Icare HOME眼压计与Goldmann眼压计在饮水试验中评估眼压峰值的一致性。

Q2 Medicine
Carolina N Susanna, Fernanda N Susanna, Laura Goldfarb Cyrino, Renato Antunes Schiave Germano, Remo Susanna, Pradeep Y Ramulu, Marcelo Hatanaka
{"title":"Icare HOME眼压计与Goldmann眼压计在饮水试验中评估眼压峰值的一致性。","authors":"Carolina N Susanna, Fernanda N Susanna, Laura Goldfarb Cyrino, Renato Antunes Schiave Germano, Remo Susanna, Pradeep Y Ramulu, Marcelo Hatanaka","doi":"10.1016/j.ogla.2024.11.008","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the agreement between the ICare HOME tonometer and the Goldmann Applanation Tonometer (GAT) in assessing the peak intraocular pressure (IOP) during the water-drinking test (WDT).</p><p><strong>Design: </strong>Prospective cross-sectional study.</p><p><strong>Subjects: </strong>Seventy-nine eyes of 41 open-angle glaucoma patients were included in the study.</p><p><strong>Methods: </strong>All of the included patients underwent a training session provided by ophthalmologist specialists to use the ICare HOME tonometer. Then the IOP was first measured with the GAT (AT900; Haag-Streit) by a trained physician, immediately followed by ICare HOME tonometer (TA022, ICare Oy) measurement by the patient. Four measurements were taken with each device with 15-minute differences as established by the WDT.</p><p><strong>Main outcome measures: </strong>The agreement and degree of correlation of the peak IOP by both tonometers were assessed.</p><p><strong>Results: </strong>The agreement between the ICare HOME and GAT was high during the WDT: the intraclass correlation coefficient (r) between the 2 methods from basal to 45 minutes: 0.94 (P < 0.001), at basal: 0.91 (P < 0.001), at 15 minutes: 0.94 (P < 0.001), at 30 minutes: 0.94 (P < 0.001), at 45 minutes: 0.95 (P < 0.001), and for peak IOP: 0.94 (P < 0.001). There was no significant difference between peak IOP with the GAT and ICare HOME (18.3 ± 4.6 [10-33] and 18.5 ± 5.0 [0-33], respectively, P = 0.533), nor between the delta of fluctuation between basal and peak IOP with the GAT and ICare HOME (3.96 ± 3.22 and 4.54 ± 3.92, P = 0.054).</p><p><strong>Conclusions: </strong>Our study demonstrated a high agreement between the ICare HOME and the GAT during the WDT in a clinical environment with supervision.</p><p><strong>Financial disclosure(s): </strong>The authors have no proprietary or commercial interest in any materials discussed in this article.</p>","PeriodicalId":56368,"journal":{"name":"Ophthalmology. Glaucoma","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Agreement between the ICare HOME Tonometer and the Goldmann Applanation Tonometer in the Assessment of the Peak Intraocular Pressure in the Water-Drinking Test.\",\"authors\":\"Carolina N Susanna, Fernanda N Susanna, Laura Goldfarb Cyrino, Renato Antunes Schiave Germano, Remo Susanna, Pradeep Y Ramulu, Marcelo Hatanaka\",\"doi\":\"10.1016/j.ogla.2024.11.008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To investigate the agreement between the ICare HOME tonometer and the Goldmann Applanation Tonometer (GAT) in assessing the peak intraocular pressure (IOP) during the water-drinking test (WDT).</p><p><strong>Design: </strong>Prospective cross-sectional study.</p><p><strong>Subjects: </strong>Seventy-nine eyes of 41 open-angle glaucoma patients were included in the study.</p><p><strong>Methods: </strong>All of the included patients underwent a training session provided by ophthalmologist specialists to use the ICare HOME tonometer. Then the IOP was first measured with the GAT (AT900; Haag-Streit) by a trained physician, immediately followed by ICare HOME tonometer (TA022, ICare Oy) measurement by the patient. Four measurements were taken with each device with 15-minute differences as established by the WDT.</p><p><strong>Main outcome measures: </strong>The agreement and degree of correlation of the peak IOP by both tonometers were assessed.</p><p><strong>Results: </strong>The agreement between the ICare HOME and GAT was high during the WDT: the intraclass correlation coefficient (r) between the 2 methods from basal to 45 minutes: 0.94 (P < 0.001), at basal: 0.91 (P < 0.001), at 15 minutes: 0.94 (P < 0.001), at 30 minutes: 0.94 (P < 0.001), at 45 minutes: 0.95 (P < 0.001), and for peak IOP: 0.94 (P < 0.001). There was no significant difference between peak IOP with the GAT and ICare HOME (18.3 ± 4.6 [10-33] and 18.5 ± 5.0 [0-33], respectively, P = 0.533), nor between the delta of fluctuation between basal and peak IOP with the GAT and ICare HOME (3.96 ± 3.22 and 4.54 ± 3.92, P = 0.054).</p><p><strong>Conclusions: </strong>Our study demonstrated a high agreement between the ICare HOME and the GAT during the WDT in a clinical environment with supervision.</p><p><strong>Financial disclosure(s): </strong>The authors have no proprietary or commercial interest in any materials discussed in this article.</p>\",\"PeriodicalId\":56368,\"journal\":{\"name\":\"Ophthalmology. Glaucoma\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmology. Glaucoma\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1016/j.ogla.2024.11.008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmology. Glaucoma","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.ogla.2024.11.008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨Icare家用眼压计与Goldmann眼压计(GAT)在饮水试验(WDT)中评估眼压峰值的一致性。设计:前瞻性横断面研究。研究对象:41例开角型青光眼患者79只眼。方法:所有纳入的患者都接受了由眼科专家提供的使用Icare®家用眼压仪的培训课程。然后用Goldmann眼压计(AT900;Haag-Streit;由训练有素的医生(Köniz, suia)进行测量,紧接着由患者进行Icare®家用血压仪(TA022, Icare Oy, Vanda, Finland)测量。根据WDT确定,每个装置进行了四次测量,相差15分钟。主要观察指标:评估两种眼压计测量的峰值眼压的一致性和相关程度。结果:在WDT期间,iCare与Goldmann压血压计之间的一致性很高:两种方法在基线至45 min之间的类内相关系数(r)为0.94 (p < 0.001),在基线时为0.91 (p < 0.001),在15 min时为0.94 (p < 0.001),在30 min时为0.94 (p < 0.001),在45 min时为0.95 (p < 0.001),在IOP峰值时为0.94 (p < 0.001)。GAT和iCare的IOP峰值分别为18.3±4.6(10-33)和18.5±5.0(0-33),差异无统计学意义(p = 0.533); GAT和iCare的基础IOP与峰值的波动δ值分别为3.96±3.22和4.54±3.92,差异无统计学意义(p = 0.054)。结论:我们的研究表明,iCare HOME和Goldmann眼压计在临床环境监督下,在WDT期间具有很高的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Agreement between the ICare HOME Tonometer and the Goldmann Applanation Tonometer in the Assessment of the Peak Intraocular Pressure in the Water-Drinking Test.

