两个对称角膜环植入三级圆锥角膜的临床结果:一项回顾性非随机研究。

IF 1.7 4区 医学 Q3 OPHTHALMOLOGY
Amr Mounir, Islam Awny, Ibrahim Amer, Alaa Mahmoud, Elshimaa AMateen Mossa
{"title":"两个对称角膜环植入三级圆锥角膜的临床结果:一项回顾性非随机研究。","authors":"Amr Mounir, Islam Awny, Ibrahim Amer, Alaa Mahmoud, Elshimaa AMateen Mossa","doi":"10.1186/s12886-024-03796-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the clinical outcomes of implanting two symmetrical Kerarings via a femtosecond laser in grade three keratoconus.</p><p><strong>Patients and methods: </strong>This was a retrospective nonrandomized controlled clinical study. The study included one eye from each of twenty-three patients, all with Grade 3 keratoconus as classified by the Amsler-Krumeich classification. The ICRS surgery was performed with the patient under topical anaesthesia (benoxinate hydrochloride 4 mg/mL 0.4%). A tunnel channel was created by a femtosecond laser using a 60-kHz infrared neodymium glass femtosecond laser at a wavelength of 1053 nm (Abbott Laboratories Inc., Abbott Park, Illinois, USA). Two symmetrical Kerarings (Mediphacos Inc., Belo Horizonte, Brazil) were implanted in all the cases with 160° arcs and 250,300 µm thicknesses according to the corneal thickness at the implantation site. After surgery, the patients underwent a full ocular evaluation on Days 1, 7, and 14 and after one month. For a period of 1 year, corneal topography readings were taken quarterly, and the numbers of Pentacam measurements were averaged.</p><p><strong>Results: </strong>Twenty-three eyes of twenty-three patients were included in this study. The mean value (± SD) of age was 22.8 (± 6.84) years. Six (26.09%) eyes were from males, and 17 (73.91%) were from females. The cone location was central for all patients. Spherical error, cylindrical error, spherical equivalent (SE), uncorrected visual acuity (UCVA), and best corrected visual acuity (BCVA) significantly improved after 3, 6, 9, and 12 months compared with the preoperative values (P value < 0.001). There was no significant difference in the axial and pachymetry readings before and after surgery. Kmax flattened insignificantly at 3 and 6 months of follow-up, whereas significant flattening was achieved at 9 and 12 months (P values = 0.046 and 0.042, respectively). The K mean, K1, K2, anterior elevation, topographic cylinder, and Q value posterior to the corneal surface were significantly lower at the 3-, 6-, 9- and 12-month follow-up visits than preoperatively (P value < 0.05). Posterior elevation and the Q value of the anterior corneal surface were significantly greater after surgery (3, 6, 9, and 12 months) than before surgery (P value < 0.05). With respect to the Belin ABCD grading system, A and D significantly improved throughout the follow-up visits (3, 6, 9, and 12 months) (P value < 0.001), whereas B and C did not significantly differ between the 3-, 6-, 9- and 12-month follow-up visits and the preoperative values.</p><p><strong>Conclusion: </strong>Grade 3 KC, with the central cone managed with two symmetrical kera-rings, showed favourable results with respect to clinical and topographic outcomes, with improvements in the ABCD staging system of KC.</p>","PeriodicalId":9058,"journal":{"name":"BMC Ophthalmology","volume":"24 1","pages":"543"},"PeriodicalIF":1.7000,"publicationDate":"2024-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11662518/pdf/","citationCount":"0","resultStr":"{\"title\":\"Clinical outcomes of two symmetrical Kera-rings implanted in grade three keratoconus: a retrospective nonrandomized study.\",\"authors\":\"Amr Mounir, Islam Awny, Ibrahim Amer, Alaa Mahmoud, Elshimaa AMateen Mossa\",\"doi\":\"10.1186/s12886-024-03796-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the clinical outcomes of implanting two symmetrical Kerarings via a femtosecond laser in grade three keratoconus.</p><p><strong>Patients and methods: </strong>This was a retrospective nonrandomized controlled clinical study. The study included one eye from each of twenty-three patients, all with Grade 3 keratoconus as classified by the Amsler-Krumeich classification. The ICRS surgery was performed with the patient under topical anaesthesia (benoxinate hydrochloride 4 mg/mL 0.4%). A tunnel channel was created by a femtosecond laser using a 60-kHz infrared neodymium glass femtosecond laser at a wavelength of 1053 nm (Abbott Laboratories Inc., Abbott Park, Illinois, USA). Two symmetrical Kerarings (Mediphacos Inc., Belo Horizonte, Brazil) were implanted in all the cases with 160° arcs and 250,300 µm thicknesses according to the corneal thickness at the implantation site. After surgery, the patients underwent a full ocular evaluation on Days 1, 7, and 14 and after one month. For a period of 1 year, corneal topography readings were taken quarterly, and the numbers of Pentacam measurements were averaged.</p><p><strong>Results: </strong>Twenty-three eyes of twenty-three patients were included in this study. The mean value (± SD) of age was 22.8 (± 6.84) years. Six (26.09%) eyes were from males, and 17 (73.91%) were from females. The cone location was central for all patients. Spherical error, cylindrical error, spherical equivalent (SE), uncorrected visual acuity (UCVA), and best corrected visual acuity (BCVA) significantly improved after 3, 6, 9, and 12 months compared with the preoperative values (P value < 0.001). There was no significant difference in the axial and pachymetry readings before and after surgery. Kmax flattened insignificantly at 3 and 6 months of follow-up, whereas significant flattening was achieved at 9 and 12 months (P values = 0.046 and 0.042, respectively). The K mean, K1, K2, anterior elevation, topographic cylinder, and Q value posterior to the corneal surface were significantly lower at the 3-, 6-, 9- and 12-month follow-up visits than preoperatively (P value < 0.05). Posterior elevation and the Q value of the anterior corneal surface were significantly greater after surgery (3, 6, 9, and 12 months) than before surgery (P value < 0.05). With respect to the Belin ABCD grading system, A and D significantly improved throughout the follow-up visits (3, 6, 9, and 12 months) (P value < 0.001), whereas B and C did not significantly differ between the 3-, 6-, 9- and 12-month follow-up visits and the preoperative values.</p><p><strong>Conclusion: </strong>Grade 3 KC, with the central cone managed with two symmetrical kera-rings, showed favourable results with respect to clinical and topographic outcomes, with improvements in the ABCD staging system of KC.</p>\",\"PeriodicalId\":9058,\"journal\":{\"name\":\"BMC Ophthalmology\",\"volume\":\"24 1\",\"pages\":\"543\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-12-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11662518/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12886-024-03796-w\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12886-024-03796-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价飞秒激光在三级圆锥角膜内植入两对称角角膜的临床效果。患者和方法:这是一项回顾性非随机对照临床研究。该研究包括23名患者的一只眼睛,所有患者均为三级圆锥角膜,按Amsler-Krumeich分级。患者在表面麻醉(盐酸苯氧酸盐4mg /mL 0.4%)下进行ICRS手术。利用波长为1053 nm的60 khz红外钕玻璃飞秒激光(Abbott Laboratories Inc., Abbott Park, Illinois, USA)创建了一个隧道通道。根据植入部位角膜厚度,所有病例均植入两枚对称角圈(Mediphacos Inc., Belo Horizonte, Brazil),圆度160°,厚度250,300µm。手术后,患者在第1、7、14天和1个月后接受全面的眼部评估。在1年的时间里,每季度进行一次角膜地形图读数,并取Pentacam测量次数的平均值。结果:本研究纳入23例患者的23只眼。年龄平均值(±SD)为22.8(±6.84)岁。男性6只(26.09%),女性17只(73.91%)。所有患者的锥体位置均为中心。3个月、6个月、9个月和12个月后,与术前相比,球面误差、圆柱误差、球面等效(SE)、未矫正视力(UCVA)和最佳矫正视力(BCVA)均有显著改善(P值)。结论:3级KC,中心锥采用两个对称的角膜环管理,临床和影像学结果均较好,KC的ABCD分期系统得到改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Clinical outcomes of two symmetrical Kera-rings implanted in grade three keratoconus: a retrospective nonrandomized study.

