Paul D. Zander, Florian Rubach, Alfredo Martínez-García
{"title":"通过气相色谱同位素比质谱法进行正烷烃 δD 和 δ13C 分析的大容量注入和标准物质评估。","authors":"Paul D. Zander, Florian Rubach, Alfredo Martínez-García","doi":"10.1002/rcm.9943","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Rationale</h3>\n \n <p>Compound-specific stable isotope analysis of hydrogen (δD) and carbon (δ<sup>13</sup>C) in organic compounds is a valuable tool in biogeochemical research. A key limitation of this method is the relatively large amount of sample required to achieve desirable precision.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>We developed a large-volume (20 μL) injection method that allows for high throughput analysis of less concentrated samples and tested it for δ<sup>13</sup>C and δD measurements of <i>n</i>-alkanes. We also conducted a comparison of reference standards and assessed several methods to normalize and correct <i>n</i>-alkane δD and δ13C measurements.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The mean precision of the δD method based on 233 environmental <i>n</i>-alkane samples (two to three replications per sample) is 4.0‰ (1σ, estimated from the weighted mean of the pooled unbiased standard deviations) and 0.46‰ (1σ) for δ<sup>13</sup>C from 37 environmental samples (two to three replications per sample). The evaluation of reference standards shows that the use of <i>n</i>-alkane standards with large offsets in δD values in adjacent <i>n</i>-alkane chains can lead to biases in measurement correction.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The large-volume injection method shows good reproducibility of δ<sup>13</sup>C and δD measurements of <i>n</i>-alkanes and reduces the required sample concentration by about 80%. We propose that for δD measurements, a reference standard set should be used in which each reference standard has a limited range of δD values and no adjacent <i>n</i>-alkane chains, to minimize memory effects.</p>\n </section>\n </div>","PeriodicalId":225,"journal":{"name":"Rapid Communications in Mass Spectrometry","volume":"39 3","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/rcm.9943","citationCount":"0","resultStr":"{\"title\":\"Large-Volume Injection and Assessment of Reference Standards for n-Alkane δD and δ13C Analysis via Gas Chromatography Isotope Ratio Mass Spectrometry\",\"authors\":\"Paul D. Zander, Florian Rubach, Alfredo Martínez-García\",\"doi\":\"10.1002/rcm.9943\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Rationale</h3>\\n \\n <p>Compound-specific stable isotope analysis of hydrogen (δD) and carbon (δ<sup>13</sup>C) in organic compounds is a valuable tool in biogeochemical research. A key limitation of this method is the relatively large amount of sample required to achieve desirable precision.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>We developed a large-volume (20 μL) injection method that allows for high throughput analysis of less concentrated samples and tested it for δ<sup>13</sup>C and δD measurements of <i>n</i>-alkanes. We also conducted a comparison of reference standards and assessed several methods to normalize and correct <i>n</i>-alkane δD and δ13C measurements.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>The mean precision of the δD method based on 233 environmental <i>n</i>-alkane samples (two to three replications per sample) is 4.0‰ (1σ, estimated from the weighted mean of the pooled unbiased standard deviations) and 0.46‰ (1σ) for δ<sup>13</sup>C from 37 environmental samples (two to three replications per sample). The evaluation of reference standards shows that the use of <i>n</i>-alkane standards with large offsets in δD values in adjacent <i>n</i>-alkane chains can lead to biases in measurement correction.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>The large-volume injection method shows good reproducibility of δ<sup>13</sup>C and δD measurements of <i>n</i>-alkanes and reduces the required sample concentration by about 80%. We propose that for δD measurements, a reference standard set should be used in which each reference standard has a limited range of δD values and no adjacent <i>n</i>-alkane chains, to minimize memory effects.</p>\\n </section>\\n </div>\",\"PeriodicalId\":225,\"journal\":{\"name\":\"Rapid Communications in Mass Spectrometry\",\"volume\":\"39 3\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/rcm.9943\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Rapid Communications in Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9943\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rapid Communications in Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9943","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Large-Volume Injection and Assessment of Reference Standards for n-Alkane δD and δ13C Analysis via Gas Chromatography Isotope Ratio Mass Spectrometry
Rationale
Compound-specific stable isotope analysis of hydrogen (δD) and carbon (δ13C) in organic compounds is a valuable tool in biogeochemical research. A key limitation of this method is the relatively large amount of sample required to achieve desirable precision.
Methods
We developed a large-volume (20 μL) injection method that allows for high throughput analysis of less concentrated samples and tested it for δ13C and δD measurements of n-alkanes. We also conducted a comparison of reference standards and assessed several methods to normalize and correct n-alkane δD and δ13C measurements.
Results
The mean precision of the δD method based on 233 environmental n-alkane samples (two to three replications per sample) is 4.0‰ (1σ, estimated from the weighted mean of the pooled unbiased standard deviations) and 0.46‰ (1σ) for δ13C from 37 environmental samples (two to three replications per sample). The evaluation of reference standards shows that the use of n-alkane standards with large offsets in δD values in adjacent n-alkane chains can lead to biases in measurement correction.
Conclusions
The large-volume injection method shows good reproducibility of δ13C and δD measurements of n-alkanes and reduces the required sample concentration by about 80%. We propose that for δD measurements, a reference standard set should be used in which each reference standard has a limited range of δD values and no adjacent n-alkane chains, to minimize memory effects.
期刊介绍:
Rapid Communications in Mass Spectrometry is a journal whose aim is the rapid publication of original research results and ideas on all aspects of the science of gas-phase ions; it covers all the associated scientific disciplines. There is no formal limit on paper length ("rapid" is not synonymous with "brief"), but papers should be of a length that is commensurate with the importance and complexity of the results being reported. Contributions may be theoretical or practical in nature; they may deal with methods, techniques and applications, or with the interpretation of results; they may cover any area in science that depends directly on measurements made upon gaseous ions or that is associated with such measurements.