{"title":"肝/脾磁共振弹性成像和T1/T2定位在慢性肝病中的前瞻性研究","authors":"Gökhan Mert Özyurt, Kaan Esen, Enver Üçbilek, Feramuz Demir Apaydın","doi":"10.1590/1806-9282.20241008","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aims to compare liver and spleen stiffness measurements using magnetic resonance elastography with T1 and T2 relaxation times in patients with chronic liver disease.</p><p><strong>Methods: </strong>A total of 75 chronic liver disease patients and 25 healthy volunteers underwent MR. Patients with significant liver fat and iron accumulation were excluded. Student's t-test was employed to compare magnetic resonance elastography and T1/T2 values. Pearson's correlation test was used to assess the relationship between magnetic resonance elastography and T1/T2 values.</p><p><strong>Results: </strong>Liver magnetic resonance elastography showed a significant moderate positive correlation with liver T1 mapping (r=0.51, p<0.001) and liver T2 mapping (r=0.30, p=0.009) in patients. Spleen magnetic resonance elastography exhibited a significant moderate positive correlation with spleen T2 mapping (r=0.37, p=0.001). However, there was no significant correlation between spleen magnetic resonance elastography and spleen T1 mapping in patients. Spleen magnetic resonance elastography was moderately positively correlated with liver magnetic resonance elastography (r=0.30, p=0.01), and spleen volume showed positive correlations with spleen magnetic resonance elastography, spleen T1 mapping, and spleen T2 mapping. Cut-off values for liver magnetic resonance elastography, liver T1 mapping, and liver T2 mapping in patient and control groups were 2.6 kPa (AUC=0.97), 619 ms (AUC=0.90), and 52.5 ms (AUC=0.62), respectively.</p><p><strong>Conclusion: </strong>Relaxation methods offer noninvasive imaging without additional equipment. Liver T1 mapping may serve as an alternative to magnetic resonance elastography for chronic liver patient follow-up, while spleen T1 mapping is not reliable.</p>","PeriodicalId":94194,"journal":{"name":"Revista da Associacao Medica Brasileira (1992)","volume":"70 12","pages":"e20241008"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11639558/pdf/","citationCount":"0","resultStr":"{\"title\":\"Liver/spleen magnetic resonance elastography and T1/T2 mapping in chronic liver disease: a prospective study.\",\"authors\":\"Gökhan Mert Özyurt, Kaan Esen, Enver Üçbilek, Feramuz Demir Apaydın\",\"doi\":\"10.1590/1806-9282.20241008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This study aims to compare liver and spleen stiffness measurements using magnetic resonance elastography with T1 and T2 relaxation times in patients with chronic liver disease.</p><p><strong>Methods: </strong>A total of 75 chronic liver disease patients and 25 healthy volunteers underwent MR. Patients with significant liver fat and iron accumulation were excluded. Student's t-test was employed to compare magnetic resonance elastography and T1/T2 values. Pearson's correlation test was used to assess the relationship between magnetic resonance elastography and T1/T2 values.</p><p><strong>Results: </strong>Liver magnetic resonance elastography showed a significant moderate positive correlation with liver T1 mapping (r=0.51, p<0.001) and liver T2 mapping (r=0.30, p=0.009) in patients. Spleen magnetic resonance elastography exhibited a significant moderate positive correlation with spleen T2 mapping (r=0.37, p=0.001). However, there was no significant correlation between spleen magnetic resonance elastography and spleen T1 mapping in patients. Spleen magnetic resonance elastography was moderately positively correlated with liver magnetic resonance elastography (r=0.30, p=0.01), and spleen volume showed positive correlations with spleen magnetic resonance elastography, spleen T1 mapping, and spleen T2 mapping. Cut-off values for liver magnetic resonance elastography, liver T1 mapping, and liver T2 mapping in patient and control groups were 2.6 kPa (AUC=0.97), 619 ms (AUC=0.90), and 52.5 ms (AUC=0.62), respectively.</p><p><strong>Conclusion: </strong>Relaxation methods offer noninvasive imaging without additional equipment. Liver T1 mapping may serve as an alternative to magnetic resonance elastography for chronic liver patient follow-up, while spleen T1 mapping is not reliable.</p>\",\"PeriodicalId\":94194,\"journal\":{\"name\":\"Revista da Associacao Medica Brasileira (1992)\",\"volume\":\"70 12\",\"pages\":\"e20241008\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-12-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11639558/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista da Associacao Medica Brasileira (1992)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/1806-9282.20241008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista da Associacao Medica Brasileira (1992)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/1806-9282.20241008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较磁共振弹性成像测量慢性肝病患者肝脏和脾脏的T1和T2松弛时间的刚度。方法:共75例慢性肝病患者和25例健康志愿者接受mr治疗,排除肝脏脂肪和铁积累明显的患者。采用学生t检验比较磁共振弹性图和T1/T2值。采用Pearson相关检验评估磁共振弹性成像与T1/T2值的关系。结果:肝脏磁共振弹性成像与肝脏T1显像呈正相关(r=0.51, p)。结论:松弛法无创成像,无需额外设备。肝脏T1作图可替代磁共振弹性成像用于慢性肝病患者随访,而脾脏T1作图不可靠。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Liver/spleen magnetic resonance elastography and T1/T2 mapping in chronic liver disease: a prospective study.

Objective: This study aims to compare liver and spleen stiffness measurements using magnetic resonance elastography with T1 and T2 relaxation times in patients with chronic liver disease.

Methods: A total of 75 chronic liver disease patients and 25 healthy volunteers underwent MR. Patients with significant liver fat and iron accumulation were excluded. Student's t-test was employed to compare magnetic resonance elastography and T1/T2 values. Pearson's correlation test was used to assess the relationship between magnetic resonance elastography and T1/T2 values.

Results: Liver magnetic resonance elastography showed a significant moderate positive correlation with liver T1 mapping (r=0.51, p<0.001) and liver T2 mapping (r=0.30, p=0.009) in patients. Spleen magnetic resonance elastography exhibited a significant moderate positive correlation with spleen T2 mapping (r=0.37, p=0.001). However, there was no significant correlation between spleen magnetic resonance elastography and spleen T1 mapping in patients. Spleen magnetic resonance elastography was moderately positively correlated with liver magnetic resonance elastography (r=0.30, p=0.01), and spleen volume showed positive correlations with spleen magnetic resonance elastography, spleen T1 mapping, and spleen T2 mapping. Cut-off values for liver magnetic resonance elastography, liver T1 mapping, and liver T2 mapping in patient and control groups were 2.6 kPa (AUC=0.97), 619 ms (AUC=0.90), and 52.5 ms (AUC=0.62), respectively.

Conclusion: Relaxation methods offer noninvasive imaging without additional equipment. Liver T1 mapping may serve as an alternative to magnetic resonance elastography for chronic liver patient follow-up, while spleen T1 mapping is not reliable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信