Anita Howell, Angela Hill, Wanda Lefresne, Brandie Dennis, Tracey R Turner, Qi-Long Yi, Carly Olafson, Nishaka William, Jason P Acker
{"title":"使用改进的ACP-215协议输入体积对脱甘油红细胞质量的影响。","authors":"Anita Howell, Angela Hill, Wanda Lefresne, Brandie Dennis, Tracey R Turner, Qi-Long Yi, Carly Olafson, Nishaka William, Jason P Acker","doi":"10.1111/trf.18088","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The ACP 215 automated cell processor is used to glycerolize and deglycerolize red cell concentrates (RCCs). Its primary advantage over the COBE 2991, previously used to cryopreserve RCCs, is that it maintains a closed system enabling extended post-thaw expiry. However, it was observed that post-deglycerolization hematocrits (Hct) of units processed with the LN236 kit are markedly lower than those processed using the COBE 2991. Therefore, we intended to determine whether a modified process using a smaller volume deglycerolization kit (LN235) could increase the final Hct with limited deleterious effects on product characteristics.</p><p><strong>Study design and methods: </strong>Two proof-of-concept (POC) studies, conducted to determine the feasibility of using the LN235 processing kit for deglycerolization, identified the necessary modifications to the pre- and post-deglycerolization process, after which a two-part study characterized the modified protocol. The impact of pre-cryopreservation storage duration (7-21 days), input red cell mass, and the type of CPD/SAGM RCC production method (red cell filtration and whole blood filtration) were investigated.</p><p><strong>Results: </strong>Using the LN235 kit in conjunction with a volume reduction step for RCCs with a red cell mass exceeding 180 mL allowed for an ~8% increase in Hct. As expected, slightly lower recoveries were seen for large RCCs due to volume reduction; however, there were no other detrimental outcomes on product quality.</p><p><strong>Conclusions: </strong>Leveraging the LN235 kit, recommended by Haemonetics for units with a red cell mass of ≤180 mL, can be used to increase the post-deglycerolization Hct of RCCs that exceed this volume.</p>","PeriodicalId":23266,"journal":{"name":"Transfusion","volume":" ","pages":"194-201"},"PeriodicalIF":2.5000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11747085/pdf/","citationCount":"0","resultStr":"{\"title\":\"Impact of input volume on red cell quality in deglycerolized RBCs using a modified ACP-215 protocol.\",\"authors\":\"Anita Howell, Angela Hill, Wanda Lefresne, Brandie Dennis, Tracey R Turner, Qi-Long Yi, Carly Olafson, Nishaka William, Jason P Acker\",\"doi\":\"10.1111/trf.18088\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The ACP 215 automated cell processor is used to glycerolize and deglycerolize red cell concentrates (RCCs). Its primary advantage over the COBE 2991, previously used to cryopreserve RCCs, is that it maintains a closed system enabling extended post-thaw expiry. However, it was observed that post-deglycerolization hematocrits (Hct) of units processed with the LN236 kit are markedly lower than those processed using the COBE 2991. Therefore, we intended to determine whether a modified process using a smaller volume deglycerolization kit (LN235) could increase the final Hct with limited deleterious effects on product characteristics.</p><p><strong>Study design and methods: </strong>Two proof-of-concept (POC) studies, conducted to determine the feasibility of using the LN235 processing kit for deglycerolization, identified the necessary modifications to the pre- and post-deglycerolization process, after which a two-part study characterized the modified protocol. The impact of pre-cryopreservation storage duration (7-21 days), input red cell mass, and the type of CPD/SAGM RCC production method (red cell filtration and whole blood filtration) were investigated.</p><p><strong>Results: </strong>Using the LN235 kit in conjunction with a volume reduction step for RCCs with a red cell mass exceeding 180 mL allowed for an ~8% increase in Hct. As expected, slightly lower recoveries were seen for large RCCs due to volume reduction; however, there were no other detrimental outcomes on product quality.</p><p><strong>Conclusions: </strong>Leveraging the LN235 kit, recommended by Haemonetics for units with a red cell mass of ≤180 mL, can be used to increase the post-deglycerolization Hct of RCCs that exceed this volume.</p>\",\"PeriodicalId\":23266,\"journal\":{\"name\":\"Transfusion\",\"volume\":\" \",\"pages\":\"194-201\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11747085/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transfusion\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/trf.18088\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transfusion","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/trf.18088","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:acp215全自动细胞处理机用于红细胞浓缩物(RCCs)的甘油化和脱甘油化。与COBE 2991相比,它的主要优势在于它保持了一个封闭的系统,可以延长解冻后的有效期。COBE 2991以前用于冷冻保存rcc。然而,观察到使用LN236试剂盒处理的单位的脱甘油后血细胞比容(Hct)明显低于使用COBE 2991处理的单位。因此,我们打算确定使用更小体积脱甘油试剂盒(LN235)的改进工艺是否可以在对产品特性有害影响有限的情况下增加最终Hct。研究设计和方法:进行了两项概念验证(POC)研究,以确定使用LN235处理试剂盒进行脱甘油的可行性,确定了对脱甘油前和脱甘油后过程的必要修改,之后进行了两部分研究,对修改后的方案进行了表征。研究了冷冻前保存时间(7-21天)、输入红细胞质量和CPD/SAGM RCC生产方法(红细胞过滤和全血过滤)的影响。结果:使用LN235试剂盒结合体积缩小步骤,对于红细胞质量超过180 mL的rcc,可使Hct增加约8%。正如预期的那样,由于体积减小,大型rcc的采收率略低;然而,对产品质量没有其他不利影响。结论:利用Haemonetics推荐的用于红细胞体积≤180ml单位的LN235试剂盒,可用于增加超过此体积的rcc的脱甘油后Hct。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of input volume on red cell quality in deglycerolized RBCs using a modified ACP-215 protocol.

