{"title":"脉冲场消融对冠状动脉的损伤。","authors":"Satoshi Higuchi, Edward P Gerstenfeld","doi":"10.1097/HCO.0000000000001181","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose of review: </strong>Although pulsed field ablation (PFA) has emerged as an innovative nonthermal catheter ablation modality, recent reports raise concerns about its potential impact on nearby coronary arteries. This review provides a comprehensive overview of the current understanding and future directions regarding the effects of PFA on or near coronary arteries.</p><p><strong>Recent findings: </strong>Clinical studies have demonstrated the risks of acute transient vasospasm after delivery of PFA, especially with ablation of structures in proximity to the coronary arteries, such as the cavotricuspid and mitral isthmuses. The clinical incidence has been reported to be approximately 0.14%, according to the largest multicenter registry. Nitroglycerin pretreatment has been demonstrated to mitigate vasospastic events. However, early preclinical models indicate that chronic neointimal hyperplasia, tunica media fibrosis and mild coronary artery narrowing may occur, suggesting long-term coronary injury after delivering PFA near coronary arteries.</p><p><strong>Summary: </strong>Despite reducing collateral tissue damage compared with thermal methods, PFA near coronary arteries may require careful procedural planning and proactive use of nitroglycerin to reduce coronary vasospasm. Further research is essential to elucidate the mechanisms underlying PFA-induced coronary spasm, optimize catheter design and placement, and assess the long-term coronary health implications.</p>","PeriodicalId":55197,"journal":{"name":"Current Opinion in Cardiology","volume":"40 1","pages":"22-30"},"PeriodicalIF":2.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Coronary artery injury in pulsed field ablation.\",\"authors\":\"Satoshi Higuchi, Edward P Gerstenfeld\",\"doi\":\"10.1097/HCO.0000000000001181\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose of review: </strong>Although pulsed field ablation (PFA) has emerged as an innovative nonthermal catheter ablation modality, recent reports raise concerns about its potential impact on nearby coronary arteries. This review provides a comprehensive overview of the current understanding and future directions regarding the effects of PFA on or near coronary arteries.</p><p><strong>Recent findings: </strong>Clinical studies have demonstrated the risks of acute transient vasospasm after delivery of PFA, especially with ablation of structures in proximity to the coronary arteries, such as the cavotricuspid and mitral isthmuses. The clinical incidence has been reported to be approximately 0.14%, according to the largest multicenter registry. Nitroglycerin pretreatment has been demonstrated to mitigate vasospastic events. However, early preclinical models indicate that chronic neointimal hyperplasia, tunica media fibrosis and mild coronary artery narrowing may occur, suggesting long-term coronary injury after delivering PFA near coronary arteries.</p><p><strong>Summary: </strong>Despite reducing collateral tissue damage compared with thermal methods, PFA near coronary arteries may require careful procedural planning and proactive use of nitroglycerin to reduce coronary vasospasm. Further research is essential to elucidate the mechanisms underlying PFA-induced coronary spasm, optimize catheter design and placement, and assess the long-term coronary health implications.</p>\",\"PeriodicalId\":55197,\"journal\":{\"name\":\"Current Opinion in Cardiology\",\"volume\":\"40 1\",\"pages\":\"22-30\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Opinion in Cardiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/HCO.0000000000001181\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/23 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Opinion in Cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/HCO.0000000000001181","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/23 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

回顾目的:虽然脉冲场消融(PFA)已成为一种创新的非热导管消融方式,但最近的报道引起了人们对其对附近冠状动脉的潜在影响的担忧。本文综述了目前对PFA对冠状动脉或冠状动脉附近的影响的理解和未来的发展方向。近期发现:临床研究表明,PFA分娩后存在急性短暂性血管痉挛的风险,特别是消融冠状动脉附近的结构,如颈三尖瓣和二尖瓣峡。根据最大的多中心登记,临床发病率约为0.14%。硝酸甘油预处理已被证明可以减轻血管痉挛事件。然而,早期临床前模型显示,可能发生慢性内膜增生、中膜纤维化和轻度冠状动脉狭窄,提示在冠状动脉附近输送PFA后,冠状动脉长期损伤。总结:尽管与热法相比可以减少侧支组织损伤,但冠状动脉附近的PFA可能需要仔细的手术计划和主动使用硝酸甘油来减少冠状动脉血管痉挛。进一步的研究需要阐明pfa诱导的冠状动脉痉挛的机制,优化导管的设计和放置,并评估长期的冠状动脉健康影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Coronary artery injury in pulsed field ablation.

Purpose of review: Although pulsed field ablation (PFA) has emerged as an innovative nonthermal catheter ablation modality, recent reports raise concerns about its potential impact on nearby coronary arteries. This review provides a comprehensive overview of the current understanding and future directions regarding the effects of PFA on or near coronary arteries.

Recent findings: Clinical studies have demonstrated the risks of acute transient vasospasm after delivery of PFA, especially with ablation of structures in proximity to the coronary arteries, such as the cavotricuspid and mitral isthmuses. The clinical incidence has been reported to be approximately 0.14%, according to the largest multicenter registry. Nitroglycerin pretreatment has been demonstrated to mitigate vasospastic events. However, early preclinical models indicate that chronic neointimal hyperplasia, tunica media fibrosis and mild coronary artery narrowing may occur, suggesting long-term coronary injury after delivering PFA near coronary arteries.

Summary: Despite reducing collateral tissue damage compared with thermal methods, PFA near coronary arteries may require careful procedural planning and proactive use of nitroglycerin to reduce coronary vasospasm. Further research is essential to elucidate the mechanisms underlying PFA-induced coronary spasm, optimize catheter design and placement, and assess the long-term coronary health implications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current Opinion in Cardiology
Current Opinion in Cardiology 医学-心血管系统
CiteScore
4.20
自引率
4.30%
发文量
78
审稿时长
6-12 weeks
期刊介绍: ​​​​​​Current Opinion in Cardiology is a bimonthly publication offering a unique and wide ranging perspective on the key developments in the field. Each issue features hand-picked review articles from our team of expert editors. With fourteen disciplines published across the year – including arrhythmias, molecular genetics, HDL cholesterol and clinical trials – every issue also contains annotated reference detailing the merits of the most important papers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信