新型管壳式热交换器设计,采用可供选择的倾斜挡板

IF 6.4 2区 工程技术 Q1 THERMODYNAMICS
Huy Minh Khoi Hoang, Hai-Lam Cao, Phuoc Minh Quang Pham, Ahmad Hajjar, Vu Linh Nguyen
{"title":"新型管壳式热交换器设计,采用可供选择的倾斜挡板","authors":"Huy Minh Khoi Hoang, Hai-Lam Cao, Phuoc Minh Quang Pham, Ahmad Hajjar, Vu Linh Nguyen","doi":"10.1016/j.csite.2024.105542","DOIUrl":null,"url":null,"abstract":"This paper proposes a novel single-shell-pass shell-and-tube heat exchanger design with alternative inclined baffles. The design includes paired semi-ellipse shapes with baffle cut along the vertical axis such that the segments are interlocked in a crossed pattern. The new exchanger is structured to overcome the weakness of single segmental baffles (SG-STHX) by achieving lower pressure drop and higher thermal efficiency. This advantage is achieved using spiral flow to reduce dead zones and make the flow distribution within the heat exchanger's shell more uniform. The relatively simple arrangement and design of baffles in the proposed exchanger offer a significant advantage compared to continuous helical baffles (CH-STHX) in terms of the complexity of manufacturing and consequent high cost. In this paper, the equations governing the flow and thermal transfer in the exchanger are presented, and the parameters used to evaluate the exchanger's performance are also developed. The finite-volume method is used in numerical simulations to verify the equations and compare the performance of the novel design to SG-STHX and CH-STHX under similar geometrical and thermo-hydraulic conditions. Different mass flow rates are considered to cover a wide range of Reynolds numbers and ensure the accuracy of the comparison. Flow velocity and temperature distributions across the shell side are plotted to address the impact of geometry on the fluid behavior during the flow. The results show that the proposed heat exchanger significantly improves comprehensive performance, especially energy efficiency, compared to conventional SG-STHX or CH-STHX. The proposed heat exchanger also has a lower pressure drop than traditional ones. With the same mass flow rate, the XX-STHX demonstrates an average pressure drop approximately 44 % lower than the CH-STHX and 49 % lower than the SG-STHX. Moreover, with the same pump power, the performance evaluation factor of the XX-STHX, on average, surpasses that of the CH-STHX by roughly 1.48 times and the SG-STHX by about 1.70 times.","PeriodicalId":9658,"journal":{"name":"Case Studies in Thermal Engineering","volume":"21 1","pages":""},"PeriodicalIF":6.4000,"publicationDate":"2024-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A novel shell-and-tube heat exchanger design with alternative inclined baffles\",\"authors\":\"Huy Minh Khoi Hoang, Hai-Lam Cao, Phuoc Minh Quang Pham, Ahmad Hajjar, Vu Linh Nguyen\",\"doi\":\"10.1016/j.csite.2024.105542\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a novel single-shell-pass shell-and-tube heat exchanger design with alternative inclined baffles. The design includes paired semi-ellipse shapes with baffle cut along the vertical axis such that the segments are interlocked in a crossed pattern. The new exchanger is structured to overcome the weakness of single segmental baffles (SG-STHX) by achieving lower pressure drop and higher thermal efficiency. This advantage is achieved using spiral flow to reduce dead zones and make the flow distribution within the heat exchanger's shell more uniform. The relatively simple arrangement and design of baffles in the proposed exchanger offer a significant advantage compared to continuous helical baffles (CH-STHX) in terms of the complexity of manufacturing and consequent high cost. In this paper, the equations governing the flow and thermal transfer in the exchanger are presented, and the parameters used to evaluate the exchanger's performance are also developed. The finite-volume method is used in numerical simulations to verify the equations and compare the performance of the novel design to SG-STHX and CH-STHX under similar geometrical and thermo-hydraulic conditions. Different mass flow rates are considered to cover a wide range of Reynolds numbers and ensure the accuracy of the comparison. Flow velocity and temperature distributions across the shell side are plotted to address the impact of geometry on the fluid behavior during the flow. The results show that the proposed heat exchanger significantly improves comprehensive performance, especially energy efficiency, compared to conventional SG-STHX or CH-STHX. The proposed heat exchanger also has a lower pressure drop than traditional ones. With the same mass flow rate, the XX-STHX demonstrates an average pressure drop approximately 44 % lower than the CH-STHX and 49 % lower than the SG-STHX. Moreover, with the same pump power, the performance evaluation factor of the XX-STHX, on average, surpasses that of the CH-STHX by roughly 1.48 times and the SG-STHX by about 1.70 times.