无需术后头部定位的黄斑孔手术:一种覆盖颞内限制膜瓣的粘弹性装置注射技术。

IF 0.9 4区 医学 Q4 OPHTHALMOLOGY
Oğuzhan Saygılı, Sevim Ayça Seyyar
{"title":"无需术后头部定位的黄斑孔手术:一种覆盖颞内限制膜瓣的粘弹性装置注射技术。","authors":"Oğuzhan Saygılı, Sevim Ayça Seyyar","doi":"10.3928/23258160-20241015-01","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study was to describe a technique in which a dispersive viscoelastic device is injected under air onto and around the inverted temporal internal limiting membrane (ILM) flap to close the macular hole (MH) without the need for any postoperative head positioning. A temporal ILM flap was created in the patients. The created ILM flap was inverted over the MH using perfluorocarbon (PCFL) injection. Then, after a fluid-air exchange, careful PFCL-air exchange was performed. Under air, two- to three-disc diameters of viscoelastic device were injected over and around the inverted flap. No postoperative head position was recommended to any patient. In all 16 eyes treated with this approach, the MH was closed with a single procedure, and there were no intraoperative or postoperative complications. Injection of a viscoelastic device over the inverted ILM flap in MH surgery is an innovative approach that does not require any special postoperative head positioning. <b>[<i>Ophthalmic Surg Lasers Imaging Retina</i> 2024;55:XX-XX.]</b>.</p>","PeriodicalId":19679,"journal":{"name":"Ophthalmic surgery, lasers & imaging retina","volume":" ","pages":"1-3"},"PeriodicalIF":0.9000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Macular Hole Surgery Without Postoperative Head Positioning: A Technique of Viscoelastic Device Injection Covering the Temporal Internal Limiting Membrane Flap.\",\"authors\":\"Oğuzhan Saygılı, Sevim Ayça Seyyar\",\"doi\":\"10.3928/23258160-20241015-01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this study was to describe a technique in which a dispersive viscoelastic device is injected under air onto and around the inverted temporal internal limiting membrane (ILM) flap to close the macular hole (MH) without the need for any postoperative head positioning. A temporal ILM flap was created in the patients. The created ILM flap was inverted over the MH using perfluorocarbon (PCFL) injection. Then, after a fluid-air exchange, careful PFCL-air exchange was performed. Under air, two- to three-disc diameters of viscoelastic device were injected over and around the inverted flap. No postoperative head position was recommended to any patient. In all 16 eyes treated with this approach, the MH was closed with a single procedure, and there were no intraoperative or postoperative complications. Injection of a viscoelastic device over the inverted ILM flap in MH surgery is an innovative approach that does not require any special postoperative head positioning. <b>[<i>Ophthalmic Surg Lasers Imaging Retina</i> 2024;55:XX-XX.]</b>.</p>\",\"PeriodicalId\":19679,\"journal\":{\"name\":\"Ophthalmic surgery, lasers & imaging retina\",\"volume\":\" \",\"pages\":\"1-3\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmic surgery, lasers & imaging retina\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3928/23258160-20241015-01\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic surgery, lasers & imaging retina","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/23258160-20241015-01","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在描述一种技术,即在空气中向倒置的颞叶内缘膜(ILM)瓣及其周围注入分散性粘弹性装置,以关闭黄斑孔(MH),而无需术后头部定位。为患者制作了一个颞部ILM瓣。使用全氟碳化物(PCFL)注射将制作好的ILM瓣倒置在黄斑孔上。然后,在液体-空气交换后,进行仔细的 PFCL-空气交换。在空气中,将两到三盘直径的粘弹性装置注入倒置的皮瓣及其周围。没有向任何患者建议术后头部位置。在采用这种方法治疗的所有 16 只眼睛中,MH 只需一次手术即可闭合,术中和术后均未出现并发症。在倒置的ILM瓣上注射粘弹性装置用于MH手术是一种创新方法,术后不需要特殊的头部定位。[眼科手术激光成像视网膜2024;55:XX-XX]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Macular Hole Surgery Without Postoperative Head Positioning: A Technique of Viscoelastic Device Injection Covering the Temporal Internal Limiting Membrane Flap.

The purpose of this study was to describe a technique in which a dispersive viscoelastic device is injected under air onto and around the inverted temporal internal limiting membrane (ILM) flap to close the macular hole (MH) without the need for any postoperative head positioning. A temporal ILM flap was created in the patients. The created ILM flap was inverted over the MH using perfluorocarbon (PCFL) injection. Then, after a fluid-air exchange, careful PFCL-air exchange was performed. Under air, two- to three-disc diameters of viscoelastic device were injected over and around the inverted flap. No postoperative head position was recommended to any patient. In all 16 eyes treated with this approach, the MH was closed with a single procedure, and there were no intraoperative or postoperative complications. Injection of a viscoelastic device over the inverted ILM flap in MH surgery is an innovative approach that does not require any special postoperative head positioning. [Ophthalmic Surg Lasers Imaging Retina 2024;55:XX-XX.].

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
89
期刊介绍: OSLI Retina focuses exclusively on retinal diseases, surgery and pharmacotherapy. OSLI Retina will offer an expedited submission to publication effort of peer-reviewed clinical science and case report articles. The front of the journal offers practical clinical and practice management features and columns specific to retina specialists. In sum, readers will find important peer-reviewed retina articles and the latest findings in techniques and science, as well as informative business and practice management features in one journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信