference.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信