白内障手术后单焦点人工晶状体的视力质量:综合评价和图解。

IF 1.4 4区 医学 Q3 OPHTHALMOLOGY
Jorge Fs Henriques, Marisa A Duarte, Tatiana Sm Queirós, Rita Coimbra, Francisco Caramelo, Andreia Fm Rosa, Conceição L Lobo Fonseca, Joaquim Cn Murta
{"title":"白内障手术后单焦点人工晶状体的视力质量:综合评价和图解。","authors":"Jorge Fs Henriques, Marisa A Duarte, Tatiana Sm Queirós, Rita Coimbra, Francisco Caramelo, Andreia Fm Rosa, Conceição L Lobo Fonseca, Joaquim Cn Murta","doi":"10.1177/11206721241306156","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To comprehensively characterize the quality of vision (QV) in an otherwise healthy population undergoing bilateral consecutive cataract surgery with the implantation of a monofocal intraocular lens (IOL) and to propose a graphical illustration.</p><p><strong>Setting: </strong><i>Centro Hospitalar e Universitário de Coimbra</i>, Portugal.</p><p><strong>Design: </strong>Cross-sectional study.</p><p><strong>Methods: </strong>This study included patients that underwent sequential bilateral cataract surgery with implantation of a monofocal acrylic foldable single-piece IOL. Patients were evaluated at the 3rd postoperative month in terms of bilateral uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA) and corrected near visual acuity (CNVA); sphero-cylindrical refraction; bilateral reading speed and contrast sensitivity function (CSF); corneal topography/tomography; aberrometry; pupillometry; negative dysphotopsia (ND); Catquest-9SF and Quality of Vision (QoV) questionnaires.</p><p><strong>Results: </strong>Both eyes from 26 (n = 26) consecutive patients with mean age of 68 years ± 6.68 were included. UDVA mean was logMAR = 0.01 ± 0.04, and CDVA was logMAR = 0.00 ± 0.04. The average reading speed was 110.42 words/minute. The CSF showed a descendent curve for higher spatial frequencies and was lower with glare. ND was present in 1.92% of the patients. Catquest-9SF mean was 95.46% and QoV mean score was 4.48 points. A radar graph showing median scores across the multiple variables assessed was produced demonstrating a wide panorama of QV.</p><p><strong>Conclusion: </strong>Patients' satisfaction was correlated with CSF, reading speed, CNVA and residual spherical equivalent. To the author's best knowledge, this study establishes, for the first time, a comprehensive panorama of visual performance through a radar graph that can be utilized to describe the QV.</p>","PeriodicalId":12000,"journal":{"name":"European Journal of Ophthalmology","volume":" ","pages":"11206721241306156"},"PeriodicalIF":1.4000,"publicationDate":"2024-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quality of vision with monofocal intraocular lens after cataract surgery: Comprehensive evaluation and graphical illustration.\",\"authors\":\"Jorge Fs Henriques, Marisa A Duarte, Tatiana Sm Queirós, Rita Coimbra, Francisco Caramelo, Andreia Fm Rosa, Conceição L Lobo Fonseca, Joaquim Cn Murta\",\"doi\":\"10.1177/11206721241306156\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To comprehensively characterize the quality of vision (QV) in an otherwise healthy population undergoing bilateral consecutive cataract surgery with the implantation of a monofocal intraocular lens (IOL) and to propose a graphical illustration.</p><p><strong>Setting: </strong><i>Centro Hospitalar e Universitário de Coimbra</i>, Portugal.</p><p><strong>Design: </strong>Cross-sectional study.</p><p><strong>Methods: </strong>This study included patients that underwent sequential bilateral cataract surgery with implantation of a monofocal acrylic foldable single-piece IOL. Patients were evaluated at the 3rd postoperative month in terms of bilateral uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA) and corrected near visual acuity (CNVA); sphero-cylindrical refraction; bilateral reading speed and contrast sensitivity function (CSF); corneal topography/tomography; aberrometry; pupillometry; negative dysphotopsia (ND); Catquest-9SF and Quality of Vision (QoV) questionnaires.</p><p><strong>Results: </strong>Both eyes from 26 (n = 26) consecutive patients with mean age of 68 years ± 6.68 were included. UDVA mean was logMAR = 0.01 ± 0.04, and CDVA was logMAR = 0.00 ± 0.04. The average reading speed was 110.42 words/minute. The CSF showed a descendent curve for higher spatial frequencies and was lower with glare. ND was present in 1.92% of the patients. Catquest-9SF mean was 95.46% and QoV mean score was 4.48 points. A radar graph showing median scores across the multiple variables assessed was produced demonstrating a wide panorama of QV.</p><p><strong>Conclusion: </strong>Patients' satisfaction was correlated with CSF, reading speed, CNVA and residual spherical equivalent. To the author's best knowledge, this study establishes, for the first time, a comprehensive panorama of visual performance through a radar graph that can be utilized to describe the QV.</p>\",\"PeriodicalId\":12000,\"journal\":{\"name\":\"European Journal of Ophthalmology\",\"volume\":\" \",\"pages\":\"11206721241306156\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-12-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11206721241306156\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11206721241306156","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:综合描述双侧连续白内障手术并植入单焦点人工晶状体(IOL)的健康人群的视力质量(QV),并提出图形说明。地点:葡萄牙科英布拉中心医院Universitário。设计:横断面研究。方法:本研究纳入了行序贯双侧白内障手术并植入单焦点丙烯酸可折叠单片人工晶状体的患者。术后第3个月评估患者双侧未矫正距离视力(UDVA)、矫正距离视力(CDVA)和矫正近视力(CNVA);sphero-cylindrical折射;双边阅读速度和对比灵敏度功能(CSF);角膜地形/断层;aberrometry;瞳孔测量法;阴性呼吸障碍(ND);Catquest-9SF和视觉质量(QoV)问卷。结果:纳入26例(n = 26)连续患者的双眼,平均年龄为68岁±6.68岁。UDVA平均值logMAR = 0.01±0.04,CDVA平均值logMAR = 0.00±0.04。平均阅读速度为110.42字/分。脑脊液在高空间频率下呈下降曲线,在强光下呈下降曲线。1.92%的患者存在ND。Catquest-9SF平均值为95.46%,QoV平均值为4.48分。雷达图显示了评估的多个变量的中位数得分,展示了QV的广阔全景。结论:患者满意度与脑脊液、阅读速度、CNVA和剩余球当量相关。据作者所知,本研究首次通过可用于描述QV的雷达图建立了视觉表现的全面全景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Quality of vision with monofocal intraocular lens after cataract surgery: Comprehensive evaluation and graphical illustration.

