{"title":"用有限元分析评价患者的球形附着覆盖义齿修复。","authors":"Hatice Özdemir, Burak Hülagü","doi":"10.4012/dmj.2024-252","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to apply finite element analysis (FEA) to simulate the oral environment of a patient with an implant-supported overdenture prosthesis. A 3D mandibular model was created for a 45-year-old female patient from CT images, with mucosal thickness measured at 3 mm on average using ultrasonography. The overdenture prosthesis was scanned with an intraoral scanner and placed onto the 3D mandibular model. Displacement of the prosthesis and von Mises stress values of the implant, surrounding bone tissue, implant-prosthesis components, and mucosa were calculated under various masticatory loads. The study found that anterior mastication generated higher stress compared to unilateral and bilateral mastication. The addition of a third implant significantly reduced stress and improved prosthesis stability, particularly during bilateral mastication.</p>","PeriodicalId":11065,"journal":{"name":"Dental materials journal","volume":" ","pages":"112-120"},"PeriodicalIF":1.9000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation with finite element analysis of a ball attachment overdenture prosthesis of a patient.\",\"authors\":\"Hatice Özdemir, Burak Hülagü\",\"doi\":\"10.4012/dmj.2024-252\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to apply finite element analysis (FEA) to simulate the oral environment of a patient with an implant-supported overdenture prosthesis. A 3D mandibular model was created for a 45-year-old female patient from CT images, with mucosal thickness measured at 3 mm on average using ultrasonography. The overdenture prosthesis was scanned with an intraoral scanner and placed onto the 3D mandibular model. Displacement of the prosthesis and von Mises stress values of the implant, surrounding bone tissue, implant-prosthesis components, and mucosa were calculated under various masticatory loads. The study found that anterior mastication generated higher stress compared to unilateral and bilateral mastication. The addition of a third implant significantly reduced stress and improved prosthesis stability, particularly during bilateral mastication.</p>\",\"PeriodicalId\":11065,\"journal\":{\"name\":\"Dental materials journal\",\"volume\":\" \",\"pages\":\"112-120\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental materials journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.4012/dmj.2024-252\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental materials journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.4012/dmj.2024-252","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Evaluation with finite element analysis of a ball attachment overdenture prosthesis of a patient.
This study aimed to apply finite element analysis (FEA) to simulate the oral environment of a patient with an implant-supported overdenture prosthesis. A 3D mandibular model was created for a 45-year-old female patient from CT images, with mucosal thickness measured at 3 mm on average using ultrasonography. The overdenture prosthesis was scanned with an intraoral scanner and placed onto the 3D mandibular model. Displacement of the prosthesis and von Mises stress values of the implant, surrounding bone tissue, implant-prosthesis components, and mucosa were calculated under various masticatory loads. The study found that anterior mastication generated higher stress compared to unilateral and bilateral mastication. The addition of a third implant significantly reduced stress and improved prosthesis stability, particularly during bilateral mastication.
期刊介绍:
Dental Materials Journal is a peer review journal published by the Japanese Society for Dental Materials and Devises aiming to introduce the progress of the basic and applied sciences in dental materials and biomaterials. The dental materials-related clinical science and instrumental technologies are also within the scope of this journal. The materials dealt include synthetic polymers, ceramics, metals and tissue-derived biomaterials. Forefront dental materials and biomaterials used in developing filed, such as tissue engineering, bioengineering and artificial intelligence, are positively considered for the review as well. Recent acceptance rate of the submitted manuscript in the journal is around 30%.