{"title":"Enhancing Amperometric Ozone Gas Sensing with Room-Temperature Ionic Liquids and Platinum-Based Electrodes","authors":"Huihui Zhang, Hsiang-Wei Yang, Chen-Wei Liu, Cheng Han, Kuan-Wen Wang, Sheng Dai","doi":"10.1021/acsami.4c18003","DOIUrl":null,"url":null,"abstract":"Ozone (O<sub>3</sub>) poses serious health risks, prompting numerous countries to implement regulations that establish exposure limits and emission controls, for example, the air quality index (AQI) for O<sub>3</sub> ranging from 50 to 150 parts per billion (ppb), with natural levels at around 30 ppb. Electrochemical sensors are favored for detecting pollutant gases due to their high sensitivity, low cost, portability, energy efficiency, and capability for selective detection. In this study, we developed an O<sub>3</sub> sensor employing carbon-supported Pt-based binary and ternary nanorods (NRs) combined with room-temperature ionic liquids (RTILs) as electrolytes, aiming at highly sensitive and selective detection of O<sub>3</sub> at ppb levels. Initial screening of the O<sub>3</sub> sensing performance across different electrolytes identified H<sub>2</sub>SO<sub>4</sub> and [C<sub>4</sub>mpyrr][NTf<sub>2</sub>] (BMP) as the most sensitive options. BMP outperformed H<sub>2</sub>SO<sub>4</sub> in terms of linearity, selectivity, reproducibility, and response/recovery times, despite a relatively lower sensitivity. Electrochemical testing of Pt, PtAu, PtAg, and PtAuAg NR electrodes in BMP revealed that the addition of Au enhanced the linear response, while Ag improved sensitivity. Consequently, the ternary PtAuAg NR electrode exhibited the highest sensitivity (10.5 nA/ppm (parts per million)) and a broad detection range, fulfilling the AQI requirements for O<sub>3</sub>. The current response from the PtAuAg NR electrode closely aligned with results from an ultraviolet (UV) photometric analyzer, confirming its accuracy. Notably, this electrode contains only 20 wt % noble metals, which reduces the overall cost to just 11% of that of a traditional pure Au electrode.","PeriodicalId":5,"journal":{"name":"ACS Applied Materials & Interfaces","volume":"28 1","pages":""},"PeriodicalIF":8.3000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Materials & Interfaces","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1021/acsami.4c18003","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
Enhancing Amperometric Ozone Gas Sensing with Room-Temperature Ionic Liquids and Platinum-Based Electrodes
Ozone (O3) poses serious health risks, prompting numerous countries to implement regulations that establish exposure limits and emission controls, for example, the air quality index (AQI) for O3 ranging from 50 to 150 parts per billion (ppb), with natural levels at around 30 ppb. Electrochemical sensors are favored for detecting pollutant gases due to their high sensitivity, low cost, portability, energy efficiency, and capability for selective detection. In this study, we developed an O3 sensor employing carbon-supported Pt-based binary and ternary nanorods (NRs) combined with room-temperature ionic liquids (RTILs) as electrolytes, aiming at highly sensitive and selective detection of O3 at ppb levels. Initial screening of the O3 sensing performance across different electrolytes identified H2SO4 and [C4mpyrr][NTf2] (BMP) as the most sensitive options. BMP outperformed H2SO4 in terms of linearity, selectivity, reproducibility, and response/recovery times, despite a relatively lower sensitivity. Electrochemical testing of Pt, PtAu, PtAg, and PtAuAg NR electrodes in BMP revealed that the addition of Au enhanced the linear response, while Ag improved sensitivity. Consequently, the ternary PtAuAg NR electrode exhibited the highest sensitivity (10.5 nA/ppm (parts per million)) and a broad detection range, fulfilling the AQI requirements for O3. The current response from the PtAuAg NR electrode closely aligned with results from an ultraviolet (UV) photometric analyzer, confirming its accuracy. Notably, this electrode contains only 20 wt % noble metals, which reduces the overall cost to just 11% of that of a traditional pure Au electrode.
期刊介绍:
ACS Applied Materials & Interfaces is a leading interdisciplinary journal that brings together chemists, engineers, physicists, and biologists to explore the development and utilization of newly-discovered materials and interfacial processes for specific applications. Our journal has experienced remarkable growth since its establishment in 2009, both in terms of the number of articles published and the impact of the research showcased. We are proud to foster a truly global community, with the majority of published articles originating from outside the United States, reflecting the rapid growth of applied research worldwide.