去除房水和结膜压迫缝合线治疗过敏性滤过性水泡:一种外科技术和病例报告。

IF 1.4 4区 医学 Q3 OPHTHALMOLOGY
Elena Arias-García, Cristina Martinez-Gil, Marc Bautista-Cortiella, Gonzalo Roig-Ferreruela, Jose Vicente Piá-Ludeña, Aitor Lanzagorta-Aresti
{"title":"去除房水和结膜压迫缝合线治疗过敏性滤过性水泡:一种外科技术和病例报告。","authors":"Elena Arias-García, Cristina Martinez-Gil, Marc Bautista-Cortiella, Gonzalo Roig-Ferreruela, Jose Vicente Piá-Ludeña, Aitor Lanzagorta-Aresti","doi":"10.1177/11206721241304157","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>To present a novel surgical technique for the treatment of a steep-walled filtering bleb following an Ahmed glaucoma valve implant. The primary aim was to alleviate the patient's discomfort and address associated corneal thinning, complications that can arise from this condition.</p><p><strong>Methods: </strong>Case report and surgical technique. This case report describes a 29-year-old female who developed a dysesthesic filtering bleb following the implantation of a glaucoma drainage device. The employed surgical technique to address this complication involved the drainage of aqueous from the bleb using a 30-G needle, which effectively reduced its height. Subsequently, a compression suture was applied to maintain an appropriate bleb size.</p><p><strong>Results: </strong>With the presented surgical technique, the ultimate control of an overhigh filtering bleb associated to a glaucoma drainage device was possible. Following the procedure, the patient's symptoms and the corneal thinning linked to the bleb's excessive size were successfully managed. Furthermore, the anatomy of the filtering bleb was preserved, and an optimal intraocular pressure outcome was achieved.</p><p><strong>Conclusions: </strong>The removal of aqueous and the application of a compression suture are two surgical techniques traditionally used for managing the hypertensive phase of glaucoma drainage devices and for alleviating discomfort from blebs after classical filtering surgery, respectively. In the case presented, the combination of these two techniques effectively reduced the size of an excessively high filtering bleb associated with a glaucoma drainage device. This approach successfully resolved the patient's discomfort and corneal issues related to this complication.</p>","PeriodicalId":12000,"journal":{"name":"European Journal of Ophthalmology","volume":" ","pages":"11206721241304157"},"PeriodicalIF":1.4000,"publicationDate":"2024-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Removal of aqueous humor and conjunctival compression sutures for a dysesthesic filtering bleb: A surgical technique and case report.\",\"authors\":\"Elena Arias-García, Cristina Martinez-Gil, Marc Bautista-Cortiella, Gonzalo Roig-Ferreruela, Jose Vicente Piá-Ludeña, Aitor Lanzagorta-Aresti\",\"doi\":\"10.1177/11206721241304157\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>To present a novel surgical technique for the treatment of a steep-walled filtering bleb following an Ahmed glaucoma valve implant. The primary aim was to alleviate the patient's discomfort and address associated corneal thinning, complications that can arise from this condition.</p><p><strong>Methods: </strong>Case report and surgical technique. This case report describes a 29-year-old female who developed a dysesthesic filtering bleb following the implantation of a glaucoma drainage device. The employed surgical technique to address this complication involved the drainage of aqueous from the bleb using a 30-G needle, which effectively reduced its height. Subsequently, a compression suture was applied to maintain an appropriate bleb size.</p><p><strong>Results: </strong>With the presented surgical technique, the ultimate control of an overhigh filtering bleb associated to a glaucoma drainage device was possible. Following the procedure, the patient's symptoms and the corneal thinning linked to the bleb's excessive size were successfully managed. Furthermore, the anatomy of the filtering bleb was preserved, and an optimal intraocular pressure outcome was achieved.</p><p><strong>Conclusions: </strong>The removal of aqueous and the application of a compression suture are two surgical techniques traditionally used for managing the hypertensive phase of glaucoma drainage devices and for alleviating discomfort from blebs after classical filtering surgery, respectively. In the case presented, the combination of these two techniques effectively reduced the size of an excessively high filtering bleb associated with a glaucoma drainage device. This approach successfully resolved the patient's discomfort and corneal issues related to this complication.</p>\",\"PeriodicalId\":12000,\"journal\":{\"name\":\"European Journal of Ophthalmology\",\"volume\":\" \",\"pages\":\"11206721241304157\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-12-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11206721241304157\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11206721241304157","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

简介:介绍一种新的手术技术,用于治疗艾哈迈德青光眼瓣膜植入后的陡峭壁滤过泡。主要目的是减轻患者的不适和解决相关的角膜变薄,并发症可能从这种情况下产生。方法:病例报告和手术技巧。本病例报告描述了一位29岁的女性,她在植入青光眼引流装置后出现了感觉不良的滤过性水泡。采用外科技术来解决这一并发症,包括使用30g针从水泡中排出水,有效地降低了其高度。随后,加压缝合以保持适当的水泡大小。结果:采用所提出的手术技术,最终控制与青光眼引流装置相关的过高滤过泡是可能的。手术后,患者的症状和与水泡过大有关的角膜变薄得到了成功的控制。此外,滤过泡的解剖结构得以保留,并获得了最佳的眼压结果。结论:在青光眼引流装置的高血压期,传统的两种手术技术分别是水的去除和加压缝合的应用,以及减轻传统滤过手术后的水泡不适。在本病例中,这两种技术的结合有效地减少了与青光眼引流装置相关的过高滤过泡的大小。这种方法成功地解决了患者的不适和与此并发症相关的角膜问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Removal of aqueous humor and conjunctival compression sutures for a dysesthesic filtering bleb: A surgical technique and case report.

Introduction: To present a novel surgical technique for the treatment of a steep-walled filtering bleb following an Ahmed glaucoma valve implant. The primary aim was to alleviate the patient's discomfort and address associated corneal thinning, complications that can arise from this condition.

Methods: Case report and surgical technique. This case report describes a 29-year-old female who developed a dysesthesic filtering bleb following the implantation of a glaucoma drainage device. The employed surgical technique to address this complication involved the drainage of aqueous from the bleb using a 30-G needle, which effectively reduced its height. Subsequently, a compression suture was applied to maintain an appropriate bleb size.

Results: With the presented surgical technique, the ultimate control of an overhigh filtering bleb associated to a glaucoma drainage device was possible. Following the procedure, the patient's symptoms and the corneal thinning linked to the bleb's excessive size were successfully managed. Furthermore, the anatomy of the filtering bleb was preserved, and an optimal intraocular pressure outcome was achieved.

Conclusions: The removal of aqueous and the application of a compression suture are two surgical techniques traditionally used for managing the hypertensive phase of glaucoma drainage devices and for alleviating discomfort from blebs after classical filtering surgery, respectively. In the case presented, the combination of these two techniques effectively reduced the size of an excessively high filtering bleb associated with a glaucoma drainage device. This approach successfully resolved the patient's discomfort and corneal issues related to this complication.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
0.00%
发文量
372
审稿时长
3-8 weeks
期刊介绍: The European Journal of Ophthalmology was founded in 1991 and is issued in print bi-monthly. It publishes only peer-reviewed original research reporting clinical observations and laboratory investigations with clinical relevance focusing on new diagnostic and surgical techniques, instrument and therapy updates, results of clinical trials and research findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信