Background: The ACP 215 automated cell processor is used to glycerolize and deglycerolize red cell concentrates (RCCs). Its primary advantage over the COBE 2991, previously used to cryopreserve RCCs, is that it maintains a closed system enabling extended post-thaw expiry. However, it was observed that post-deglycerolization hematocrits (Hct) of units processed with the LN236 kit are markedly lower than those processed using the COBE 2991. Therefore, we intended to determine whether a modified process using a smaller volume deglycerolization kit (LN235) could increase the final Hct with limited deleterious effects on product characteristics.

Study design and methods: Two proof-of-concept (POC) studies, conducted to determine the feasibility of using the LN235 processing kit for deglycerolization, identified the necessary modifications to the pre- and post-deglycerolization process, after which a two-part study characterized the modified protocol. The impact of pre-cryopreservation storage duration (7-21 days), input red cell mass, and the type of CPD/SAGM RCC production method (red cell filtration and whole blood filtration) were investigated.

Results: Using the LN235 kit in conjunction with a volume reduction step for RCCs with a red cell mass exceeding 180 mL allowed for an ~8% increase in Hct. As expected, slightly lower recoveries were seen for large RCCs due to volume reduction; however, there were no other detrimental outcomes on product quality.

Conclusions: Leveraging the LN235 kit, recommended by Haemonetics for units with a red cell mass of ≤180 mL, can be used to increase the post-deglycerolization Hct of RCCs that exceed this volume.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Transfusion
Transfusion 医学-血液学
CiteScore
4.70
自引率
20.70%
发文量
426
审稿时长
1 months
期刊介绍: TRANSFUSION is the foremost publication in the world for new information regarding transfusion medicine. Written by and for members of AABB and other health-care workers, TRANSFUSION reports on the latest technical advances, discusses opposing viewpoints regarding controversial issues, and presents key conference proceedings. In addition to blood banking and transfusion medicine topics, TRANSFUSION presents submissions concerning patient blood management, tissue transplantation and hematopoietic, cellular, and gene therapies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信