Purpose: To evaluate the clinical outcomes of implanting two symmetrical Kerarings via a femtosecond laser in grade three keratoconus.

Patients and methods: This was a retrospective nonrandomized controlled clinical study. The study included one eye from each of twenty-three patients, all with Grade 3 keratoconus as classified by the Amsler-Krumeich classification. The ICRS surgery was performed with the patient under topical anaesthesia (benoxinate hydrochloride 4 mg/mL 0.4%). A tunnel channel was created by a femtosecond laser using a 60-kHz infrared neodymium glass femtosecond laser at a wavelength of 1053 nm (Abbott Laboratories Inc., Abbott Park, Illinois, USA). Two symmetrical Kerarings (Mediphacos Inc., Belo Horizonte, Brazil) were implanted in all the cases with 160° arcs and 250,300 µm thicknesses according to the corneal thickness at the implantation site. After surgery, the patients underwent a full ocular evaluation on Days 1, 7, and 14 and after one month. For a period of 1 year, corneal topography readings were taken quarterly, and the numbers of Pentacam measurements were averaged.

Results: Twenty-three eyes of twenty-three patients were included in this study. The mean value (± SD) of age was 22.8 (± 6.84) years. Six (26.09%) eyes were from males, and 17 (73.91%) were from females. The cone location was central for all patients. Spherical error, cylindrical error, spherical equivalent (SE), uncorrected visual acuity (UCVA), and best corrected visual acuity (BCVA) significantly improved after 3, 6, 9, and 12 months compared with the preoperative values (P value < 0.001). There was no significant difference in the axial and pachymetry readings before and after surgery. Kmax flattened insignificantly at 3 and 6 months of follow-up, whereas significant flattening was achieved at 9 and 12 months (P values = 0.046 and 0.042, respectively). The K mean, K1, K2, anterior elevation, topographic cylinder, and Q value posterior to the corneal surface were significantly lower at the 3-, 6-, 9- and 12-month follow-up visits than preoperatively (P value < 0.05). Posterior elevation and the Q value of the anterior corneal surface were significantly greater after surgery (3, 6, 9, and 12 months) than before surgery (P value < 0.05). With respect to the Belin ABCD grading system, A and D significantly improved throughout the follow-up visits (3, 6, 9, and 12 months) (P value < 0.001), whereas B and C did not significantly differ between the 3-, 6-, 9- and 12-month follow-up visits and the preoperative values.

Conclusion: Grade 3 KC, with the central cone managed with two symmetrical kera-rings, showed favourable results with respect to clinical and topographic outcomes, with improvements in the ABCD staging system of KC.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Ophthalmology
BMC Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
5.00%
发文量
441
审稿时长
6-12 weeks
期刊介绍: BMC Ophthalmology is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of eye disorders, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信