硅藻生物二氧化硅液相色谱。

IF 3.8 2区 化学 Q1 BIOCHEMICAL RESEARCH METHODS
Michał Szumski , Hussam AlSaoud , Izabela Wojtczak , Myroslav Sprynskyy , Renata Gadzała-Kopciuch , Szymon Bocian , Mikołaj Dembek , Marek Potrzebowski , Bogusław Buszewski
{"title":"硅藻生物二氧化硅液相色谱。","authors":"Michał Szumski ,&nbsp;Hussam AlSaoud ,&nbsp;Izabela Wojtczak ,&nbsp;Myroslav Sprynskyy ,&nbsp;Renata Gadzała-Kopciuch ,&nbsp;Szymon Bocian ,&nbsp;Mikołaj Dembek ,&nbsp;Marek Potrzebowski ,&nbsp;Bogusław Buszewski","doi":"10.1016/j.chroma.2024.465603","DOIUrl":null,"url":null,"abstract":"<div><div>This work presents, for the first time, the preparation method and subsequent use of biosilica in column liquid chromatography in reverse-phase mode. Diatom biosilica consists of the siliceous exoskeletons (frustules) of unicellular algae. Controlled cultivation of Pseudostaurosira trainorii diatoms resulted in frustules with an average diameter of approximately 4 µm, sidewall thickness of 1 µm, and a bottom thickness of 110–150 nm. These frustules contained pores (holes) with diameters ranging from 150 to 300 nm. XRD measurements revealed an opal A silica structure, with some lamellar features, and the material was characterized by a surface area of 21.1 m²/g.</div><div>The raw material required careful preparation to remove residual organics by heating it. Following this, the surface was modified with octadecyldimethylchlorosilane to create a reverse-phase chromatographic adsorbent. The resulting columns demonstrated good chromatographic performance, with a theoretical plate number (N) of 22,000 plates for alkylbenzenes on a 160 mm long column, and permeability (K<sub>F</sub>) of 5.33 × 10⁻¹⁵ m².</div><div>The prepared material exhibited lower hydrophobicity compared to the commercially available HALO C18 stationary phase, which can be attributed to its lower surface area and high number of silanol groups. As a result, only partial separation of six polyaromatic hydrocarbons was achieved due to excessive tailing. However, five anti-inflammatory drugs and two veterinary antibiotics were successfully separated.</div></div>","PeriodicalId":347,"journal":{"name":"Journal of Chromatography A","volume":"1741 ","pages":"Article 465603"},"PeriodicalIF":3.8000,"publicationDate":"2025-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diatom biosilica for liquid chromatography\",\"authors\":\"Michał Szumski ,&nbsp;Hussam AlSaoud ,&nbsp;Izabela Wojtczak ,&nbsp;Myroslav Sprynskyy ,&nbsp;Renata Gadzała-Kopciuch ,&nbsp;Szymon Bocian ,&nbsp;Mikołaj Dembek ,&nbsp;Marek Potrzebowski ,&nbsp;Bogusław Buszewski\",\"doi\":\"10.1016/j.chroma.2024.465603\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This work presents, for the first time, the preparation method and subsequent use of biosilica in column liquid chromatography in reverse-phase mode. Diatom biosilica consists of the siliceous exoskeletons (frustules) of unicellular algae. Controlled cultivation of Pseudostaurosira trainorii diatoms resulted in frustules with an average diameter of approximately 4 µm, sidewall thickness of 1 µm, and a bottom thickness of 110–150 nm. These frustules contained pores (holes) with diameters ranging from 150 to 300 nm. XRD measurements revealed an opal A silica structure, with some lamellar features, and the material was characterized by a surface area of 21.1 m²/g.</div><div>The raw material required careful preparation to remove residual organics by heating it. Following this, the surface was modified with octadecyldimethylchlorosilane to create a reverse-phase chromatographic adsorbent. The resulting columns demonstrated good chromatographic performance, with a theoretical plate number (N) of 22,000 plates for alkylbenzenes on a 160 mm long column, and permeability (K<sub>F</sub>) of 5.33 × 10⁻¹⁵ m².