{"title":"荧光微球试纸灵敏定量检测依托咪酯和甲咪酯","authors":"Qingqing Liu, Xinxin Xu, Liqiang Liu, Aihua Qu, Chuanlai Xu and Hua Kuang","doi":"10.1039/D4AN01213E","DOIUrl":null,"url":null,"abstract":"<p >In this research, we fabricated a sensitive monoclonal antibody (mAb) 2C3 that targeted etomidate (ET) and metomidate (MT) to establish a lateral-flow immunoassay (LFIA) that incorporated fluorescent microsphere sensors, enabling both the qualitative and quantitative detection of ET and MT within 10 min. Analysis indicated that the visual colorimetric values for ET and MT in water samples were 0.3 μg kg<small><sup>−1</sup></small>, respectively, with quantitative detection ranges of 0.08 to 1.31 μg kg<small><sup>−1</sup></small> and 0.08 to 2.21 μg kg<small><sup>−1</sup></small>, respectively. The visual colorimetric values for ET and MT in urine samples were 0.3 and 1 μg kg<small><sup>−1</sup></small>, respectively, with quantitative detection ranges of 0.12 to 3.13 μg kg<small><sup>−1</sup></small> and 0.09 to 2.98, respectively, while for ET and MT in serum samples were 3 μg kg<small><sup>−1</sup></small>, with quantitative detection ranges of 0.15 to 21.2 μg kg<small><sup>−1</sup></small> and 0.08 to 13.8 μg kg<small><sup>−1</sup></small>, respectively. Recovery tests and detection were conducted in water, urine and serum samples, validating the reliability of this method in clinical samples, consistent with those obtained from LC-MS/MS. Collectively, our novel LFIA provides a promising option for rapid on-site detection of ET and MT.</p>","PeriodicalId":63,"journal":{"name":"Analyst","volume":" 3","pages":" 542-551"},"PeriodicalIF":3.6000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fluorescent microsphere-based strip for sensitive and quantitative detection of etomidate and metomidate†\",\"authors\":\"Qingqing Liu, Xinxin Xu, Liqiang Liu, Aihua Qu, Chuanlai Xu and Hua Kuang\",\"doi\":\"10.1039/D4AN01213E\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >In this research, we fabricated a sensitive monoclonal antibody (mAb) 2C3 that targeted etomidate (ET) and metomidate (MT) to establish a lateral-flow immunoassay (LFIA) that incorporated fluorescent microsphere sensors, enabling both the qualitative and quantitative detection of ET and MT within 10 min. Analysis indicated that the visual colorimetric values for ET and MT in water samples were 0.3 μg kg<small><sup>−1</sup></small>, respectively, with quantitative detection ranges of 0.08 to 1.31 μg kg<small><sup>−1</sup></small> and 0.08 to 2.21 μg kg<small><sup>−1</sup></small>, respectively. The visual colorimetric values for ET and MT in urine samples were 0.3 and 1 μg kg<small><sup>−1</sup></small>, respectively, with quantitative detection ranges of 0.12 to 3.13 μg kg<small><sup>−1</sup></small> and 0.09 to 2.98, respectively, while for ET and MT in serum samples were 3 μg kg<small><sup>−1</sup></small>, with quantitative detection ranges of 0.15 to 21.2 μg kg<small><sup>−1</sup></small> and 0.08 to 13.8 μg kg<small><sup>−1</sup></small>, respectively. Recovery tests and detection were conducted in water, urine and serum samples, validating the reliability of this method in clinical samples, consistent with those obtained from LC-MS/MS. Collectively, our novel LFIA provides a promising option for rapid on-site detection of ET and MT.</p>\",\"PeriodicalId\":63,\"journal\":{\"name\":\"Analyst\",\"volume\":\" 3\",\"pages\":\" 542-551\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2024-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analyst\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2025/an/d4an01213e\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/an/d4an01213e","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

在这项研究中,我们利用一种新的半抗原产生了一种针对依托咪酯(ET)和美托咪酯(MT)的敏感单克隆抗体(mAb) 2C3。我们利用该单抗建立了一种结合荧光微球传感器的侧流免疫分析法(LFIA),可以在10分钟内对ET和MT进行定性和定量检测。分析表明,水样中ET和MT的视觉比色值分别为0.3µg/kg,定量检测范围分别为0.08 ~ 1.31µg/kg和0.08 ~ 2.21µg/kg。尿液样品中ET和MT的视觉比色值为0.3 ~ 1µg/kg,定量检测范围分别为0.12 ~ 3.13µg/kg和0.09 ~ 2.98。血清样品中ET和MT的视觉比色值为3µg/kg,定量检测范围分别为0.15 ~ 21.2µg/kg和0.08 ~ 13.8µg/kg。在水、尿、血清样品中进行了回收率试验和检测,验证了该方法在实际临床样品中的可靠性。总的来说,我们的新型LFIA为快速现场检测ET和MT提供了一个有前途的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Fluorescent microsphere-based strip for sensitive and quantitative detection of etomidate and metomidate†

Fluorescent microsphere-based strip for sensitive and quantitative detection of etomidate and metomidate†

In this research, we fabricated a sensitive monoclonal antibody (mAb) 2C3 that targeted etomidate (ET) and metomidate (MT) to establish a lateral-flow immunoassay (LFIA) that incorporated fluorescent microsphere sensors, enabling both the qualitative and quantitative detection of ET and MT within 10 min. Analysis indicated that the visual colorimetric values for ET and MT in water samples were 0.3 μg kg−1, respectively, with quantitative detection ranges of 0.08 to 1.31 μg kg−1 and 0.08 to 2.21 μg kg−1, respectively. The visual colorimetric values for ET and MT in urine samples were 0.3 and 1 μg kg−1, respectively, with quantitative detection ranges of 0.12 to 3.13 μg kg−1 and 0.09 to 2.98, respectively, while for ET and MT in serum samples were 3 μg kg−1, with quantitative detection ranges of 0.15 to 21.2 μg kg−1 and 0.08 to 13.8 μg kg−1, respectively. Recovery tests and detection were conducted in water, urine and serum samples, validating the reliability of this method in clinical samples, consistent with those obtained from LC-MS/MS. Collectively, our novel LFIA provides a promising option for rapid on-site detection of ET and MT.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: "Analyst" journal is the home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信