{"title":"利用可穿戴设备筛查中度至重度阻塞性睡眠呼吸暂停。","authors":"James Tisyakorn, Narongkorn Saiphoklang, Tunlanut Sapankaew, Kristina Thapa, Chutiporn Anutariya, Aekavute Sujarae, Chatkarin Tepwimonpetkun","doi":"10.1007/s11325-024-03232-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Obstructive sleep apnea (OSA) is a highly prevalent sleep-related breathing disorder usually diagnosed through polysomnography (PSG). Moderate to severe OSA can significantly increase morbidity and mortality. Existing screening tools have limited accuracy. This study aimed to evaluate the Wellue O<sub>2</sub> ring, a commercial pulse oximeter ring, for screening moderate to severe OSA.</p><p><strong>Methods: </strong>A cross-sectional study included adults aged 18 and older suspected of having OSA who underwent PSG while wearing the Wellue O2 ring on their thumb. The oxygen desaturation index (ODI) from both the O2 ring and PSG was recorded. Sensitivity, specificity, and receiver operating characteristic (ROC) curves were calculated to determine the optimal ODI cutoff value for predicting moderate to severe OSA.</p><p><strong>Results: </strong>The study included 190 participants (53.2% male) with an average age of 43 years and an average apnea-hypopnea index (AHI) of 50.4 events per hour. Among the participants, 84.7% had moderate to severe OSA. The optimal cutoff value for 11% ODI was 1.25 events per hour lasting 20 s, with a sensitivity of 87.30% and a specificity of 78.70%. The area under the ROC curve for identifying moderate to severe OSA was 0.91.</p><p><strong>Conclusions: </strong>The Wellue O2 ring demonstrated high accuracy in detecting moderate to severe OSA and could be a viable alternative for screening in clinical settings due to its accessibility and ease of use. However, larger studies are required to validate its clinical utility for diagnosing and managing moderate to severe OSA.</p>","PeriodicalId":21862,"journal":{"name":"Sleep and Breathing","volume":"29 1","pages":"61"},"PeriodicalIF":2.1000,"publicationDate":"2024-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Screening moderate to severe obstructive sleep apnea with wearable device.\",\"authors\":\"James Tisyakorn, Narongkorn Saiphoklang, Tunlanut Sapankaew, Kristina Thapa, Chutiporn Anutariya, Aekavute Sujarae, Chatkarin Tepwimonpetkun\",\"doi\":\"10.1007/s11325-024-03232-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Obstructive sleep apnea (OSA) is a highly prevalent sleep-related breathing disorder usually diagnosed through polysomnography (PSG). Moderate to severe OSA can significantly increase morbidity and mortality. Existing screening tools have limited accuracy. This study aimed to evaluate the Wellue O<sub>2</sub> ring, a commercial pulse oximeter ring, for screening moderate to severe OSA.</p><p><strong>Methods: </strong>A cross-sectional study included adults aged 18 and older suspected of having OSA who underwent PSG while wearing the Wellue O2 ring on their thumb. The oxygen desaturation index (ODI) from both the O2 ring and PSG was recorded. Sensitivity, specificity, and receiver operating characteristic (ROC) curves were calculated to determine the optimal ODI cutoff value for predicting moderate to severe OSA.</p><p><strong>Results: </strong>The study included 190 participants (53.2% male) with an average age of 43 years and an average apnea-hypopnea index (AHI) of 50.4 events per hour. Among the participants, 84.7% had moderate to severe OSA. The optimal cutoff value for 11% ODI was 1.25 events per hour lasting 20 s, with a sensitivity of 87.30% and a specificity of 78.70%. The area under the ROC curve for identifying moderate to severe OSA was 0.91.</p><p><strong>Conclusions: </strong>The Wellue O2 ring demonstrated high accuracy in detecting moderate to severe OSA and could be a viable alternative for screening in clinical settings due to its accessibility and ease of use. However, larger studies are required to validate its clinical utility for diagnosing and managing moderate to severe OSA.</p>\",\"PeriodicalId\":21862,\"journal\":{\"name\":\"Sleep and Breathing\",\"volume\":\"29 1\",\"pages\":\"61\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-12-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sleep and Breathing\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11325-024-03232-9\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sleep and Breathing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11325-024-03232-9","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
