全身PET/MRI检测骨转移:序列诊断性能的比较。

IF 2.1 4区 医学 Q3 ONCOLOGY
Radiology and Oncology Pub Date : 2024-11-28 eCollection Date: 2024-12-01 DOI:10.2478/raon-2024-0062
Onur Levent Ulusoy, Sadık Server, Murat Yesilova, Nagihan İnan
{"title":"全身PET/MRI检测骨转移:序列诊断性能的比较。","authors":"Onur Levent Ulusoy, Sadık Server, Murat Yesilova, Nagihan İnan","doi":"10.2478/raon-2024-0062","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Whole-body positron emission tomography/magnetic resonance imaging (WB-PET/MRI) is increasingly used in the initial evaluation of oncology patients. The purpose of this study was to compare the diagnostic performance of WB MRI sequences, attenuation-corrected raw data positron-emission tomography (AC PET), and PET/MRI fused images to detect bone metastases.</p><p><strong>Patients and methods: </strong>We included 765 consecutive oncologic patients who received WB-PET/MRI from between January 2017 and September 2023. The presence of bone metastases was assessed using the individual sequences by two radiologists. Interobserver agreement was calculated. A receiver operating characteristic (ROC) analysis was performed to assess the performance of each individual sequence and fused images.</p><p><strong>Results: </strong>Interobserver agreement for the detection of bone metastases on all sequences ranged from good to very good. The reading of the combination of MRI sequences with PET images showed statistically significantly better performance than the reading of individual MRI sequences and PET component only. Contrast enhanced T1 W Volume-interpolated breath-hold examination (CE T1W VIBE) sequence superior to PET for the detection of bone metastasis, but the statistical significance was not as high as with T1W-PET and CE T1W-PET fused images. The highest performance was achieved by the fused CE T1W-PET images with sensitivity of 100%, specificity of 92%, PPV of 96%, and NPV of 100%.</p><p><strong>Conclusions: </strong>The combination of these CE T1W VIBE sequences with PET images have the highest diagnostic performance in detecting bone metastases in oncologic patients. This sequence should be integrated in WB-PET/MRI acquisitions for initial staging of cancer.</p>","PeriodicalId":21034,"journal":{"name":"Radiology and Oncology","volume":"58 4","pages":"494-500"},"PeriodicalIF":2.1000,"publicationDate":"2024-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11604270/pdf/","citationCount":"0","resultStr":"{\"title\":\"Whole-body PET/MRI to detect bone metastases: comparison of the diagnostic performance of the sequences.\",\"authors\":\"Onur Levent Ulusoy, Sadık Server, Murat Yesilova, Nagihan İnan\",\"doi\":\"10.2478/raon-2024-0062\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Whole-body positron emission tomography/magnetic resonance imaging (WB-PET/MRI) is increasingly used in the initial evaluation of oncology patients. The purpose of this study was to compare the diagnostic performance of WB MRI sequences, attenuation-corrected raw data positron-emission tomography (AC PET), and PET/MRI fused images to detect bone metastases.</p><p><strong>Patients and methods: </strong>We included 765 consecutive oncologic patients who received WB-PET/MRI from between January 2017 and September 2023. The presence of bone metastases was assessed using the individual sequences by two radiologists. Interobserver agreement was calculated. A receiver operating characteristic (ROC) analysis was performed to assess the performance of each individual sequence and fused images.</p><p><strong>Results: </strong>Interobserver agreement for the detection of bone metastases on all sequences ranged from good to very good. The reading of the combination of MRI sequences with PET images showed statistically significantly better performance than the reading of individual MRI sequences and PET component only. Contrast enhanced T1 W Volume-interpolated breath-hold examination (CE T1W VIBE) sequence superior to PET for the detection of bone metastasis, but the statistical significance was not as high as with T1W-PET and CE T1W-PET fused images. The highest performance was achieved by the fused CE T1W-PET images with sensitivity of 100%, specificity of 92%, PPV of 96%, and NPV of 100%.</p><p><strong>Conclusions: </strong>The combination of these CE T1W VIBE sequences with PET images have the highest diagnostic performance in detecting bone metastases in oncologic patients. This sequence should be integrated in WB-PET/MRI acquisitions for initial staging of cancer.</p>\",\"PeriodicalId\":21034,\"journal\":{\"name\":\"Radiology and Oncology\",\"volume\":\"58 4\",\"pages\":\"494-500\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-11-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11604270/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiology and Oncology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2478/raon-2024-0062\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology and Oncology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2478/raon-2024-0062","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:全身正电子发射断层扫描/磁共振成像(WB-PET/MRI)越来越多地用于肿瘤患者的初步评估。本研究的目的是比较WB MRI序列、衰减校正的原始数据正电子发射断层扫描(AC PET)和PET/MRI融合图像对骨转移的诊断性能。患者和方法:我们纳入了2017年1月至2023年9月期间连续接受WB-PET/MRI检查的765例肿瘤患者。两名放射科医生使用个体序列评估骨转移的存在。计算了观察员间的一致意见。进行接收者工作特征(ROC)分析以评估每个单独序列和融合图像的性能。结果:所有序列骨转移检测的观察者间一致性从好到非常好。MRI序列与PET图像组合的读数比单独的MRI序列和PET成分的读数具有统计学意义上的显著性。对比增强T1W Volume-interpolated breath-hold examination (CE T1W VIBE)序列对骨转移的检测优于PET,但统计学意义不如T1W-PET与CE T1W-PET融合成像。融合CE T1W-PET图像的灵敏度为100%,特异度为92%,PPV为96%,NPV为100%。结论:CE T1W VIBE序列结合PET影像对肿瘤患者骨转移的诊断效能最高。该序列应整合到WB-PET/MRI采集中,用于癌症的初始分期。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Whole-body PET/MRI to detect bone metastases: comparison of the diagnostic performance of the sequences.

