Pradipta Debnath, Jean A Tkach, Zachary R Abramson, Nadeen K Abu Ata, Brian D Coley, Katherine N Epstein, Lindsay Griffin, Bin Zhang, Andrew T Trout, Jonathan Dillman, Cara E Morin
{"title":"儿童和年轻人腹部多波段与常规弥散加权MRI对比。","authors":"Pradipta Debnath, Jean A Tkach, Zachary R Abramson, Nadeen K Abu Ata, Brian D Coley, Katherine N Epstein, Lindsay Griffin, Bin Zhang, Andrew T Trout, Jonathan Dillman, Cara E Morin","doi":"10.1007/s00261-024-04765-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Implementation of diffusion-weighted imaging (DWI) for abdominal imaging in children has challenges due to motion artifacts exacerbated by long acquisition times. We aimed to compare acquisition time and image quality between conventional DWI and multi-band (MB) DWI of the liver in children and young adults.</p><p><strong>Methods: </strong>Clinical MRI exams from May 2023 to January 2024 were reviewed, including four DWI sequences: respiratory-triggered (RTr, clinical standard), free-breathing (FB), MB-DWI with shift factor 1 (MBsf1), and MB-DWI with shift factor 2 (MBsf2). Acquisition times were recorded, and signal intensity and apparent signal-to-noise ratio (aSNR) were calculated for the liver and spleen. Six blinded pediatric radiologists independently assessed image quality, artifacts, and lesion visualization on a 5-point Likert scale and identified their preferred sequence. Statistical comparisons were made using Kruskal-Wallis and ANOVA tests.</p><p><strong>Results: </strong>Median acquisition times were significantly reduced with MB-DWI (43 s for MBsf1/MBsf2) compared to FB (84 s) and RTr (240 s). Image quality and artifact scores were highest for RTr and FB sequences (p < 0.0001). Mean image quality scores were 3.7 (RTr, FB), 3.4 (MBsf1), and 3.5 (MBsf2), while artifact scores followed a similar trend (higher score = fewer artifacts). Lesion visualization scores were comparable across sequences (p = 0.11), and reviewers expressed no preference in 47% of cases. Apparent diffusion coefficient (ADC) values were consistent across all sequences (p > 0.05).</p><p><strong>Conclusion: </strong>MB-DWI significantly reduces acquisition time while maintaining acceptable image quality and lesion visualization, making it a valuable option for pediatric abdominal MRI.</p>","PeriodicalId":7126,"journal":{"name":"Abdominal Radiology","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multi-band vs. conventional diffusion-weighted MRI of the abdomen in children and young adults.\",\"authors\":\"Pradipta Debnath, Jean A Tkach, Zachary R Abramson, Nadeen K Abu Ata, Brian D Coley, Katherine N Epstein, Lindsay Griffin, Bin Zhang, Andrew T Trout, Jonathan Dillman, Cara E Morin\",\"doi\":\"10.1007/s00261-024-04765-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Implementation of diffusion-weighted imaging (DWI) for abdominal imaging in children has challenges due to motion artifacts exacerbated by long acquisition times. We aimed to compare acquisition time and image quality between conventional DWI and multi-band (MB) DWI of the liver in children and young adults.</p><p><strong>Methods: </strong>Clinical MRI exams from May 2023 to January 2024 were reviewed, including four DWI sequences: respiratory-triggered (RTr, clinical standard), free-breathing (FB), MB-DWI with shift factor 1 (MBsf1), and MB-DWI with shift factor 2 (MBsf2). Acquisition times were recorded, and signal intensity and apparent signal-to-noise ratio (aSNR) were calculated for the liver and spleen. Six blinded pediatric radiologists independently assessed image quality, artifacts, and lesion visualization on a 5-point Likert scale and identified their preferred sequence. Statistical comparisons were made using Kruskal-Wallis and ANOVA tests.</p><p><strong>Results: </strong>Median acquisition times were significantly reduced with MB-DWI (43 s for MBsf1/MBsf2) compared to FB (84 s) and RTr (240 s). Image quality and artifact scores were highest for RTr and FB sequences (p < 0.0001). Mean image quality scores were 3.7 (RTr, FB), 3.4 (MBsf1), and 3.5 (MBsf2), while artifact scores followed a similar trend (higher score = fewer artifacts). Lesion visualization scores were comparable across sequences (p = 0.11), and reviewers expressed no preference in 47% of cases. Apparent diffusion coefficient (ADC) values were consistent across all sequences (p > 0.05).</p><p><strong>Conclusion: </strong>MB-DWI significantly reduces acquisition time while maintaining acceptable image quality and lesion visualization, making it a valuable option for pediatric abdominal MRI.</p>\",\"PeriodicalId\":7126,\"journal\":{\"name\":\"Abdominal Radiology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-12-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Abdominal Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00261-024-04765-z\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Abdominal Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00261-024-04765-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Multi-band vs. conventional diffusion-weighted MRI of the abdomen in children and young adults.
Objectives: Implementation of diffusion-weighted imaging (DWI) for abdominal imaging in children has challenges due to motion artifacts exacerbated by long acquisition times. We aimed to compare acquisition time and image quality between conventional DWI and multi-band (MB) DWI of the liver in children and young adults.
Methods: Clinical MRI exams from May 2023 to January 2024 were reviewed, including four DWI sequences: respiratory-triggered (RTr, clinical standard), free-breathing (FB), MB-DWI with shift factor 1 (MBsf1), and MB-DWI with shift factor 2 (MBsf2). Acquisition times were recorded, and signal intensity and apparent signal-to-noise ratio (aSNR) were calculated for the liver and spleen. Six blinded pediatric radiologists independently assessed image quality, artifacts, and lesion visualization on a 5-point Likert scale and identified their preferred sequence. Statistical comparisons were made using Kruskal-Wallis and ANOVA tests.
Results: Median acquisition times were significantly reduced with MB-DWI (43 s for MBsf1/MBsf2) compared to FB (84 s) and RTr (240 s). Image quality and artifact scores were highest for RTr and FB sequences (p < 0.0001). Mean image quality scores were 3.7 (RTr, FB), 3.4 (MBsf1), and 3.5 (MBsf2), while artifact scores followed a similar trend (higher score = fewer artifacts). Lesion visualization scores were comparable across sequences (p = 0.11), and reviewers expressed no preference in 47% of cases. Apparent diffusion coefficient (ADC) values were consistent across all sequences (p > 0.05).
Conclusion: MB-DWI significantly reduces acquisition time while maintaining acceptable image quality and lesion visualization, making it a valuable option for pediatric abdominal MRI.
期刊介绍:
Abdominal Radiology seeks to meet the professional needs of the abdominal radiologist by publishing clinically pertinent original, review and practice related articles on the gastrointestinal and genitourinary tracts and abdominal interventional and radiologic procedures. Case reports are generally not accepted unless they are the first report of a new disease or condition, or part of a special solicited section.
Reasons to Publish Your Article in Abdominal Radiology:
· Official journal of the Society of Abdominal Radiology (SAR)
· Published in Cooperation with:
European Society of Gastrointestinal and Abdominal Radiology (ESGAR)
European Society of Urogenital Radiology (ESUR)
Asian Society of Abdominal Radiology (ASAR)
· Efficient handling and Expeditious review
· Author feedback is provided in a mentoring style
· Global readership
· Readers can earn CME credits