{"title":"扭转超声乳化手术后的金属眼内异物。","authors":"Prabhjot Singh, Vikas Ambiya, Gaurav Kapoor, Vijay Kumar Sharma, Rahul, Jyothi Nandanan, Ashok Kumar","doi":"10.1080/08820538.2024.2443841","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to determine the rate of retained metallic intraocular foreign bodies (IOFBs) following torsional phacoemulsification cataract surgery by an experienced surgeon and elucidate related surgical factors, particle origin theories from existing literature, and postoperative visual impact.</p><p><strong>Methods: </strong>An observational study was conducted on 300 consecutive cases of cataract who underwent torsional phacoemulsification by a single surgeon using two-handed stop-and-chop technique. The incidence of retained IOFBs was observed and correlated with the surgical parameters and the density of cataract.</p><p><strong>Results: </strong>Retained IOFBs were observed in 6 of 300 (2%) cases operated. These were significantly associated with higher cumulative dissipated energy and the density of cataract, but without impacting final vision.</p><p><strong>Conclusion: </strong>Phacoemulsification retains inherent risks of metallic particle liberation from ultrasonically stressed instrumentation interacting within confined spaces. However, small retained IOFBs appear visually inconsequential over limited follow-up. Advances in technique, engineering design, and surgical quality control hold promise for further enhancing safety of the procedure.</p>","PeriodicalId":21702,"journal":{"name":"Seminars in Ophthalmology","volume":" ","pages":"1-5"},"PeriodicalIF":1.9000,"publicationDate":"2024-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Metallic Intraocular Foreign Bodies Following Torsional Phacoemulsification Surgery.\",\"authors\":\"Prabhjot Singh, Vikas Ambiya, Gaurav Kapoor, Vijay Kumar Sharma, Rahul, Jyothi Nandanan, Ashok Kumar\",\"doi\":\"10.1080/08820538.2024.2443841\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to determine the rate of retained metallic intraocular foreign bodies (IOFBs) following torsional phacoemulsification cataract surgery by an experienced surgeon and elucidate related surgical factors, particle origin theories from existing literature, and postoperative visual impact.</p><p><strong>Methods: </strong>An observational study was conducted on 300 consecutive cases of cataract who underwent torsional phacoemulsification by a single surgeon using two-handed stop-and-chop technique. The incidence of retained IOFBs was observed and correlated with the surgical parameters and the density of cataract.</p><p><strong>Results: </strong>Retained IOFBs were observed in 6 of 300 (2%) cases operated. These were significantly associated with higher cumulative dissipated energy and the density of cataract, but without impacting final vision.</p><p><strong>Conclusion: </strong>Phacoemulsification retains inherent risks of metallic particle liberation from ultrasonically stressed instrumentation interacting within confined spaces. However, small retained IOFBs appear visually inconsequential over limited follow-up. Advances in technique, engineering design, and surgical quality control hold promise for further enhancing safety of the procedure.</p>\",\"PeriodicalId\":21702,\"journal\":{\"name\":\"Seminars in Ophthalmology\",\"volume\":\" \",\"pages\":\"1-5\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-12-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Seminars in Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/08820538.2024.2443841\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/08820538.2024.2443841","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在确定由经验丰富的外科医生进行扭转性白内障超声乳化手术后金属眼内异物(IOFBs)的残留率,并阐明相关的手术因素、现有文献中的颗粒起源理论和术后视觉影响。方法:对连续300例白内障患者进行观察性研究,均为单刀行扭转型超声乳化术。观察保留IOFBs的发生率,并将其与手术参数和白内障密度相关。结果:300例手术中有6例(2%)观察到IOFBs残留。这些与较高的累积耗散能量和白内障密度显著相关,但不影响最终视力。结论:超声乳化术保留了固有的风险,即金属颗粒从超声应力仪器在密闭空间内相互作用中释放出来。然而,在有限的随访中,小的保留iofb在视觉上显得无关紧要。技术、工程设计和手术质量控制的进步有望进一步提高手术的安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Metallic Intraocular Foreign Bodies Following Torsional Phacoemulsification Surgery.

Purpose: This study aimed to determine the rate of retained metallic intraocular foreign bodies (IOFBs) following torsional phacoemulsification cataract surgery by an experienced surgeon and elucidate related surgical factors, particle origin theories from existing literature, and postoperative visual impact.

Methods: An observational study was conducted on 300 consecutive cases of cataract who underwent torsional phacoemulsification by a single surgeon using two-handed stop-and-chop technique. The incidence of retained IOFBs was observed and correlated with the surgical parameters and the density of cataract.

Results: Retained IOFBs were observed in 6 of 300 (2%) cases operated. These were significantly associated with higher cumulative dissipated energy and the density of cataract, but without impacting final vision.

Conclusion: Phacoemulsification retains inherent risks of metallic particle liberation from ultrasonically stressed instrumentation interacting within confined spaces. However, small retained IOFBs appear visually inconsequential over limited follow-up. Advances in technique, engineering design, and surgical quality control hold promise for further enhancing safety of the procedure.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Seminars in Ophthalmology
Seminars in Ophthalmology OPHTHALMOLOGY-
CiteScore
3.20
自引率
0.00%
发文量
80
审稿时长
>12 weeks
期刊介绍: Seminars in Ophthalmology offers current, clinically oriented reviews on the diagnosis and treatment of ophthalmic disorders. Each issue focuses on a single topic, with a primary emphasis on appropriate surgical techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信