一个全面的物理信息的神经网络解决方案,用于乳腺肿瘤的精确破坏使用聚焦超声在一个现实的乳房模型。

IF 2.6 4区 工程技术 Q1 Mathematics
Salman Lari, Hossein Rajabzadeh, Mohammad Kohandel, Hyock Ju Kwon
{"title":"一个全面的物理信息的神经网络解决方案,用于乳腺肿瘤的精确破坏使用聚焦超声在一个现实的乳房模型。","authors":"Salman Lari, Hossein Rajabzadeh, Mohammad Kohandel, Hyock Ju Kwon","doi":"10.3934/mbe.2024323","DOIUrl":null,"url":null,"abstract":"<p><p>This study presented a novel approach for the precise ablation of breast tumors using focused ultrasound (FUS), leveraging a physics-informed neural network (PINN) integrated with a realistic breast model. FUS has shown significant promise in treating breast tumors by effectively targeting and ablating cancerous tissue. This technique employs concentrated ultrasonic waves to generate intense heat, effectively destroying cancerous tissue. In previous finite element method (FEM) models, the computational demands of handling extensive datasets, multiple dimensions, and discretization posed significant challenges. Our PINN-based solution operated efficiently in a mesh-free domain, achieving remarkable accuracy with significantly reduced computational demands, compared to conventional FEM techniques. Additionally, employing PINN for estimating partial differential equations (PDE) solutions can notably decrease the enormous number of discretized elements needed. The model employed a bowl-shaped acoustic transducer to focus ultrasound waves accurately on the tumor location. The simulation results offered detailed insights into each step of the FUS treatment process, including the generation of acoustic waves, the targeting of the tumor, and the subsequent heating and ablation of cancerous tissue. By applying a 3.8 nm displacement amplitude of transducer input pulse at a frequency of 1.1 MHz for 1 second, the temperature at the focal point elevated to 38.4 ℃, followed by another 90 seconds of cooling time, which resulted in significant necrosis of the tumor tissues. Validation of the PINN model's accuracy was conducted through FEM analysis, aligning closely with real-world FUS therapy scenarios. This innovative model provided physicians with a predictive tool to estimate the necrosis of tumor tissue, facilitating the customization of FUS treatment strategies for individual breast cancer patients.</p>","PeriodicalId":49870,"journal":{"name":"Mathematical Biosciences and Engineering","volume":"21 10","pages":"7337-7372"},"PeriodicalIF":2.6000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A holistic physics-informed neural network solution for precise destruction of breast tumors using focused ultrasound on a realistic breast model.\",\"authors\":\"Salman Lari, Hossein Rajabzadeh, Mohammad Kohandel, Hyock Ju Kwon\",\"doi\":\"10.3934/mbe.2024323\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study presented a novel approach for the precise ablation of breast tumors using focused ultrasound (FUS), leveraging a physics-informed neural network (PINN) integrated with a realistic breast model. FUS has shown significant promise in treating breast tumors by effectively targeting and ablating cancerous tissue. This technique employs concentrated ultrasonic waves to generate intense heat, effectively destroying cancerous tissue. In previous finite element method (FEM) models, the computational demands of handling extensive datasets, multiple dimensions, and discretization posed significant challenges. Our PINN-based solution operated efficiently in a mesh-free domain, achieving remarkable accuracy with significantly reduced computational demands, compared to conventional FEM techniques. Additionally, employing PINN for estimating partial differential equations (PDE) solutions can notably decrease the enormous number of discretized elements needed. The model employed a bowl-shaped acoustic transducer to focus ultrasound waves accurately on the tumor location. The simulation results offered detailed insights into each step of the FUS treatment process, including the generation of acoustic waves, the targeting of the tumor, and the subsequent heating and ablation of cancerous tissue. By applying a 3.8 nm displacement amplitude of transducer input pulse at a frequency of 1.1 MHz for 1 second, the temperature at the focal point elevated to 38.4 ℃, followed by another 90 seconds of cooling time, which resulted in significant necrosis of the tumor tissues. Validation of the PINN model's accuracy was conducted through FEM analysis, aligning closely with real-world FUS therapy scenarios. This innovative model provided physicians with a predictive tool to estimate the necrosis of tumor tissue, facilitating the customization of FUS treatment strategies for individual breast cancer patients.</p>\",\"PeriodicalId\":49870,\"journal\":{\"name\":\"Mathematical Biosciences and Engineering\",\"volume\":\"21 10\",\"pages\":\"7337-7372\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mathematical Biosciences and Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3934/mbe.2024323\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Mathematics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mathematical Biosciences and Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3934/mbe.2024323","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Mathematics","Score":null,"Total":0}
引用次数: 0