Purpose: To comprehensively characterize the quality of vision (QV) in an otherwise healthy population undergoing bilateral consecutive cataract surgery with the implantation of a monofocal intraocular lens (IOL) and to propose a graphical illustration.

Setting: Centro Hospitalar e Universitário de Coimbra, Portugal.

Design: Cross-sectional study.

Methods: This study included patients that underwent sequential bilateral cataract surgery with implantation of a monofocal acrylic foldable single-piece IOL. Patients were evaluated at the 3rd postoperative month in terms of bilateral uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA) and corrected near visual acuity (CNVA); sphero-cylindrical refraction; bilateral reading speed and contrast sensitivity function (CSF); corneal topography/tomography; aberrometry; pupillometry; negative dysphotopsia (ND); Catquest-9SF and Quality of Vision (QoV) questionnaires.

Results: Both eyes from 26 (n = 26) consecutive patients with mean age of 68 years ± 6.68 were included. UDVA mean was logMAR = 0.01 ± 0.04, and CDVA was logMAR = 0.00 ± 0.04. The average reading speed was 110.42 words/minute. The CSF showed a descendent curve for higher spatial frequencies and was lower with glare. ND was present in 1.92% of the patients. Catquest-9SF mean was 95.46% and QoV mean score was 4.48 points. A radar graph showing median scores across the multiple variables assessed was produced demonstrating a wide panorama of QV.

Conclusion: Patients' satisfaction was correlated with CSF, reading speed, CNVA and residual spherical equivalent. To the author's best knowledge, this study establishes, for the first time, a comprehensive panorama of visual performance through a radar graph that can be utilized to describe the QV.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
0.00%
发文量
372
审稿时长
3-8 weeks
期刊介绍: The European Journal of Ophthalmology was founded in 1991 and is issued in print bi-monthly. It publishes only peer-reviewed original research reporting clinical observations and laboratory investigations with clinical relevance focusing on new diagnostic and surgical techniques, instrument and therapy updates, results of clinical trials and research findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信