\",\"PeriodicalId\":9658,\"journal\":{\"name\":\"Case Studies in Thermal Engineering\",\"volume\":\"21 1\",\"pages\":\"\"},\"PeriodicalIF\":6.4000,\"publicationDate\":\"2024-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Case Studies in Thermal Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1016/j.csite.2024.105542\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"THERMODYNAMICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Studies in Thermal Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1016/j.csite.2024.105542","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"THERMODYNAMICS","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel shell-and-tube heat exchanger design with alternative inclined baffles
This paper proposes a novel single-shell-pass shell-and-tube heat exchanger design with alternative inclined baffles. The design includes paired semi-ellipse shapes with baffle cut along the vertical axis such that the segments are interlocked in a crossed pattern. The new exchanger is structured to overcome the weakness of single segmental baffles (SG-STHX) by achieving lower pressure drop and higher thermal efficiency. This advantage is achieved using spiral flow to reduce dead zones and make the flow distribution within the heat exchanger's shell more uniform. The relatively simple arrangement and design of baffles in the proposed exchanger offer a significant advantage compared to continuous helical baffles (CH-STHX) in terms of the complexity of manufacturing and consequent high cost. In this paper, the equations governing the flow and thermal transfer in the exchanger are presented, and the parameters used to evaluate the exchanger's performance are also developed. The finite-volume method is used in numerical simulations to verify the equations and compare the performance of the novel design to SG-STHX and CH-STHX under similar geometrical and thermo-hydraulic conditions. Different mass flow rates are considered to cover a wide range of Reynolds numbers and ensure the accuracy of the comparison. Flow velocity and temperature distributions across the shell side are plotted to address the impact of geometry on the fluid behavior during the flow. The results show that the proposed heat exchanger significantly improves comprehensive performance, especially energy efficiency, compared to conventional SG-STHX or CH-STHX. The proposed heat exchanger also has a lower pressure drop than traditional ones. With the same mass flow rate, the XX-STHX demonstrates an average pressure drop approximately 44 % lower than the CH-STHX and 49 % lower than the SG-STHX. Moreover, with the same pump power, the performance evaluation factor of the XX-STHX, on average, surpasses that of the CH-STHX by roughly 1.48 times and the SG-STHX by about 1.70 times.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Case Studies in Thermal Engineering
Case Studies in Thermal Engineering Chemical Engineering-Fluid Flow and Transfer Processes
CiteScore
8.60
自引率
11.80%
发文量
812
审稿时长
76 days
期刊介绍: Case Studies in Thermal Engineering provides a forum for the rapid publication of short, structured Case Studies in Thermal Engineering and related Short Communications. It provides an essential compendium of case studies for researchers and practitioners in the field of thermal engineering and others who are interested in aspects of thermal engineering cases that could affect other engineering processes. The journal not only publishes new and novel case studies, but also provides a forum for the publication of high quality descriptions of classic thermal engineering problems. The scope of the journal includes case studies of thermal engineering problems in components, devices and systems using existing experimental and numerical techniques in the areas of mechanical, aerospace, chemical, medical, thermal management for electronics, heat exchangers, regeneration, solar thermal energy, thermal storage, building energy conservation, and power generation. Case studies of thermal problems in other areas will also be considered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信