</div><div>The prepared material exhibited lower hydrophobicity compared to the commercially available HALO C18 stationary phase, which can be attributed to its lower surface area and high number of silanol groups. As a result, only partial separation of six polyaromatic hydrocarbons was achieved due to excessive tailing. However, five anti-inflammatory drugs and two veterinary antibiotics were successfully separated.</div></div>\",\"PeriodicalId\":347,\"journal\":{\"name\":\"Journal of Chromatography A\",\"volume\":\"1741 \",\"pages\":\"Article 465603\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2025-01-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Chromatography A\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0021967324009762\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography A","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021967324009762","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

本文首次介绍了生物二氧化硅的制备方法及其在反相柱液相色谱中的应用。硅藻生物二氧化硅由单细胞藻类的硅质外骨骼组成。通过对照培养,培养出的硅藻平均直径约为4µm,侧壁厚度为1µm,底部厚度为110 ~ 150 nm。这些结晶体包含直径在150到300纳米之间的孔(孔)。XRD测试结果表明,该材料为蛋白石A型二氧化硅结构,具有一定的层状特征,材料的表面积为21.1 m²/g。原料需要仔细制备,通过加热去除残留的有机物。随后,用十八烷基二甲基氯硅烷对表面进行改性,形成反相色谱吸附剂。所得色谱柱表现出良好的色谱性能,在160毫米长的色谱柱上,烷基苯的理论板数(N)为22,000个板,渗透率(KF)为5.33 × 10⁻¹5m²。与市售的HALO C18固定相相比,制备的材料具有较低的疏水性,这可归因于其较低的表面积和较高的硅烷醇基团数量。结果表明,由于尾矿过多,6种多芳烃只能实现部分分离。但成功分离出5种消炎药和2种兽用抗生素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Diatom biosilica for liquid chromatography
This work presents, for the first time, the preparation method and subsequent use of biosilica in column liquid chromatography in reverse-phase mode. Diatom biosilica consists of the siliceous exoskeletons (frustules) of unicellular algae. Controlled cultivation of Pseudostaurosira trainorii diatoms resulted in frustules with an average diameter of approximately 4 µm, sidewall thickness of 1 µm, and a bottom thickness of 110–150 nm. These frustules contained pores (holes) with diameters ranging from 150 to 300 nm. XRD measurements revealed an opal A silica structure, with some lamellar features, and the material was characterized by a surface area of 21.1 m²/g.
The raw material required careful preparation to remove residual organics by heating it. Following this, the surface was modified with octadecyldimethylchlorosilane to create a reverse-phase chromatographic adsorbent. The resulting columns demonstrated good chromatographic performance, with a theoretical plate number (N) of 22,000 plates for alkylbenzenes on a 160 mm long column, and permeability (KF) of 5.33 × 10⁻¹⁵ m².
The prepared material exhibited lower hydrophobicity compared to the commercially available HALO C18 stationary phase, which can be attributed to its lower surface area and high number of silanol groups. As a result, only partial separation of six polyaromatic hydrocarbons was achieved due to excessive tailing. However, five anti-inflammatory drugs and two veterinary antibiotics were successfully separated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Chromatography A
Journal of Chromatography A 化学-分析化学
CiteScore
7.90
自引率
14.60%
发文量
742
审稿时长
45 days
期刊介绍: The Journal of Chromatography A provides a forum for the publication of original research and critical reviews on all aspects of fundamental and applied separation science. The scope of the journal includes chromatography and related techniques, electromigration techniques (e.g. electrophoresis, electrochromatography), hyphenated and other multi-dimensional techniques, sample preparation, and detection methods such as mass spectrometry. Contributions consist mainly of research papers dealing with the theory of separation methods, instrumental developments and analytical and preparative applications of general interest.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信