亚急性脑卒中患者行动研究臂测试的波兰语翻译、文化适应和初步验证。

IF 2.1 4区 医学 Q3 MEDICINE, RESEARCH & EXPERIMENTAL
Joanna Małecka, Magdalena Goliwąs, Katarzyna Adamczewska, Jacek Lewandowski, Dawid Łochyński
{"title":"亚急性脑卒中患者行动研究臂测试的波兰语翻译、文化适应和初步验证。","authors":"Joanna Małecka, Magdalena Goliwąs, Katarzyna Adamczewska, Jacek Lewandowski, Dawid Łochyński","doi":"10.17219/acem/191775","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In Poland, there are limited validated outcome measures to evaluate upper extremity function in stroke patients for clinical and research use. The Action Research Arm Test (ARAT) aims to assess functional performance of the upper extremities.</p><p><strong>Objectives: </strong>To translate and culturally adapt the original version of ARAT into Polish, and to determine its reliability and validity.</p><p><strong>Material and methods: </strong>A Polish version of ARAT (ARAT-PL) was developed using a forward-backward translation. The study then examined 60 patients with subacute stroke. Internal consistency (α), test-retest and inter-rater reliability (intra-class correlation (ICC), κ), standard error of measurement (SEM), minimal detectable change (MDC), and floor and ceiling effects were determined. The construct validity was evaluated using the method of hypothesis testing based on the results of correlations (rho) between subscale and total scores of the ARAT-PL and the upper and lower extremity section of the Fugl-Meyer Assessment (FMA-UE and FMA-LE).</p><p><strong>Results: </strong>The internal consistency of the total scores and subscale was excellent (α = 0.97-0.99). Test-retest and inter-rater reliability scores were almost perfect (κ = 0.85-1.0) and excellent for the total and subscale scores (ICC = 0.99-1). The SEM and MDC for the test-retest and inter-rater reliability were 0.479, 1.327 points and 0.335, 0.930 points, respectively. The ceiling effect amounted to 48%. The validity levels with respect to FMA-UE and FMA-LE were found to be high (rho ranging from 0.70 to 0.83) and moderate (rho ranging from 0.53 to 0.68), respectively.</p><p><strong>Conclusions: </strong>A Polish version of ARAT is a reliable and valid tool for assessing upper extremity function in subacute stroke patients in Poland. However, it appears to have a ceiling effect that limits differentiation of patients with mild upper limb impairment.</p>","PeriodicalId":7306,"journal":{"name":"Advances in Clinical and Experimental Medicine","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2024-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The translation into Polish, cultural adaptation, and initial validation of the Action Research Arm Test in subacute stroke patients.\",\"authors\":\"Joanna Małecka, Magdalena Goliwąs, Katarzyna Adamczewska, Jacek Lewandowski, Dawid Łochyński\",\"doi\":\"10.17219/acem/191775\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>In Poland, there are limited validated outcome measures to evaluate upper extremity function in stroke patients for clinical and research use. The Action Research Arm Test (ARAT) aims to assess functional performance of the upper extremities.</p><p><strong>Objectives: </strong>To translate and culturally adapt the original version of ARAT into Polish, and to determine its reliability and validity.</p><p><strong>Material and methods: </strong>A Polish version of ARAT (ARAT-PL) was developed using a forward-backward translation. The study then examined 60 patients with subacute stroke. Internal consistency (α), test-retest and inter-rater reliability (intra-class correlation (ICC), κ), standard error of measurement (SEM), minimal detectable change (MDC), and floor and ceiling effects were determined. The construct validity was evaluated using the method of hypothesis testing based on the results of correlations (rho) between subscale and total scores of the ARAT-PL and the upper and lower extremity section of the Fugl-Meyer Assessment (FMA-UE and FMA-LE).</p><p><strong>Results: </strong>The internal consistency of the total scores and subscale was excellent (α = 0.97-0.99). Test-retest and inter-rater reliability scores were almost perfect (κ = 0.85-1.0) and excellent for the total and subscale scores (ICC = 0.99-1). The SEM and MDC for the test-retest and inter-rater reliability were 0.479, 1.327 points and 0.335, 0.930 points, respectively. The ceiling effect amounted to 48%. The validity levels with respect to FMA-UE and FMA-LE were found to be high (rho ranging from 0.70 to 0.83) and moderate (rho ranging from 0.53 to 0.68), respectively.</p><p><strong>Conclusions: </strong>A Polish version of ARAT is a reliable and valid tool for assessing upper extremity function in subacute stroke patients in Poland. However, it appears to have a ceiling effect that limits differentiation of patients with mild upper limb impairment.</p>\",\"PeriodicalId\":7306,\"journal\":{\"name\":\"Advances in Clinical and Experimental Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Clinical and Experimental Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.17219/acem/191775\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Clinical and Experimental Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.17219/acem/191775","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:在波兰,用于临床和研究的评估脑卒中患者上肢功能的有效结果指标有限。动作研究臂测试(ARAT)旨在评估上肢的功能表现。目的:将原版本的ARAT翻译成波兰语并进行文化改编,并确定其信度和效度。材料和方法:波兰语版本的ARAT (ARAT- pl)是使用向前向后翻译开发的。该研究随后检查了60名亚急性中风患者。测定了内部一致性(α)、重测信度和评分者间信度(类内相关性(ICC)、κ)、测量标准误差(SEM)、最小可检测变化(MDC)以及下限和上限效应。根据ARAT-PL子量表和总分与Fugl-Meyer评估(FMA-UE和FMA-LE)上肢和下肢部分的相关系数(rho),采用假设检验的方法评估结构效度。结果:总分与量表内部一致性极好(α = 0.97 ~ 0.99)。重测信度和量表间信度得分几乎为完美(κ = 0.85-1.0),总量表和分量量表的信度得分为优秀(ICC = 0.99-1)。重测信度的SEM和MDC分别为0.479、1.327点和0.335、0.930点。上限效应达到48%。FMA-UE和FMA-LE的效度水平分别为高效度(rho为0.70 ~ 0.83)和中等效度(rho为0.53 ~ 0.68)。结论:波兰版ARAT是评估波兰亚急性脑卒中患者上肢功能的可靠和有效的工具。然而,它似乎具有天花板效应,限制了轻度上肢损伤患者的分化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The translation into Polish, cultural adaptation, and initial validation of the Action Research Arm Test in subacute stroke patients.