Background: Whole-body positron emission tomography/magnetic resonance imaging (WB-PET/MRI) is increasingly used in the initial evaluation of oncology patients. The purpose of this study was to compare the diagnostic performance of WB MRI sequences, attenuation-corrected raw data positron-emission tomography (AC PET), and PET/MRI fused images to detect bone metastases.

Patients and methods: We included 765 consecutive oncologic patients who received WB-PET/MRI from between January 2017 and September 2023. The presence of bone metastases was assessed using the individual sequences by two radiologists. Interobserver agreement was calculated. A receiver operating characteristic (ROC) analysis was performed to assess the performance of each individual sequence and fused images.

Results: Interobserver agreement for the detection of bone metastases on all sequences ranged from good to very good. The reading of the combination of MRI sequences with PET images showed statistically significantly better performance than the reading of individual MRI sequences and PET component only. Contrast enhanced T1 W Volume-interpolated breath-hold examination (CE T1W VIBE) sequence superior to PET for the detection of bone metastasis, but the statistical significance was not as high as with T1W-PET and CE T1W-PET fused images. The highest performance was achieved by the fused CE T1W-PET images with sensitivity of 100%, specificity of 92%, PPV of 96%, and NPV of 100%.

Conclusions: The combination of these CE T1W VIBE sequences with PET images have the highest diagnostic performance in detecting bone metastases in oncologic patients. This sequence should be integrated in WB-PET/MRI acquisitions for initial staging of cancer.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiology and Oncology
Radiology and Oncology ONCOLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
4.40
自引率
0.00%
发文量
42
审稿时长
>12 weeks
期刊介绍: Radiology and Oncology is a multidisciplinary journal devoted to the publishing original and high quality scientific papers and review articles, pertinent to diagnostic and interventional radiology, computerized tomography, magnetic resonance, ultrasound, nuclear medicine, radiotherapy, clinical and experimental oncology, radiobiology, medical physics and radiation protection. Therefore, the scope of the journal is to cover beside radiology the diagnostic and therapeutic aspects in oncology, which distinguishes it from other journals in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信