法语版视觉功能和角膜健康状况仪的验证及其与Fuchs内皮性角膜营养不良患者视力和眩光测量的相关性。

IF 1.9 3区 医学 Q2 OPHTHALMOLOGY
Cornea Pub Date : 2025-01-01 Epub Date: 2024-10-03 DOI:10.1097/ICO.0000000000003660
Guillaume A Mullie, Alejandro Juarez, Antoine Etcheverry, Paul Natchev, Nassima Taleb, Tanguy Boutin, Johanna Choremis, Michèle Mabon, Julia Talajic, Charles-Édouard Giguère, Isabelle Brunette
{"title":"法语版视觉功能和角膜健康状况仪的验证及其与Fuchs内皮性角膜营养不良患者视力和眩光测量的相关性。","authors":"Guillaume A Mullie, Alejandro Juarez, Antoine Etcheverry, Paul Natchev, Nassima Taleb, Tanguy Boutin, Johanna Choremis, Michèle Mabon, Julia Talajic, Charles-Édouard Giguère, Isabelle Brunette","doi":"10.1097/ICO.0000000000003660","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To validate a French version of the Visual Function and Corneal Health Status (V-FUCHS) instrument in Fuchs endothelial corneal dystrophy (FECD) and to correlate questionnaire scores with objective measurements of best-corrected visual acuity (BCVA) and intraocular straylight.</p><p><strong>Methods: </strong>The original V-FUCHS 15-item instrument was designed to assess VA and glare in patients with FECD. It was translated from English to French and back translated to English by independent translators. The questionnaire was administered on 2 occasions (4 weeks apart), and BCVA, modified Krachmer grade, and straylight were measured. Construct validity, internal consistency, test-retest reliability, and predictive validity were assessed.</p><p><strong>Results: </strong>A total of 159 subjects, aged 41 to 86 years, were prospectively recruited from July 2019 to October 2020 and classified into 6 groups: mild, moderate, or advanced FECD; unilateral or bilateral Descemet membrane endothelial keratoplasty for FECD; and healthy controls (n = 35). Construct validity was confirmed by item response theory model. Cronbach alpha demonstrated excellent internal consistency (VA: 0.91, glare: 0.88), and intraclass correlations showed good test-retest reliability (VA: 0.75 and glare: 0.82). Significant correlations were observed between both VA and glare factors and the modified Krachmer grade, BCVA, and straylight.</p><p><strong>Conclusions: </strong>The proposed French version of the V-FUCHS instrument provides a valid and reliable tool for the assessment of visual disability in patients with FECD. This questionnaire bridges the gap between self-reported FECD symptoms and objective clinical measurements, which may prove useful to optimize the timing of surgery and to assess postoperative improvement in symptoms.</p>","PeriodicalId":10710,"journal":{"name":"Cornea","volume":"44 1","pages":"64-72"},"PeriodicalIF":1.9000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of a French Version of the Visual Function and Corneal Health Status Instrument and Correlation With Vision and Glare Measurements in Fuchs Endothelial Corneal Dystrophy.\",\"authors\":\"Guillaume A Mullie, Alejandro Juarez, Antoine Etcheverry, Paul Natchev, Nassima Taleb, Tanguy Boutin, Johanna Choremis, Michèle Mabon, Julia Talajic, Charles-Édouard Giguère, Isabelle Brunette\",\"doi\":\"10.1097/ICO.0000000000003660\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To validate a French version of the Visual Function and Corneal Health Status (V-FUCHS) instrument in Fuchs endothelial corneal dystrophy (FECD) and to correlate questionnaire scores with objective measurements of best-corrected visual acuity (BCVA) and intraocular straylight.</p><p><strong>Methods: </strong>The original V-FUCHS 15-item instrument was designed to assess VA and glare in patients with FECD. It was translated from English to French and back translated to English by independent translators. The questionnaire was administered on 2 occasions (4 weeks apart), and BCVA, modified Krachmer grade, and straylight were measured. Construct validity, internal consistency, test-retest reliability, and predictive validity were assessed.</p><p><strong>Results: </strong>A total of 159 subjects, aged 41 to 86 years, were prospectively recruited from July 2019 to October 2020 and classified into 6 groups: mild, moderate, or advanced FECD; unilateral or bilateral Descemet membrane endothelial keratoplasty for FECD; and healthy controls (n = 35). Construct validity was confirmed by item response theory model. Cronbach alpha demonstrated excellent internal consistency (VA: 0.91, glare: 0.88), and intraclass correlations showed good test-retest reliability (VA: 0.75 and glare: 0.82). Significant correlations were observed between both VA and glare factors and the modified Krachmer grade, BCVA, and straylight.</p><p><strong>Conclusions: </strong>The proposed French version of the V-FUCHS instrument provides a valid and reliable tool for the assessment of visual disability in patients with FECD. This questionnaire bridges the gap between self-reported FECD symptoms and objective clinical measurements, which may prove useful to optimize the timing of surgery and to assess postoperative improvement in symptoms.</p>\",\"PeriodicalId\":10710,\"journal\":{\"name\":\"Cornea\",\"volume\":\"44 1\",\"pages\":\"64-72\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cornea\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/ICO.0000000000003660\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cornea","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICO.0000000000003660","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/3 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:验证法国版本的视觉功能和角膜健康状况(V-FUCHS)仪器在Fuchs内皮性角膜营养不良(FECD)中的应用,并将问卷评分与最佳矫正视力(BCVA)和眼内散光的客观测量相关联。方法:设计了原始的V-FUCHS 15项仪器来评估FECD患者的VA和眩光。它由英语翻译成法语,再由独立翻译人员翻译成英语。问卷共进行2次(间隔4周),测量BCVA、改良Krachmer评分、迷走光。评估构念效度、内部一致性、重测信度及预测效度。结果:2019年7月至2020年10月,共招募了159名受试者,年龄41至86岁,分为6组:轻度、中度或晚期FECD;单侧或双侧角膜内皮成形术治疗FECD;健康对照组(n = 35)。用项目反应理论模型验证构念效度。Cronbach alpha表现出良好的内部一致性(VA: 0.91,眩光:0.88),班级内相关表现出良好的重测信度(VA: 0.75,眩光:0.82)。VA和眩光因子与改良Krachmer等级、BCVA和杂散光之间存在显著相关。结论:拟议的法语版V-FUCHS仪器为FECD患者的视力障碍评估提供了有效和可靠的工具。该问卷弥合了自我报告的FECD症状和客观临床测量之间的差距,可能有助于优化手术时机和评估术后症状的改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validation of a French Version of the Visual Function and Corneal Health Status Instrument and Correlation With Vision and Glare Measurements in Fuchs Endothelial Corneal Dystrophy.

