视觉和荧光双模式平台对乳腺癌的敏感和准确筛查。

IF 10.7 1区 生物学 Q1 BIOPHYSICS
Biosensors and Bioelectronics Pub Date : 2025-03-01 Epub Date: 2024-12-11 DOI:10.1016/j.bios.2024.117047
Qiongdan Zhang, Qingyi Liu, Kang Long, Kang Zhou, Zheng Yang, Anqi Ge, Jinhui Hu, Caiyun Peng, Wei Wang, Huizhen Wang, Bin Li
{"title":"视觉和荧光双模式平台对乳腺癌的敏感和准确筛查。","authors":"Qiongdan Zhang, Qingyi Liu, Kang Long, Kang Zhou, Zheng Yang, Anqi Ge, Jinhui Hu, Caiyun Peng, Wei Wang, Huizhen Wang, Bin Li","doi":"10.1016/j.bios.2024.117047","DOIUrl":null,"url":null,"abstract":"<p><p>Compared to single-mode detection, dual-mode sensing strategies have garnered increasing attention from researchers due to their superior detection accuracy and reliability. Exosomes, as non-invasive biomarkers, hold significant potential for disease diagnosis. However, sensitive and precise detection of exosomes still presents considerable technical challenges. Inspired by the advantages of dual-mode detection, we developed a visual and fluorescence dual-mode platform (VFDMP) based on an aptamer strategy for exosome detection using enzyme-free nucleic acid amplification and nanomaterial-assisted cation exchange reactions (CERs). The Aptamer-ssDNA complexes capture tumor-derived exosomes, releasing abundant single-stranded DNA (ssDNAs), which then triggers the catalytic hairpin assembly (CHA) cycle, leading to the release of Ag<sup>+</sup>. The introduced CdTe quantum dots (QDs) act as signal reporters, interacting with Ag<sup>+</sup> through CERs, and switching both fluorescence and visual signals from \"on\" to \"off\" to achieve exosome detection. Based on this innovative sensing principle, the developed FL/visual dual-mode aptasensor demonstrated excellent sensitivity and accuracy, achieving a low detection limit of 1.1 particles/μL by fluorometer, while exosome concentrations as low as 300 particles/mL could be visually distinguished by naked eye. Furthermore, this dual-mode platform can directly detect exosomes in clinical human serum samples, with only a small volume (10 μL) required. It can accurately differentiate between healthy individuals and breast cancer patients, as well as identify cancer stages (Stage II and Stage III) and subtypes (triple-negative, luminal B, and HER2+). These results suggest that the developed dual-mode detection strategy holds great promise as a sensitive, accurate method for biomarker analysis in clinical samples.</p>","PeriodicalId":259,"journal":{"name":"Biosensors and Bioelectronics","volume":"271 ","pages":"117047"},"PeriodicalIF":10.7000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Visual and fluorescence dual mode platform for sensitive and accurate screening of breast carcinoma.\",\"authors\":\"Qiongdan Zhang, Qingyi Liu, Kang Long, Kang Zhou, Zheng Yang, Anqi Ge, Jinhui Hu, Caiyun Peng, Wei Wang, Huizhen Wang, Bin Li\",\"doi\":\"10.1016/j.bios.2024.117047\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Compared to single-mode detection, dual-mode sensing strategies have garnered increasing attention from researchers due to their superior detection accuracy and reliability. Exosomes, as non-invasive biomarkers, hold significant potential for disease diagnosis. However, sensitive and precise detection of exosomes still presents considerable technical challenges. Inspired by the advantages of dual-mode detection, we developed a visual and fluorescence dual-mode platform (VFDMP) based on an aptamer strategy for exosome detection using enzyme-free nucleic acid amplification and nanomaterial-assisted cation exchange reactions (CERs). The Aptamer-ssDNA complexes capture tumor-derived exosomes, releasing abundant single-stranded DNA (ssDNAs), which then triggers the catalytic hairpin assembly (CHA) cycle, leading to the release of Ag<sup>+</sup>. The introduced CdTe quantum dots (QDs) act as signal reporters, interacting with Ag<sup>+</sup> through CERs, and switching both fluorescence and visual signals from \\\"on\\\" to \\\"off\\\" to achieve exosome detection. Based on this innovative sensing principle, the developed FL/visual dual-mode aptasensor demonstrated excellent sensitivity and accuracy, achieving a low detection limit of 1.1 particles/μL by fluorometer, while exosome concentrations as low as 300 particles/mL could be visually distinguished by naked eye. Furthermore, this dual-mode platform can directly detect exosomes in clinical human serum samples, with only a small volume (10 μL) required. It can accurately differentiate between healthy individuals and breast cancer patients, as well as identify cancer stages (Stage II and Stage III) and subtypes (triple-negative, luminal B, and HER2+). These results suggest that the developed dual-mode detection strategy holds great promise as a sensitive, accurate method for biomarker analysis in clinical samples.</p>\",\"PeriodicalId\":259,\"journal\":{\"name\":\"Biosensors and Bioelectronics\",\"volume\":\"271 \",\"pages\":\"117047\"},\"PeriodicalIF\":10.7000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors and Bioelectronics\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://doi.org/10.1016/j.bios.2024.117047\",\"RegionNum\":1,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics","FirstCategoryId":"1","ListUrlMain":"https://doi.org/10.1016/j.bios.2024.117047","RegionNum":1,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/11 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