Purpose: To investigate the agreement between the ICare HOME tonometer and the Goldmann Applanation Tonometer (GAT) in assessing the peak intraocular pressure (IOP) during the water-drinking test (WDT).

Design: Prospective cross-sectional study.

Subjects: Seventy-nine eyes of 41 open-angle glaucoma patients were included in the study.

Methods: All of the included patients underwent a training session provided by ophthalmologist specialists to use the ICare HOME tonometer. Then the IOP was first measured with the GAT (AT900; Haag-Streit) by a trained physician, immediately followed by ICare HOME tonometer (TA022, ICare Oy) measurement by the patient. Four measurements were taken with each device with 15-minute differences as established by the WDT.

Main outcome measures: The agreement and degree of correlation of the peak IOP by both tonometers were assessed.

Results: The agreement between the ICare HOME and GAT was high during the WDT: the intraclass correlation coefficient (r) between the 2 methods from basal to 45 minutes: 0.94 (P < 0.001), at basal: 0.91 (P < 0.001), at 15 minutes: 0.94 (P < 0.001), at 30 minutes: 0.94 (P < 0.001), at 45 minutes: 0.95 (P < 0.001), and for peak IOP: 0.94 (P < 0.001). There was no significant difference between peak IOP with the GAT and ICare HOME (18.3 ± 4.6 [10-33] and 18.5 ± 5.0 [0-33], respectively, P = 0.533), nor between the delta of fluctuation between basal and peak IOP with the GAT and ICare HOME (3.96 ± 3.22 and 4.54 ± 3.92, P = 0.054).

Conclusions: Our study demonstrated a high agreement between the ICare HOME and the GAT during the WDT in a clinical environment with supervision.

Financial disclosure(s): The authors have no proprietary or commercial interest in any materials discussed in this article.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ophthalmology. Glaucoma
Ophthalmology. Glaucoma Medicine-Medicine (all)
CiteScore
4.20
自引率
0.00%
发文量
140
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信