{"title":"基于免疫分析法的高特异性单克隆抗体检测SARS-CoV-2生物传感器平台设计","authors":"Göknur Gizem Dinç , Ebru Saatçi , İlkay Göksu Polat , Fatıma Yücel , Uygar Halis Tazebay , Esin Akçael","doi":"10.1016/j.diagmicrobio.2024.116644","DOIUrl":null,"url":null,"abstract":"<div><div>The global expand of SARS-CoV-2 has highlighted the importance of early and rapid detection to control the spread of a pandemic. In this study, specific and high-affinity monoclonal antibodies (mAbs) were developed against the conserved nucleocapsid protein of the virus among variants. Appropriate antibody pairs were selected to develop a lateral flow immunoassay (LFIA) and an unconventional application of an amperometric biosensor using unmodified screen-printed electrodes and external magnetic bead preparation. In the study, the LFIA we developed detected the SARS-CoV-2 virus at 10<sup>4</sup> PFU/mL, while the amperometric biosensor enabled sensitive detection of inactivated SARS-CoV-2 with an LOD of 5.5 PFU/mL. After validating the developed systems, it is considered that the mAbs we have obtained will enable the sensitive and selective detection of SARS-CoV-2 in LFIA and amperometric immunosensor platforms for clinical diagnosis.</div></div>","PeriodicalId":11329,"journal":{"name":"Diagnostic microbiology and infectious disease","volume":"111 3","pages":"Article 116644"},"PeriodicalIF":2.1000,"publicationDate":"2024-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of immunoassay based biosensor platforms for SARS-CoV-2 detection using highly specific monoclonal antibodies\",\"authors\":\"Göknur Gizem Dinç , Ebru Saatçi , İlkay Göksu Polat , Fatıma Yücel , Uygar Halis Tazebay , Esin Akçael\",\"doi\":\"10.1016/j.diagmicrobio.2024.116644\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The global expand of SARS-CoV-2 has highlighted the importance of early and rapid detection to control the spread of a pandemic. In this study, specific and high-affinity monoclonal antibodies (mAbs) were developed against the conserved nucleocapsid protein of the virus among variants. Appropriate antibody pairs were selected to develop a lateral flow immunoassay (LFIA) and an unconventional application of an amperometric biosensor using unmodified screen-printed electrodes and external magnetic bead preparation. In the study, the LFIA we developed detected the SARS-CoV-2 virus at 10<sup>4</sup> PFU/mL, while the amperometric biosensor enabled sensitive detection of inactivated SARS-CoV-2 with an LOD of 5.5 PFU/mL. After validating the developed systems, it is considered that the mAbs we have obtained will enable the sensitive and selective detection of SARS-CoV-2 in LFIA and amperometric immunosensor platforms for clinical diagnosis.</div></div>\",\"PeriodicalId\":11329,\"journal\":{\"name\":\"Diagnostic microbiology and infectious disease\",\"volume\":\"111 3\",\"pages\":\"Article 116644\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostic microbiology and infectious disease\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0732889324004681\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INFECTIOUS DISEASES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic microbiology and infectious disease","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0732889324004681","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
Design of immunoassay based biosensor platforms for SARS-CoV-2 detection using highly specific monoclonal antibodies
The global expand of SARS-CoV-2 has highlighted the importance of early and rapid detection to control the spread of a pandemic. In this study, specific and high-affinity monoclonal antibodies (mAbs) were developed against the conserved nucleocapsid protein of the virus among variants. Appropriate antibody pairs were selected to develop a lateral flow immunoassay (LFIA) and an unconventional application of an amperometric biosensor using unmodified screen-printed electrodes and external magnetic bead preparation. In the study, the LFIA we developed detected the SARS-CoV-2 virus at 104 PFU/mL, while the amperometric biosensor enabled sensitive detection of inactivated SARS-CoV-2 with an LOD of 5.5 PFU/mL. After validating the developed systems, it is considered that the mAbs we have obtained will enable the sensitive and selective detection of SARS-CoV-2 in LFIA and amperometric immunosensor platforms for clinical diagnosis.
期刊介绍:
Diagnostic Microbiology and Infectious Disease keeps you informed of the latest developments in clinical microbiology and the diagnosis and treatment of infectious diseases. Packed with rigorously peer-reviewed articles and studies in bacteriology, immunology, immunoserology, infectious diseases, mycology, parasitology, and virology, the journal examines new procedures, unusual cases, controversial issues, and important new literature. Diagnostic Microbiology and Infectious Disease distinguished independent editorial board, consisting of experts from many medical specialties, ensures you extensive and authoritative coverage.