摘要
背景:阻塞性睡眠呼吸暂停(OSA)是一种高发的睡眠相关呼吸障碍,通常通过多导睡眠图(PSG)进行诊断。中度到重度 OSA 会大大增加发病率和死亡率。现有筛查工具的准确性有限。本研究旨在评估用于筛查中重度 OSA 的商用脉搏血氧仪 Wellue O2 环:这项横断面研究纳入了 18 岁及以上疑似 OSA 的成年人,他们在拇指上佩戴 Wellue O2 环的同时接受了 PSG 检查。氧饱和度指数(ODI)由氧气环和 PSG 共同记录。计算灵敏度、特异性和接收器操作特征曲线(ROC),以确定预测中度至重度 OSA 的最佳 ODI 临界值:研究包括 190 名参与者(53.2% 为男性),平均年龄为 43 岁,平均呼吸暂停-低通气指数(AHI)为每小时 50.4 次。其中 84.7% 患有中度至重度 OSA。11% ODI 的最佳临界值为每小时 1.25 次,持续 20 秒,灵敏度为 87.30%,特异度为 78.70%。识别中重度 OSA 的 ROC 曲线下面积为 0.91:Wellue 氧气环在检测中度至重度 OSA 方面表现出很高的准确性,由于其易得性和易用性,可作为临床筛查的一种可行替代方法。不过,还需要更大规模的研究来验证它在诊断和管理中重度 OSA 方面的临床实用性。
Screening moderate to severe obstructive sleep apnea with wearable device.
Background: Obstructive sleep apnea (OSA) is a highly prevalent sleep-related breathing disorder usually diagnosed through polysomnography (PSG). Moderate to severe OSA can significantly increase morbidity and mortality. Existing screening tools have limited accuracy. This study aimed to evaluate the Wellue O2 ring, a commercial pulse oximeter ring, for screening moderate to severe OSA.
Methods: A cross-sectional study included adults aged 18 and older suspected of having OSA who underwent PSG while wearing the Wellue O2 ring on their thumb. The oxygen desaturation index (ODI) from both the O2 ring and PSG was recorded. Sensitivity, specificity, and receiver operating characteristic (ROC) curves were calculated to determine the optimal ODI cutoff value for predicting moderate to severe OSA.
Results: The study included 190 participants (53.2% male) with an average age of 43 years and an average apnea-hypopnea index (AHI) of 50.4 events per hour. Among the participants, 84.7% had moderate to severe OSA. The optimal cutoff value for 11% ODI was 1.25 events per hour lasting 20 s, with a sensitivity of 87.30% and a specificity of 78.70%. The area under the ROC curve for identifying moderate to severe OSA was 0.91.
Conclusions: The Wellue O2 ring demonstrated high accuracy in detecting moderate to severe OSA and could be a viable alternative for screening in clinical settings due to its accessibility and ease of use. However, larger studies are required to validate its clinical utility for diagnosing and managing moderate to severe OSA.
期刊介绍:
The journal Sleep and Breathing aims to reflect the state of the art in the international science and practice of sleep medicine. The journal is based on the recognition that management of sleep disorders requires a multi-disciplinary approach and diverse perspectives. The initial focus of Sleep and Breathing is on timely and original studies that collect, intervene, or otherwise inform all clinicians and scientists in medicine, dentistry and oral surgery, otolaryngology, and epidemiology on the management of the upper airway during sleep.
Furthermore, Sleep and Breathing endeavors to bring readers cutting edge information about all evolving aspects of common sleep disorders or disruptions, such as insomnia and shift work. The journal includes not only patient studies, but also studies that emphasize the principles of physiology and pathophysiology or illustrate potentially novel approaches to diagnosis and treatment. In addition, the journal features articles that describe patient-oriented and cost-benefit health outcomes research. Thus, with peer review by an international Editorial Board and prompt English-language publication, Sleep and Breathing provides rapid dissemination of clinical and clinically related scientific information. But it also does more: it is dedicated to making the most important developments in sleep disordered breathing easily accessible to clinicians who are treating sleep apnea by presenting well-chosen, well-written, and highly organized information that is useful for patient care.