摘要

本研究提出了一种利用聚焦超声(FUS)精确消融乳腺肿瘤的新方法,利用物理信息神经网络(PINN)与真实乳房模型相结合。FUS通过有效靶向和消融癌组织在治疗乳腺肿瘤方面显示出显著的前景。这种技术利用集中的超声波产生强烈的热量,有效地破坏癌组织。在以往的有限元模型中,处理大量数据集、多维度和离散化的计算需求带来了巨大的挑战。与传统的FEM技术相比,我们基于ppin的解决方案在无网格域内高效运行,在显著降低计算量的同时获得了显著的精度。此外,使用PINN来估计偏微分方程(PDE)解可以显著减少所需的大量离散元素。该模型采用碗形声换能器将超声准确聚焦于肿瘤位置。模拟结果为FUS治疗过程的每个步骤提供了详细的见解,包括声波的产生、肿瘤的靶向以及随后对癌组织的加热和消融。在1.1 MHz频率下施加位移幅度为3.8 nm的换能器输入脉冲1秒,使焦点温度升高至38.4℃,再冷却90秒,导致肿瘤组织明显坏死。通过FEM分析验证了PINN模型的准确性,与真实的FUS治疗场景密切相关。这一创新模型为医生提供了一种预测肿瘤组织坏死的工具,便于为乳腺癌患者个性化定制FUS治疗策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A holistic physics-informed neural network solution for precise destruction of breast tumors using focused ultrasound on a realistic breast model.

This study presented a novel approach for the precise ablation of breast tumors using focused ultrasound (FUS), leveraging a physics-informed neural network (PINN) integrated with a realistic breast model. FUS has shown significant promise in treating breast tumors by effectively targeting and ablating cancerous tissue. This technique employs concentrated ultrasonic waves to generate intense heat, effectively destroying cancerous tissue. In previous finite element method (FEM) models, the computational demands of handling extensive datasets, multiple dimensions, and discretization posed significant challenges. Our PINN-based solution operated efficiently in a mesh-free domain, achieving remarkable accuracy with significantly reduced computational demands, compared to conventional FEM techniques. Additionally, employing PINN for estimating partial differential equations (PDE) solutions can notably decrease the enormous number of discretized elements needed. The model employed a bowl-shaped acoustic transducer to focus ultrasound waves accurately on the tumor location. The simulation results offered detailed insights into each step of the FUS treatment process, including the generation of acoustic waves, the targeting of the tumor, and the subsequent heating and ablation of cancerous tissue. By applying a 3.8 nm displacement amplitude of transducer input pulse at a frequency of 1.1 MHz for 1 second, the temperature at the focal point elevated to 38.4 ℃, followed by another 90 seconds of cooling time, which resulted in significant necrosis of the tumor tissues. Validation of the PINN model's accuracy was conducted through FEM analysis, aligning closely with real-world FUS therapy scenarios. This innovative model provided physicians with a predictive tool to estimate the necrosis of tumor tissue, facilitating the customization of FUS treatment strategies for individual breast cancer patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Mathematical Biosciences and Engineering
Mathematical Biosciences and Engineering 工程技术-数学跨学科应用
CiteScore
3.90
自引率
7.70%
发文量
586
审稿时长
>12 weeks
期刊介绍: Mathematical Biosciences and Engineering (MBE) is an interdisciplinary Open Access journal promoting cutting-edge research, technology transfer and knowledge translation about complex data and information processing. MBE publishes Research articles (long and original research); Communications (short and novel research); Expository papers; Technology Transfer and Knowledge Translation reports (description of new technologies and products); Announcements and Industrial Progress and News (announcements and even advertisement, including major conferences).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信