Matthew S Russell, Sam S Vasilounis, Daniel Desroches, Talia Alenabi, Janessa D M Drake, Jaclyn N Chopp-Hurley
{"title":"评估体表和肌内肌电信号之间的关系:对皮下脂肪厚度的影响。","authors":"Matthew S Russell, Sam S Vasilounis, Daniel Desroches, Talia Alenabi, Janessa D M Drake, Jaclyn N Chopp-Hurley","doi":"10.1123/jab.2024-0101","DOIUrl":null,"url":null,"abstract":"<p><p>Intramuscular (iEMG) and surface electromyographic (sEMG) signals have been compared previously using predictive regression equations, finite element modeling, and correlation and cross-correlation analyses. Although subcutaneous fat thickness (SCFT) has been identified as a primary source of sEMG signal amplitude attenuation and low-pass filter equivalence, few studies have explored the potential effect of SCFT on sEMG and iEMG signal characteristics. The purpose of this study was to investigate the relationship between normalized submaximal iEMG and sEMG signal amplitudes collected from 4 muscles (rectus femoris, vastus lateralis, infraspinatus, and erector spinae) and determine whether SCFT explains more variance in this relationship. The effect of sex was also explored. Linear regression models demonstrated that the relationship between sEMG and iEMG was highly variable across the muscles examined (adjusted coefficient of determination [Adj R2] = .02-.74). SCFT improved the model fit for vastus lateralis, although this relationship only emerged with the inclusion of sex as a covariate. Thus, this research suggests that SCFT is not a prominent factor affecting the linearity between sEMG and iEMG. Researchers should investigate other parameters that may affect the linearity between sEMG and iEMG signals.</p>","PeriodicalId":54883,"journal":{"name":"Journal of Applied Biomechanics","volume":" ","pages":"47-55"},"PeriodicalIF":1.3000,"publicationDate":"2024-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluating the Relationship Between Surface and Intramuscular-Based Electromyography Signals: Implications of Subcutaneous Fat Thickness.\",\"authors\":\"Matthew S Russell, Sam S Vasilounis, Daniel Desroches, Talia Alenabi, Janessa D M Drake, Jaclyn N Chopp-Hurley\",\"doi\":\"10.1123/jab.2024-0101\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Intramuscular (iEMG) and surface electromyographic (sEMG) signals have been compared previously using predictive regression equations, finite element modeling, and correlation and cross-correlation analyses. Although subcutaneous fat thickness (SCFT) has been identified as a primary source of sEMG signal amplitude attenuation and low-pass filter equivalence, few studies have explored the potential effect of SCFT on sEMG and iEMG signal characteristics. The purpose of this study was to investigate the relationship between normalized submaximal iEMG and sEMG signal amplitudes collected from 4 muscles (rectus femoris, vastus lateralis, infraspinatus, and erector spinae) and determine whether SCFT explains more variance in this relationship. The effect of sex was also explored. Linear regression models demonstrated that the relationship between sEMG and iEMG was highly variable across the muscles examined (adjusted coefficient of determination [Adj R2] = .02-.74). SCFT improved the model fit for vastus lateralis, although this relationship only emerged with the inclusion of sex as a covariate. Thus, this research suggests that SCFT is not a prominent factor affecting the linearity between sEMG and iEMG. Researchers should investigate other parameters that may affect the linearity between sEMG and iEMG signals.</p>\",\"PeriodicalId\":54883,\"journal\":{\"name\":\"Journal of Applied Biomechanics\",\"volume\":\" \",\"pages\":\"47-55\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Biomechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1123/jab.2024-0101\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/2/1 0:00:00\",\"PubModel\":\"Print\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1123/jab.2024-0101","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/1 0:00:00","PubModel":"Print","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Evaluating the Relationship Between Surface and Intramuscular-Based Electromyography Signals: Implications of Subcutaneous Fat Thickness.
Intramuscular (iEMG) and surface electromyographic (sEMG) signals have been compared previously using predictive regression equations, finite element modeling, and correlation and cross-correlation analyses. Although subcutaneous fat thickness (SCFT) has been identified as a primary source of sEMG signal amplitude attenuation and low-pass filter equivalence, few studies have explored the potential effect of SCFT on sEMG and iEMG signal characteristics. The purpose of this study was to investigate the relationship between normalized submaximal iEMG and sEMG signal amplitudes collected from 4 muscles (rectus femoris, vastus lateralis, infraspinatus, and erector spinae) and determine whether SCFT explains more variance in this relationship. The effect of sex was also explored. Linear regression models demonstrated that the relationship between sEMG and iEMG was highly variable across the muscles examined (adjusted coefficient of determination [Adj R2] = .02-.74). SCFT improved the model fit for vastus lateralis, although this relationship only emerged with the inclusion of sex as a covariate. Thus, this research suggests that SCFT is not a prominent factor affecting the linearity between sEMG and iEMG. Researchers should investigate other parameters that may affect the linearity between sEMG and iEMG signals.
期刊介绍:
The mission of the Journal of Applied Biomechanics (JAB) is to disseminate the highest quality peer-reviewed studies that utilize biomechanical strategies to advance the study of human movement. Areas of interest include clinical biomechanics, gait and posture mechanics, musculoskeletal and neuromuscular biomechanics, sport mechanics, and biomechanical modeling. Studies of sport performance that explicitly generalize to broader activities, contribute substantially to fundamental understanding of human motion, or are in a sport that enjoys wide participation, are welcome. Also within the scope of JAB are studies using biomechanical strategies to investigate the structure, control, function, and state (health and disease) of animals.