Purpose: To validate a French version of the Visual Function and Corneal Health Status (V-FUCHS) instrument in Fuchs endothelial corneal dystrophy (FECD) and to correlate questionnaire scores with objective measurements of best-corrected visual acuity (BCVA) and intraocular straylight.

Methods: The original V-FUCHS 15-item instrument was designed to assess VA and glare in patients with FECD. It was translated from English to French and back translated to English by independent translators. The questionnaire was administered on 2 occasions (4 weeks apart), and BCVA, modified Krachmer grade, and straylight were measured. Construct validity, internal consistency, test-retest reliability, and predictive validity were assessed.

Results: A total of 159 subjects, aged 41 to 86 years, were prospectively recruited from July 2019 to October 2020 and classified into 6 groups: mild, moderate, or advanced FECD; unilateral or bilateral Descemet membrane endothelial keratoplasty for FECD; and healthy controls (n = 35). Construct validity was confirmed by item response theory model. Cronbach alpha demonstrated excellent internal consistency (VA: 0.91, glare: 0.88), and intraclass correlations showed good test-retest reliability (VA: 0.75 and glare: 0.82). Significant correlations were observed between both VA and glare factors and the modified Krachmer grade, BCVA, and straylight.

Conclusions: The proposed French version of the V-FUCHS instrument provides a valid and reliable tool for the assessment of visual disability in patients with FECD. This questionnaire bridges the gap between self-reported FECD symptoms and objective clinical measurements, which may prove useful to optimize the timing of surgery and to assess postoperative improvement in symptoms.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cornea
Cornea 医学-眼科学
CiteScore
5.20
自引率
10.70%
发文量
354
审稿时长
3-6 weeks
期刊介绍: For corneal specialists and for all general ophthalmologists with an interest in this exciting subspecialty, Cornea brings together the latest clinical and basic research on the cornea and the anterior segment of the eye. Each volume is peer-reviewed by Cornea''s board of world-renowned experts and fully indexed in archival format. Your subscription brings you the latest developments in your field and a growing library of valuable professional references. Sponsored by The Cornea Society which was founded as the Castroviejo Cornea Society in 1975.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信