Background: In Poland, there are limited validated outcome measures to evaluate upper extremity function in stroke patients for clinical and research use. The Action Research Arm Test (ARAT) aims to assess functional performance of the upper extremities.

Objectives: To translate and culturally adapt the original version of ARAT into Polish, and to determine its reliability and validity.

Material and methods: A Polish version of ARAT (ARAT-PL) was developed using a forward-backward translation. The study then examined 60 patients with subacute stroke. Internal consistency (α), test-retest and inter-rater reliability (intra-class correlation (ICC), κ), standard error of measurement (SEM), minimal detectable change (MDC), and floor and ceiling effects were determined. The construct validity was evaluated using the method of hypothesis testing based on the results of correlations (rho) between subscale and total scores of the ARAT-PL and the upper and lower extremity section of the Fugl-Meyer Assessment (FMA-UE and FMA-LE).

Results: The internal consistency of the total scores and subscale was excellent (α = 0.97-0.99). Test-retest and inter-rater reliability scores were almost perfect (κ = 0.85-1.0) and excellent for the total and subscale scores (ICC = 0.99-1). The SEM and MDC for the test-retest and inter-rater reliability were 0.479, 1.327 points and 0.335, 0.930 points, respectively. The ceiling effect amounted to 48%. The validity levels with respect to FMA-UE and FMA-LE were found to be high (rho ranging from 0.70 to 0.83) and moderate (rho ranging from 0.53 to 0.68), respectively.

Conclusions: A Polish version of ARAT is a reliable and valid tool for assessing upper extremity function in subacute stroke patients in Poland. However, it appears to have a ceiling effect that limits differentiation of patients with mild upper limb impairment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Advances in Clinical and Experimental Medicine
Advances in Clinical and Experimental Medicine MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
3.70
自引率
4.80%
发文量
153
审稿时长
6-12 weeks
期刊介绍: Advances in Clinical and Experimental Medicine has been published by the Wroclaw Medical University since 1992. Establishing the medical journal was the idea of Prof. Bogumił Halawa, Chair of the Department of Cardiology, and was fully supported by the Rector of Wroclaw Medical University, Prof. Zbigniew Knapik. Prof. Halawa was also the first editor-in-chief, between 1992-1997. The journal, then entitled "Postępy Medycyny Klinicznej i Doświadczalnej", appeared quarterly. Prof. Leszek Paradowski was editor-in-chief from 1997-1999. In 1998 he initiated alterations in the profile and cover design of the journal which were accepted by the Editorial Board. The title was changed to Advances in Clinical and Experimental Medicine. Articles in English were welcomed. A number of outstanding representatives of medical science from Poland and abroad were invited to participate in the newly established International Editorial Staff. Prof. Antonina Harłozińska-Szmyrka was editor-in-chief in years 2000-2005, in years 2006-2007 once again prof. Leszek Paradowski and prof. Maria Podolak-Dawidziak was editor-in-chief in years 2008-2016. Since 2017 the editor-in chief is prof. Maciej Bagłaj. Since July 2005, original papers have been published only in English. Case reports are no longer accepted. The manuscripts are reviewed by two independent reviewers and a statistical reviewer, and English texts are proofread by a native speaker. The journal has been indexed in several databases: Scopus, Ulrich’sTM International Periodicals Directory, Index Copernicus and since 2007 in Thomson Reuters databases: Science Citation Index Expanded i Journal Citation Reports/Science Edition. In 2010 the journal obtained Impact Factor which is now 1.179 pts. Articles published in the journal are worth 15 points among Polish journals according to the Polish Committee for Scientific Research and 169.43 points according to the Index Copernicus. Since November 7, 2012, Advances in Clinical and Experimental Medicine has been indexed and included in National Library of Medicine’s MEDLINE database. English abstracts printed in the journal are included and searchable using PubMed http://www.ncbi.nlm.nih.gov/pubmed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信