博来霉素电硬化治疗低流量血管畸形的现行操作规程(COP)。

IF 2.1 4区 医学 Q3 ONCOLOGY
Radiology and Oncology Pub Date : 2024-11-28 eCollection Date: 2024-12-01 DOI:10.2478/raon-2024-0061
Tobian Muir, Walter A Wohlgemuth, Maja Cemazar, Giulia Bertino, Ales Groselj, Lakshmi A Ratnam, Ian McCafferty, Moritz Wildgruber, Bernhard Gebauer, Francesca de Terlizzi, Alessandro Zanasi, Gregor Sersa
{"title":"博来霉素电硬化治疗低流量血管畸形的现行操作规程(COP)。","authors":"Tobian Muir, Walter A Wohlgemuth, Maja Cemazar, Giulia Bertino, Ales Groselj, Lakshmi A Ratnam, Ian McCafferty, Moritz Wildgruber, Bernhard Gebauer, Francesca de Terlizzi, Alessandro Zanasi, Gregor Sersa","doi":"10.2478/raon-2024-0061","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Bleomycin ElectroScleroTherapy (BEST) is a new approach in the treatment of vascular malformations. After bleomycin is administered to the malformation, electric pulses are applied to the target area to enhance the effectiveness of bleomycin. The mode of action is comparable to the effect of electrochemotherapy on tumour vasculature. For the wider and safer use of BEST in the clinical treatment of low-flow vascular malformations, this Current Operating Procedure (COP) is being prepared. It is a proposal for the clinical standardisation of BEST using the Cliniporator<sup>®</sup> as the electrical pulse generator with its associated electrodes. The electrical parameters considered in this protocol are those validated by the European Standard Operating Procedures for Electrochemotherapy (ESOPE) with the Cliniporator<sup>®</sup>.</p><p><strong>Conclusions: </strong>General requirements are proposed, and, depending on the type of lesion, local skills and the availability of radiological equipment, two technical approaches of BEST are described based on ultrasound guided intervention or combined ultrasound and fluoroscopic guided intervention.</p>","PeriodicalId":21034,"journal":{"name":"Radiology and Oncology","volume":"58 4","pages":"469-479"},"PeriodicalIF":2.1000,"publicationDate":"2024-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11604259/pdf/","citationCount":"0","resultStr":"{\"title\":\"Current Operating Procedure (COP) for Bleomycin ElectroScleroTherapy (BEST) of low-flow vascular malformations.\",\"authors\":\"Tobian Muir, Walter A Wohlgemuth, Maja Cemazar, Giulia Bertino, Ales Groselj, Lakshmi A Ratnam, Ian McCafferty, Moritz Wildgruber, Bernhard Gebauer, Francesca de Terlizzi, Alessandro Zanasi, Gregor Sersa\",\"doi\":\"10.2478/raon-2024-0061\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Bleomycin ElectroScleroTherapy (BEST) is a new approach in the treatment of vascular malformations. After bleomycin is administered to the malformation, electric pulses are applied to the target area to enhance the effectiveness of bleomycin. The mode of action is comparable to the effect of electrochemotherapy on tumour vasculature. For the wider and safer use of BEST in the clinical treatment of low-flow vascular malformations, this Current Operating Procedure (COP) is being prepared. It is a proposal for the clinical standardisation of BEST using the Cliniporator<sup>®</sup> as the electrical pulse generator with its associated electrodes. The electrical parameters considered in this protocol are those validated by the European Standard Operating Procedures for Electrochemotherapy (ESOPE) with the Cliniporator<sup>®</sup>.</p><p><strong>Conclusions: </strong>General requirements are proposed, and, depending on the type of lesion, local skills and the availability of radiological equipment, two technical approaches of BEST are described based on ultrasound guided intervention or combined ultrasound and fluoroscopic guided intervention.</p>\",\"PeriodicalId\":21034,\"journal\":{\"name\":\"Radiology and Oncology\",\"volume\":\"58 4\",\"pages\":\"469-479\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-11-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11604259/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiology and Oncology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2478/raon-2024-0061\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology and Oncology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2478/raon-2024-0061","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:博来霉素电硬化疗法(BEST)是治疗血管畸形的新途径。博来霉素被施用于畸形后,电脉冲应用于目标区域,以提高博来霉素的有效性。其作用方式与化疗对肿瘤血管的作用相当。为了在临床治疗低流量血管畸形中更广泛、更安全地使用BEST,正在编写本现行操作规程(COP)。这是一项关于BEST临床标准化的建议,使用Cliniporator®作为电脉冲发生器及其相关电极。本方案中考虑的电气参数是通过使用Cliniporator®的欧洲电化疗标准操作程序(ESOPE)验证的。结论:提出了总体要求,并根据病变类型、局部技能和放射设备的可得性,描述了基于超声引导介入或超声与透视联合引导介入的两种BEST技术途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Current Operating Procedure (COP) for Bleomycin ElectroScleroTherapy (BEST) of low-flow vascular malformations.

Background: Bleomycin ElectroScleroTherapy (BEST) is a new approach in the treatment of vascular malformations. After bleomycin is administered to the malformation, electric pulses are applied to the target area to enhance the effectiveness of bleomycin. The mode of action is comparable to the effect of electrochemotherapy on tumour vasculature. For the wider and safer use of BEST in the clinical treatment of low-flow vascular malformations, this Current Operating Procedure (COP) is being prepared. It is a proposal for the clinical standardisation of BEST using the Cliniporator® as the electrical pulse generator with its associated electrodes. The electrical parameters considered in this protocol are those validated by the European Standard Operating Procedures for Electrochemotherapy (ESOPE) with the Cliniporator®.

Conclusions: General requirements are proposed, and, depending on the type of lesion, local skills and the availability of radiological equipment, two technical approaches of BEST are described based on ultrasound guided intervention or combined ultrasound and fluoroscopic guided intervention.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiology and Oncology
Radiology and Oncology ONCOLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
4.40
自引率
0.00%
发文量
42
审稿时长
>12 weeks
期刊介绍: Radiology and Oncology is a multidisciplinary journal devoted to the publishing original and high quality scientific papers and review articles, pertinent to diagnostic and interventional radiology, computerized tomography, magnetic resonance, ultrasound, nuclear medicine, radiotherapy, clinical and experimental oncology, radiobiology, medical physics and radiation protection. Therefore, the scope of the journal is to cover beside radiology the diagnostic and therapeutic aspects in oncology, which distinguishes it from other journals in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信