与单模检测相比,双模检测策略由于具有更高的检测精度和可靠性而越来越受到研究人员的关注。外泌体作为非侵入性生物标志物,在疾病诊断中具有重要的潜力。然而,灵敏和精确地检测外泌体仍然存在相当大的技术挑战。受双模检测优势的启发,我们基于适体策略开发了一种基于无酶核酸扩增和纳米材料辅助阳离子交换反应(CERs)的外泌体检测的视觉和荧光双模平台(VFDMP)。Aptamer-ssDNA复合物捕获肿瘤衍生的外泌体,释放大量单链DNA (ssdna),然后触发催化发夹组装(CHA)循环,导致Ag+的释放。引入的CdTe量子点(QDs)作为信号报告者,通过cer与Ag+相互作用,并将荧光和视觉信号从“开”切换到“关”,以实现外泌体检测。基于这一创新的传感原理,所开发的FL/visual双模配体传感器具有良好的灵敏度和准确性,荧光仪检测限低至1.1个颗粒/μL,而外泌体浓度低至300个颗粒/mL即可通过肉眼视觉区分。此外,该双模式平台可直接检测临床人血清样品中的外泌体,只需要小体积(10 μL)。它可以准确区分健康个体和乳腺癌患者,并识别癌症分期(II期和III期)和亚型(三阴性、luminal B和HER2+)。这些结果表明,所开发的双模式检测策略作为一种敏感、准确的临床样品生物标志物分析方法具有很大的前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Visual and fluorescence dual mode platform for sensitive and accurate screening of breast carcinoma.

Compared to single-mode detection, dual-mode sensing strategies have garnered increasing attention from researchers due to their superior detection accuracy and reliability. Exosomes, as non-invasive biomarkers, hold significant potential for disease diagnosis. However, sensitive and precise detection of exosomes still presents considerable technical challenges. Inspired by the advantages of dual-mode detection, we developed a visual and fluorescence dual-mode platform (VFDMP) based on an aptamer strategy for exosome detection using enzyme-free nucleic acid amplification and nanomaterial-assisted cation exchange reactions (CERs). The Aptamer-ssDNA complexes capture tumor-derived exosomes, releasing abundant single-stranded DNA (ssDNAs), which then triggers the catalytic hairpin assembly (CHA) cycle, leading to the release of Ag+. The introduced CdTe quantum dots (QDs) act as signal reporters, interacting with Ag+ through CERs, and switching both fluorescence and visual signals from "on" to "off" to achieve exosome detection. Based on this innovative sensing principle, the developed FL/visual dual-mode aptasensor demonstrated excellent sensitivity and accuracy, achieving a low detection limit of 1.1 particles/μL by fluorometer, while exosome concentrations as low as 300 particles/mL could be visually distinguished by naked eye. Furthermore, this dual-mode platform can directly detect exosomes in clinical human serum samples, with only a small volume (10 μL) required. It can accurately differentiate between healthy individuals and breast cancer patients, as well as identify cancer stages (Stage II and Stage III) and subtypes (triple-negative, luminal B, and HER2+). These results suggest that the developed dual-mode detection strategy holds great promise as a sensitive, accurate method for biomarker analysis in clinical samples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biosensors and Bioelectronics
Biosensors and Bioelectronics 工程技术-电化学
CiteScore
20.80
自引率
7.10%
发文量
1006
审稿时长
29 days
期刊介绍: Biosensors & Bioelectronics, along with its open access companion journal Biosensors & Bioelectronics: X, is the leading international publication in the field of biosensors and bioelectronics. It covers research, design, development, and application of biosensors, which are analytical devices incorporating biological materials with physicochemical transducers. These devices, including sensors, DNA chips, electronic noses, and lab-on-a-chip, produce digital signals proportional to specific analytes. Examples include immunosensors and enzyme-based biosensors, applied in various fields such as medicine, environmental monitoring, and food industry. The journal also focuses on molecular and supramolecular structures for enhancing device performance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信