加强变压器绕组监测:使用纵向支路电导分析的方法

IF 2 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
Xiangping Kong, Zijun Bin, Jiansheng Li, Shiming Liu, Wenchen Zhao, Mengfei Wu
{"title":"加强变压器绕组监测:使用纵向支路电导分析的方法","authors":"Xiangping Kong,&nbsp;Zijun Bin,&nbsp;Jiansheng Li,&nbsp;Shiming Liu,&nbsp;Wenchen Zhao,&nbsp;Mengfei Wu","doi":"10.1049/gtd2.13342","DOIUrl":null,"url":null,"abstract":"<p>The operating environment of transformers is getting more complex with the emergence of new energy sources and power electronic devices. This complexity can cause minor internal faults in transformer windings. Under the cumulative effect, minor faults gradually develop into serious faults, resulting in transformer damage. Conventional differential protection systems may have difficulty detecting these glitches and require avoiding the problem of protection false activation caused by inrush currents. This paper proposes a new online monitoring method for transformer windings based on longitudinal branch-circuit conductance to address this issue. First, a unified transformer equivalent circuit is proposed to represent transformers under normal conditions, inrush currents, and internal faults. Then, an online transformer monitoring method based on branch conductance is proposed, which is immune to inrush currents. This method aims to prevent delayed detection of faults during inrush currents, improving sensitivity and response speed, especially for minor turn-to-turn faults hidden in inrush currents. The proposed method also provides higher sensitivity to minor turn-to-turn faults and larger protection margins. Simulation and experimental results validate the effectiveness of this method.</p>","PeriodicalId":13261,"journal":{"name":"Iet Generation Transmission & Distribution","volume":"18 24","pages":"4358-4368"},"PeriodicalIF":2.0000,"publicationDate":"2024-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13342","citationCount":"0","resultStr":"{\"title\":\"Enhancing transformer windings monitoring: An approach using longitudinal branch-circuit conductance analysis\",\"authors\":\"Xiangping Kong,&nbsp;Zijun Bin,&nbsp;Jiansheng Li,&nbsp;Shiming Liu,&nbsp;Wenchen Zhao,&nbsp;Mengfei Wu\",\"doi\":\"10.1049/gtd2.13342\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The operating environment of transformers is getting more complex with the emergence of new energy sources and power electronic devices. This complexity can cause minor internal faults in transformer windings. Under the cumulative effect, minor faults gradually develop into serious faults, resulting in transformer damage. Conventional differential protection systems may have difficulty detecting these glitches and require avoiding the problem of protection false activation caused by inrush currents. This paper proposes a new online monitoring method for transformer windings based on longitudinal branch-circuit conductance to address this issue. First, a unified transformer equivalent circuit is proposed to represent transformers under normal conditions, inrush currents, and internal faults. Then, an online transformer monitoring method based on branch conductance is proposed, which is immune to inrush currents. This method aims to prevent delayed detection of faults during inrush currents, improving sensitivity and response speed, especially for minor turn-to-turn faults hidden in inrush currents. The proposed method also provides higher sensitivity to minor turn-to-turn faults and larger protection margins. Simulation and experimental results validate the effectiveness of this method.</p>\",\"PeriodicalId\":13261,\"journal\":{\"name\":\"Iet Generation Transmission & Distribution\",\"volume\":\"18 24\",\"pages\":\"4358-4368\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-12-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13342\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iet Generation Transmission & Distribution\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13342\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Generation Transmission & Distribution","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13342","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

随着新能源和电力电子设备的出现,变压器的运行环境变得越来越复杂。这种复杂性会导致变压器绕组出现轻微的内部故障。在累积作用下,小故障逐渐发展为严重故障,造成变压器损坏。传统的差动保护系统可能难以检测这些故障,并且需要避免由涌流引起的保护误激活问题。针对这一问题,本文提出了一种基于纵向支路电导的变压器绕组在线监测新方法。首先,提出了一个统一的变压器等效电路来表示变压器在正常状态、涌流和内部故障情况下的等效电路。在此基础上,提出了一种不受冲击电流影响的基于支路电导的变压器在线监测方法。该方法旨在防止在涌流过程中故障的延迟检测,提高灵敏度和响应速度,特别是对于隐藏在涌流中的小匝间故障。该方法对小匝间故障具有较高的灵敏度和较大的保护裕量。仿真和实验结果验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Enhancing transformer windings monitoring: An approach using longitudinal branch-circuit conductance analysis

Enhancing transformer windings monitoring: An approach using longitudinal branch-circuit conductance analysis

The operating environment of transformers is getting more complex with the emergence of new energy sources and power electronic devices. This complexity can cause minor internal faults in transformer windings. Under the cumulative effect, minor faults gradually develop into serious faults, resulting in transformer damage. Conventional differential protection systems may have difficulty detecting these glitches and require avoiding the problem of protection false activation caused by inrush currents. This paper proposes a new online monitoring method for transformer windings based on longitudinal branch-circuit conductance to address this issue. First, a unified transformer equivalent circuit is proposed to represent transformers under normal conditions, inrush currents, and internal faults. Then, an online transformer monitoring method based on branch conductance is proposed, which is immune to inrush currents. This method aims to prevent delayed detection of faults during inrush currents, improving sensitivity and response speed, especially for minor turn-to-turn faults hidden in inrush currents. The proposed method also provides higher sensitivity to minor turn-to-turn faults and larger protection margins. Simulation and experimental results validate the effectiveness of this method.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Iet Generation Transmission & Distribution
Iet Generation Transmission & Distribution 工程技术-工程:电子与电气
CiteScore
6.10
自引率
12.00%
发文量
301
审稿时长
5.4 months
期刊介绍: IET Generation, Transmission & Distribution is intended as a forum for the publication and discussion of current practice and future developments in electric power generation, transmission and distribution. Practical papers in which examples of good present practice can be described and disseminated are particularly sought. Papers of high technical merit relying on mathematical arguments and computation will be considered, but authors are asked to relegate, as far as possible, the details of analysis to an appendix. The scope of IET Generation, Transmission & Distribution includes the following: Design of transmission and distribution systems Operation and control of power generation Power system management, planning and economics Power system operation, protection and control Power system measurement and modelling Computer applications and computational intelligence in power flexible AC or DC transmission systems Special Issues. Current Call for papers: Next Generation of Synchrophasor-based Power System Monitoring, Operation and Control - https://digital-library.theiet.org/files/IET_GTD_CFP_NGSPSMOC.pdf
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信